Volumn 53, Issue 5, 2006, Pages 855-864

Comparison of Doppler ultrasound and direct electrocardiography acquisition techniques for quantification of fetal heart rate variability

Author keywords

Doppler ultrasound; Fetal electrocardiogram; Fetal heart rate; Fetal monitoring

Indexed keywords

DOPPLER ULTRASOUND; FETAL ELECTROCARDIOGRAM; FETAL HEART RATE; FETAL HEART RATE (FHR) VARIABILITY;

EID: 33646371265     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2005.863945     Document Type: Article
Times cited : (76)

References (30)
  • 1
    • 0343445373 scopus 로고
    • Instrumentation of fetal heart rate and fetal electrocardiography. II. A vaginal electrode
    • E. H. Hon, "Instrumentation of fetal heart rate and fetal electrocardiography. II. A vaginal electrode," Am. J. Obstet. Gynecol., vol. 86, pp. 772-778, 1963.
    • (1963) Am. J. Obstet. Gynecol. , vol.86 , pp. 772-778
    • Hon, E.H.1
  • 3
    • 0021934263 scopus 로고
    • Autocorrelation techniques in fetal monitoring
    • M. Y. Divon, "Autocorrelation techniques in fetal monitoring," Am. J. Obstet. Gynecol., vol. 151, pp. 2-6, 1985.
    • (1985) Am. J. Obstet. Gynecol. , vol.151 , pp. 2-6
    • Divon, M.Y.1
  • 5
    • 84904355611 scopus 로고    scopus 로고
    • Analysis of nonstationarities in fetal heart rate signal: Inconsistency measures of baselines using acceleration/deceleration patterns
    • Paris, France
    • J. Jezewski, K. Horoba, A. Gacek, J. Wrobel, A. Matonia, and T. Kupka, "Analysis of nonstationarities in fetal heart rate signal: inconsistency measures of baselines using acceleration/deceleration patterns," in Proc. 7th ISSPA, Paris, France, 2003, pp. 34-38.
    • (2003) Proc. 7th ISSPA , pp. 34-38
    • Jezewski, J.1    Horoba, K.2    Gacek, A.3    Wrobel, J.4    Matonia, A.5    Kupka, T.6
  • 6
    • 0036911661 scopus 로고    scopus 로고
    • Fetal heart rate variability: Clinical experts versus computerized system interpretation
    • Huston, TX
    • J. Jezewski, J. Wrobel, K. Horoba, A. Gacek, and J. Sikora, "Fetal heart rate variability: clinical experts versus computerized system interpretation," in Proc. 24th IEEE EMBS Int. Conf., Huston, TX, 2002, pp. 1617-1618.
    • (2002) Proc. 24th IEEE EMBS Int. Conf. , pp. 1617-1618
    • Jezewski, J.1    Wrobel, J.2    Horoba, K.3    Gacek, A.4    Sikora, J.5
  • 7
    • 0018928795 scopus 로고
    • Analysis of heart rate and beat-to-beat variability: Interval difference index
    • H. P. van Geijn, "Analysis of heart rate and beat-to-beat variability: interval difference index," Am. J. Obstet. Gynecol., vol. 138, pp. 246-252, 1980.
    • (1980) Am. J. Obstet. Gynecol. , vol.138 , pp. 246-252
    • Van Geijn, H.P.1
  • 8
    • 0027839957 scopus 로고
    • Fetal monitoring with automated analysis of cardiotocogram: The KOMPOR system
    • San Diego, CA
    • J. Jezewski and J. Wrobel, "Fetal monitoring with automated analysis of cardiotocogram: the KOMPOR system," in Proc. 15th IEEE EMBS Int. Conf., San Diego, CA, 1993, pp. 638-639.
    • (1993) Proc. 15th IEEE EMBS Int. Conf. , pp. 638-639
    • Jezewski, J.1    Wrobel, J.2
  • 9
    • 0023217615 scopus 로고
    • Fetal heart variability indices and the accuracy of variability measurements
    • T. Kubo, J. Inaba, S. Shigemitsu, and T. Akatsuka, "Fetal heart variability indices and the accuracy of variability measurements," Am. J. Perinat., vol. 4, pp. 179-186, 1987.
    • (1987) Am. J. Perinat. , vol.4 , pp. 179-186
    • Kubo, T.1    Inaba, J.2    Shigemitsu, S.3    Akatsuka, T.4
  • 10
    • 11044228706 scopus 로고    scopus 로고
    • Monitoring of mechanical and electrical activity of fetal heart: Determination of the FHR
    • J. Jezewski et al., "Monitoring of mechanical and electrical activity of fetal heart: determination of the FHR," Arch. Perinat. Med., vol. 8, pp. 33-39, 2002.
    • (2002) Arch. Perinat. Med. , vol.8 , pp. 33-39
    • Jezewski, J.1
  • 11
    • 0019948988 scopus 로고
    • A comparison of two fetal heart rate ultrasound detector systems
    • G. W. Lawson, G. S. Dawes, and C. W. G. Redman, "A comparison of two fetal heart rate ultrasound detector systems," Am. J. Obstet. Gynecol., vol. 143, pp. 840-842, 1982.
    • (1982) Am. J. Obstet. Gynecol. , vol.143 , pp. 840-842
    • Lawson, G.W.1    Dawes, G.S.2    Redman, C.W.G.3
  • 12
    • 0021055986 scopus 로고
    • A comparison of ultrasound (with autocorrelation) and direct electrocardiogram fetal heart rate detector systems
    • G. W. Lawson, R. Belcher, G. S. Dawes, and C. W. G. Redman, "A comparison of ultrasound (with autocorrelation) and direct electrocardiogram fetal heart rate detector systems," Am. J. Obstet. Gynecol., vol. 147, pp. 721-722, 1983.
    • (1983) Am. J. Obstet. Gynecol. , vol.147 , pp. 721-722
    • Lawson, G.W.1    Belcher, R.2    Dawes, G.S.3    Redman, C.W.G.4
  • 13
    • 0022588174 scopus 로고
    • The indirectly obtained fetal heart rate: Comparison of first- and second-generation electronic fetal monitors
    • F. H. Boehm and L. M. Fields, "The indirectly obtained fetal heart rate: comparison of first- and second-generation electronic fetal monitors," Am. J. Obstet. Gynecol., vol. 155, pp. 10-14, 1986.
    • (1986) Am. J. Obstet. Gynecol. , vol.155 , pp. 10-14
    • Boehm, F.H.1    Fields, L.M.2
  • 14
    • 4944221672 scopus 로고    scopus 로고
    • Instrumentation for fetal monitoring - Improvement in Doppler ultrasound technology
    • J. Jezewski, J. Wrobel, K. Horoba, and A. Gacek, "Instrumentation for fetal monitoring - improvement in Doppler ultrasound technology," J. Med. Inf. Technol., vol. 2, pp. 17-26, 2001.
    • (2001) J. Med. Inf. Technol. , vol.2 , pp. 17-26
    • Jezewski, J.1    Wrobel, J.2    Horoba, K.3    Gacek, A.4
  • 15
    • 0020137893 scopus 로고
    • Improvement in Doppler ultrasound human foetal heart rate records by signal correlation
    • D. L. Tuck, "Improvement in Doppler ultrasound human foetal heart rate records by signal correlation," Med. Biol. Eng. Comput., vol. 20, pp. 357-360, 1982.
    • (1982) Med. Biol. Eng. Comput. , vol.20 , pp. 357-360
    • Tuck, D.L.1
  • 16
    • 0019481056 scopus 로고
    • Numerical analysis of the human fetal heart rate: The quality of ultrasound records
    • G. S. Dawes, G. H. A. Visser, J. D. S. Goodman, and C. W. G. Redman, "Numerical analysis of the human fetal heart rate: the quality of ultrasound records," Am. J. Obstet. Gynecol., vol. 141, pp. 43-52, 1981.
    • (1981) Am. J. Obstet. Gynecol. , vol.141 , pp. 43-52
    • Dawes, G.S.1    Visser, G.H.A.2    Goodman, J.D.S.3    Redman, C.W.G.4
  • 17
    • 0023223452 scopus 로고
    • The influence of signal loss on the comparison between computer analysis of the fetal heart rate in labor using pulsed Doppler ultrasound (with autocorrelation) and simultaneous scalp electrocardiogram
    • J. A. D. Spencer, R. D. Belcher, and R. D. Dawes, "The influence of signal loss on the comparison between computer analysis of the fetal heart rate in labor using pulsed Doppler ultrasound (with autocorrelation) and simultaneous scalp electrocardiogram," Eur. J. Obstet. Gynecol. Reprod. Biol., vol. 25, pp. 29-34, 1987.
    • (1987) Eur. J. Obstet. Gynecol. Reprod. Biol. , vol.25 , pp. 29-34
    • Spencer, J.A.D.1    Belcher, R.D.2    Dawes, R.D.3
  • 21
    • 2342591420 scopus 로고    scopus 로고
    • Beat-to-beat detection of fetal heart rate: Doppler ultrasound cardiotocography compared to direct ECG cardiotocography in time and frequency domain
    • C. H. L. Peters, E. D. M. ten Broeke, P. Andriessen, B. Vermeulen, R. C. M. Berendsen, P. F. F. Wijn, and S. G. Oei, "Beat-to-beat detection of fetal heart rate: Doppler ultrasound cardiotocography compared to direct ECG cardiotocography in time and frequency domain," Physiol. Measur., vol. 25, pp. 585-593, 2004.
    • (2004) Physiol. Measur. , vol.25 , pp. 585-593
    • Peters, C.H.L.1    Ten Broeke, E.D.M.2    Andriessen, P.3    Vermeulen, B.4    Berendsen, R.C.M.5    Wijn, P.F.F.6    Oei, S.G.7
  • 22
    • 0037297193 scopus 로고    scopus 로고
    • Real-time signal processing for fetal heart rate monitoring
    • Feb.
    • M. I. Ibrahimy, F. Ahmed, M. A. Mohd Ali, and E. Zahedi, "Real-time signal processing for fetal heart rate monitoring," IEEE Trans. Biomed. Eng., vol. 50, no. 2, pp. 258-262, Feb. 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.2 , pp. 258-262
    • Ibrahimy, M.I.1    Ahmed, F.2    Mohd Ali, M.A.3    Zahedi, E.4
  • 23
    • 85004893092 scopus 로고
    • Antenatal measurement of beat-to-beat fetal heart rate variation: Accuracy of the Hewlett-Packard ultrasound autocorrelation technique
    • Memphis, TN
    • A. J. Murrills, T. H. Wilmshurst, and T. Wheeler, "Antenatal measurement of beat-to-beat fetal heart rate variation: accuracy of the Hewlett-Packard ultrasound autocorrelation technique," in Proc. Fetal Physiological Measurement, Memphis, TN, 1986, pp. 36-14.
    • (1986) Proc. Fetal Physiological Measurement , pp. 36-114
    • Murrills, A.J.1    Wilmshurst, T.H.2    Wheeler, T.3
  • 24
    • 33646341463 scopus 로고    scopus 로고
    • Monitoring of mechanical and electrical activity of fetal heart: The nature of signals
    • J. Jezewski et al., "Monitoring of mechanical and electrical activity of fetal heart: the nature of signals," Arch. Perinat. Med., vol. 8, pp. 40-16, 2002.
    • (2002) Arch. Perinat. Med. , vol.8 , pp. 40-116
    • Jezewski, J.1
  • 26
    • 0015593615 scopus 로고
    • Quantification of fetal heart rate beat-to-beat interval differences
    • S. Y. Yeh, A. Forsythe, and E. H. Hon, "Quantification of fetal heart rate beat-to-beat interval differences," J. Obstet. Gynecol., vol. 41, pp. 355-363, 1973.
    • (1973) J. Obstet. Gynecol. , vol.41 , pp. 355-363
    • Yeh, S.Y.1    Forsythe, A.2    Hon, E.H.3
  • 27
    • 0018362206 scopus 로고
    • Fetal heart rate variability: An approach to automated assessment
    • J. R. Huey, R. H. Paul, A. A. Hadjiev, J. Jilek, and E. H. Hon, "Fetal heart rate variability: An approach to automated assessment," Am. J. Obstet. Gynecol., vol. 134, pp. 691-695, 1979.
    • (1979) Am. J. Obstet. Gynecol. , vol.134 , pp. 691-695
    • Huey, J.R.1    Paul, R.H.2    Hadjiev, A.A.3    Jilek, J.4    Hon, E.H.5
  • 28
    • 0017350610 scopus 로고
    • Diurnal respiratory and other rhythms of fetal heart rate in lambs
    • K. J. Dalton, G. S. Dawes, and J. E. Patrick, "Diurnal respiratory and other rhythms of fetal heart rate in lambs," Am. J. Obstet. Gynecol., vol. 127, pp. 414-424, 1977.
    • (1977) Am. J. Obstet. Gynecol. , vol.127 , pp. 414-424
    • Dalton, K.J.1    Dawes, G.S.2    Patrick, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.