메뉴 건너뛰기




Volumn 18, Issue 2, 2007, Pages 139-143

Prosthetic laboratory influence on the vertical misfit at the implant/UCLA abutment interface

Author keywords

Dental implants; Denture fitting; Implant supported dentures

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; RESIN;

EID: 59649106913     PISSN: 01036440     EISSN: 18064760     Source Type: Journal    
DOI: 10.1590/s0103-64402007000200010     Document Type: Article
Times cited : (26)

References (20)
  • 2
    • 0030309144 scopus 로고    scopus 로고
    • An overview of Bränemark System® restorative options
    • Lewis SG. An overview of Bränemark System® restorative options. J Esthet Dent 1996;8 Suppl: 3-44.
    • (1996) J Esthet Dent , vol.8 , Issue.SUPPL. , pp. 3-44
    • Lewis, S.G.1
  • 5
    • 0028522448 scopus 로고
    • A new method to routinely achieve passive fit of ceramometal prostheses over Bränemark osseointegrated implants: A two-year report
    • Aparicio C. A new method to routinely achieve passive fit of ceramometal prostheses over Bränemark osseointegrated implants: a two-year report. Int J Periodontics Restorative Dent 1994;14:405-419.
    • (1994) Int J Periodontics Restorative Dent , vol.14 , pp. 405-419
    • Aparicio, C.1
  • 6
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9:169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 7
    • 0030635617 scopus 로고    scopus 로고
    • Cement-retained versus screw-retainedimplant restorations: Achieving optimal occlusion and esthetics in implant dentistry
    • Hebel KS, Gajjar RC. Cement-retained versus screw-retainedimplant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent 1997;77:28-35.
    • (1997) J Prosthet Dent , vol.77 , pp. 28-35
    • Hebel, K.S.1    Gajjar, R.C.2
  • 10
    • 0031301642 scopus 로고    scopus 로고
    • Fit of implant frameworks fabricated by different techniques
    • Riedy SJ, Lang BR, Lang BE. Fit of implant frameworks fabricated by different techniques. J Prosthet Dent 1997;78:596-604.
    • (1997) J Prosthet Dent , vol.78 , pp. 596-604
    • Riedy, S.J.1    Lang, B.R.2    Lang, B.E.3
  • 12
    • 0033113639 scopus 로고    scopus 로고
    • Characterization of the interface between prefabricated gold copings and cast dental alloy in implant restorations
    • Carotenuto G, Palumbo M, Zarone F, Nicolais L. Characterization of the interface between prefabricated gold copings and cast dental alloy in implant restorations. Clin Oral Implants Res 1999;10:131-138.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 131-138
    • Carotenuto, G.1    Palumbo, M.2    Zarone, F.3    Nicolais, L.4
  • 13
    • 0142024931 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: A critical review
    • Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;18:719-728.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 719-728
    • Michalakis, K.X.1    Hirayama, H.2    Garefis, P.D.3
  • 15
    • 0032617145 scopus 로고    scopus 로고
    • Microleakage at the abutment-implant interface of osseointegrated implants: A comparative study
    • Gross M, Abramovich I, Weiss EI. Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants 1999;14:94-100.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 94-100
    • Gross, M.1    Abramovich, I.2    Weiss, E.I.3
  • 16
    • 77955628268 scopus 로고    scopus 로고
    • Fit microscope evaluation between implant and gold UCLA abutments and Teflon UCLA, casting in titanium and nickel-chromium-titanium
    • Carvalho MCA, Bondioli IR, Costa EMV, Nishioka RS, Bottino MA, Neisser MP. Fit microscope evaluation between implant and gold UCLA abutments and Teflon UCLA, casting in titanium and nickel-chromium-titanium. In vitro study. BCI 2002;9:105-110.
    • (2002) In vitro study. BCI , vol.9 , pp. 105-110
    • Carvalho, M.C.A.1    Bondioli, I.R.2    Costa, E.M.V.3    Nishioka, R.S.4    Bottino, M.A.5    Neisser, M.P.6
  • 17
    • 77955621509 scopus 로고    scopus 로고
    • Comparative study on the abutment/implant fit of seven differents systems
    • Neves FD, Panzeri H, Fernandes Neto AJ, Prado RA. Comparative study on the abutment/implant fit of seven differents systems. J Dent Res 2001;80:1031-1031.
    • (2001) J Dent Res , vol.80 , pp. 1031-1031
    • Neves, F.D.1    Panzeri, H.2    Fernandes, N.A.J.3    Prado, R.A.4
  • 18
    • 77955619646 scopus 로고    scopus 로고
    • Laboratory procedures influence in the implant/UCLA abutment fit - pilot study
    • Silveira Júnior CD, Fernandes Neto AJ, Neves FD, Franco SD, Mendonça G. Laboratory procedures influence in the implant/UCLA abutment fit - pilot study. PCL 2002;4:392-400.
    • (2002) PCL , vol.4 , pp. 392-400
    • Silveira, J.C.D.1    Fernandes, N.A.J.2    Neves, F.D.3    Franco, S.D.4    Mendonça, G.5
  • 20
    • 0002013674 scopus 로고
    • Introduction in Osseointegration
    • Brånemark PI., Zarb GA, Albrektsson T (Editors). Chicago: Quintessence Books
    • Brånemark PI, Zarb GA, Albrektsson T. Introduction in Osseointegration. In: Osseointegration in clinical dentistry. Brånemark PI., Zarb GA, Albrektsson T (Editors). Chicago: Quintessence Books; 1985.
    • (1985) Osseointegration in Clinical Dentistry
    • Brånemark, P.I.1    Zarb, G.A.2    Albrektsson, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.