메뉴 건너뛰기




Volumn 16, Issue 3, 2009, Pages 363-373

Ultra-low Dose Lung CT Perfusion Regularized by a Previous Scan

Author keywords

diffusion based postfiltering; Dose reduction; lung CT perfusion; previous scan regularized reconstruction; PSRR; ultra low dose

Indexed keywords

ALGORITHM; ANIMAL EXPERIMENT; ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; IMAGE QUALITY; IMAGE RECONSTRUCTION; LUNG FUNCTION; LUNG PERFUSION; NONHUMAN; PRIORITY JOURNAL; RADIATION DOSE; SHEEP;

EID: 59449097598     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2008.09.003     Document Type: Article
Times cited : (64)

References (24)
  • 1
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner D., Elliston C., Hall E., and Berdon W. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176 (2001) 289-296
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 289-296
    • Brenner, D.1    Elliston, C.2    Hall, E.3    Berdon, W.4
  • 2
    • 0842348097 scopus 로고    scopus 로고
    • Risk of cancer from diagnostic x-rays: estimates for the UK and 14 other countries
    • Berrington de González A., and Darby S. Risk of cancer from diagnostic x-rays: estimates for the UK and 14 other countries. Lancet 363 (2004) 345-351
    • (2004) Lancet , vol.363 , pp. 345-351
    • Berrington de González, A.1    Darby, S.2
  • 3
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography-an increasing source of radiation exposure
    • Brenner D.J., and Hall E.J. Computed tomography-an increasing source of radiation exposure. N Engl J Med 357 (2007) 2277-2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 4
    • 0042845953 scopus 로고    scopus 로고
    • National conference on dose reduction in computed tomography, emphasis on pediatrics
    • Linton O.W., and Mattler Jr. F.A. National conference on dose reduction in computed tomography, emphasis on pediatrics. AJR Am J Roentgenol 181 (2003) 321-329
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 321-329
    • Linton, O.W.1    Mattler Jr., F.A.2
  • 6
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation
    • Jakobs T.F., Becker C.R., Ohnesorge B., et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12 (2002) 1081-1086
    • (2002) Eur Radiol , vol.12 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3
  • 7
    • 33645750684 scopus 로고    scopus 로고
    • Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation
    • Goo H.W., and Suh D.S. Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation. Pediatr Radiol 36 (2006) 344-351
    • (2006) Pediatr Radiol , vol.36 , pp. 344-351
    • Goo, H.W.1    Suh, D.S.2
  • 8
    • 37549035028 scopus 로고    scopus 로고
    • Iterative projection reconstruction of time-resolved images using highly-constrained back-projection (HYPR)
    • O'Halloran R.L., Wen Z., Holmes J.H., and Fain S.B. Iterative projection reconstruction of time-resolved images using highly-constrained back-projection (HYPR). Magn Reson Med 59 (2008) 132-139
    • (2008) Magn Reson Med , vol.59 , pp. 132-139
    • O'Halloran, R.L.1    Wen, Z.2    Holmes, J.H.3    Fain, S.B.4
  • 9
    • 43149121836 scopus 로고    scopus 로고
    • An acquisition and image reconstruction scheme for reduced x-ray exposure dynamic 3D CTA. In: Medical imaging 2008: proceedings of SPIE
    • Supanich M., Rowley H., Turk A., Speidel M., Pulfer K., et al. An acquisition and image reconstruction scheme for reduced x-ray exposure dynamic 3D CTA. In: Medical imaging 2008: proceedings of SPIE. Bellingham, WA: SPIE (2008)
    • (2008) Bellingham, WA: SPIE
    • Supanich, M.1    Rowley, H.2    Turk, A.3    Speidel, M.4    Pulfer, K.5
  • 10
    • 33750611449 scopus 로고    scopus 로고
    • Low-dose, large-angled cone-beam helical CT data reconstruction using algebraic reconstruction techniques
    • Carvalho B.A., and Herman G.T. Low-dose, large-angled cone-beam helical CT data reconstruction using algebraic reconstruction techniques. Image Vision Comput 25 (2007) 78-94
    • (2007) Image Vision Comput , vol.25 , pp. 78-94
    • Carvalho, B.A.1    Herman, G.T.2
  • 11
    • 21144458117 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram smoothing for low-dose CT
    • La Riviere P.J. Penalized-likelihood sinogram smoothing for low-dose CT. Med Phys 32 (2005) 1676-1683
    • (2005) Med Phys , vol.32 , pp. 1676-1683
    • La Riviere, P.J.1
  • 12
    • 0036703579 scopus 로고    scopus 로고
    • A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging
    • Wang G., Zhao S.Y., and Heuscher D. A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging. Med Phys 29 (2002) 1807-1822
    • (2002) Med Phys , vol.29 , pp. 1807-1822
    • Wang, G.1    Zhao, S.Y.2    Heuscher, D.3
  • 13
    • 0032414773 scopus 로고    scopus 로고
    • Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • Kachelriess M., and Kalender W.A. Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys 25 (1998) 2417-2431
    • (1998) Med Phys , vol.25 , pp. 2417-2431
    • Kachelriess, M.1    Kalender, W.A.2
  • 14
    • 4544351987 scopus 로고    scopus 로고
    • A two-step Hilbert transform method for 2D image reconstruction
    • Noo F., Clackdoyle R., and Pack J.D. A two-step Hilbert transform method for 2D image reconstruction. Phys Med Biol 49 (2004) 3903-3923
    • (2004) Phys Med Biol , vol.49 , pp. 3903-3923
    • Noo, F.1    Clackdoyle, R.2    Pack, J.D.3
  • 15
    • 33746617610 scopus 로고    scopus 로고
    • Data consistency based translational motion artifact reduction in fan-beam CT
    • Yu H., Wei Y., Hsieh J., and Wang G. Data consistency based translational motion artifact reduction in fan-beam CT. IEEE Trans Med Imaging 25 (2006) 792-803
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 792-803
    • Yu, H.1    Wei, Y.2    Hsieh, J.3    Wang, G.4
  • 16
    • 0043237770 scopus 로고    scopus 로고
    • Image registration methods: a survey
    • Zitova B., and Flusser J. Image registration methods: a survey. Image Vision Comput 21 (2003) 977-1000
    • (2003) Image Vision Comput , vol.21 , pp. 977-1000
    • Zitova, B.1    Flusser, J.2
  • 17
    • 85057403488 scopus 로고    scopus 로고
    • Hajnal J.V., Hill D.L.G., and Hawkes D.J. (Eds), CRC Press, Boca Raton, FL
    • In: Hajnal J.V., Hill D.L.G., and Hawkes D.J. (Eds). Medical image registration (2001), CRC Press, Boca Raton, FL
    • (2001) Medical image registration
  • 18
    • 0344033872 scopus 로고    scopus 로고
    • The adaptive bases algorithm for intensity-based nonrigid image registration
    • Rohde G.K., Aldroubi A., and Dawant B.M. The adaptive bases algorithm for intensity-based nonrigid image registration. IEEE Trans Med Imaging 22 (2003) 1470-1479
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 1470-1479
    • Rohde, G.K.1    Aldroubi, A.2    Dawant, B.M.3
  • 19
    • 0041877344 scopus 로고    scopus 로고
    • A comparison of PDE-based non-linear anistropic diffusion techniques for image denoising
    • Weeratunga S.K., and Kamath C. A comparison of PDE-based non-linear anistropic diffusion techniques for image denoising. Proc SPIE 5014 (2003) 201-212
    • (2003) Proc SPIE , vol.5014 , pp. 201-212
    • Weeratunga, S.K.1    Kamath, C.2
  • 20
    • 0036055369 scopus 로고    scopus 로고
    • PDE-based non-linear diffusion techniques for denoising scientific and industrial images: an empirical study
    • Weeratunga S.K., and Kamath C. PDE-based non-linear diffusion techniques for denoising scientific and industrial images: an empirical study. Proc SPIE 4667 (2002) 279-290
    • (2002) Proc SPIE , vol.4667 , pp. 279-290
    • Weeratunga, S.K.1    Kamath, C.2
  • 21
    • 0025465145 scopus 로고
    • Scale-space and edge-detection using anisotropic diffusion
    • Perona P., and Malik J. Scale-space and edge-detection using anisotropic diffusion. IEEE Trans Pattern Anal Machine Intell 12 (1990) 629-639
    • (1990) IEEE Trans Pattern Anal Machine Intell , vol.12 , pp. 629-639
    • Perona, P.1    Malik, J.2
  • 22
    • 0026633317 scopus 로고
    • A simplified formulation of the gamma variate function
    • Madsen M.T. A simplified formulation of the gamma variate function. Phys Med Biol 37 (1992) 1597-1600
    • (1992) Phys Med Biol , vol.37 , pp. 1597-1600
    • Madsen, M.T.1
  • 23
    • 0021034659 scopus 로고
    • The derivation of the gamma-variate relationship for tracer dilution curves
    • Davenport R. The derivation of the gamma-variate relationship for tracer dilution curves. J Nucl Med 24 (1983) 945-948
    • (1983) J Nucl Med , vol.24 , pp. 945-948
    • Davenport, R.1
  • 24
    • 0038363381 scopus 로고    scopus 로고
    • CT-based assessment of regional pulmonary microvascular blood flow parameters
    • Won C., Chon D., Tajik J., et al. CT-based assessment of regional pulmonary microvascular blood flow parameters. J Appl Physiol 94 (2003) 2483-2493
    • (2003) J Appl Physiol , vol.94 , pp. 2483-2493
    • Won, C.1    Chon, D.2    Tajik, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.