메뉴 건너뛰기




Volumn 16, Issue 3, 2009, Pages 351-357

Interactive Deformation Registration of Endorectal Prostate MRI Using ITK Thin Plate Splines

Author keywords

deformable registration; Insight Segmentation and Registration Toolkit; Prostate cancer; radiotherapy; thin plate spline

Indexed keywords

ALGORITHM; ARTICLE; BLADDER; CANCER RADIOTHERAPY; COMPUTER PROGRAM; INSIGHT SEGMENTATION AND REGISTRATION TOOLKIT; MEDICAL INSTRUMENTATION; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT MONITORING; PELVIS; PHANTOM; PRIORITY JOURNAL; PROSTATE; PROSTATE CANCER; RECTUM; SEMINAL VESICLE; THIN PLATE SPLINE; TREATMENT PLANNING;

EID: 59449092567     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2008.09.011     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 23244432237 scopus 로고    scopus 로고
    • Magnetic resonance imaging anatomy of the prostate and periprostatic area: a guide for radiotherapists
    • Villeirs G.M., Verstraete K.L., De Neve W.J., and De Meerleer G.O. Magnetic resonance imaging anatomy of the prostate and periprostatic area: a guide for radiotherapists. Radiother Oncol 76 (2005) 99-106
    • (2005) Radiother Oncol , vol.76 , pp. 99-106
    • Villeirs, G.M.1    Verstraete, K.L.2    De Neve, W.J.3    De Meerleer, G.O.4
  • 2
    • 24944453139 scopus 로고    scopus 로고
    • Functional anatomy of the prostate: implications for treatment planning
    • McLaughlin P.W., Troyer S., Berri S., et al. Functional anatomy of the prostate: implications for treatment planning. Int J Radiat Oncol Biol Phys 63 (2005) 479-491
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 479-491
    • McLaughlin, P.W.1    Troyer, S.2    Berri, S.3
  • 4
    • 33645960986 scopus 로고    scopus 로고
    • IMRT boost dose planning on dominant intraprostatic lesions: gold marker-based three-dimensional fusion of CT with dynamic contrast-enhanced and 1H-spectroscopic MRI
    • van Lin E.N., Futterer J.J., Heijmink S.W., et al. IMRT boost dose planning on dominant intraprostatic lesions: gold marker-based three-dimensional fusion of CT with dynamic contrast-enhanced and 1H-spectroscopic MRI. Int J Radiat Oncol Biol Phys 65 (2006) 291-303
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 291-303
    • van Lin, E.N.1    Futterer, J.J.2    Heijmink, S.W.3
  • 5
    • 31844456046 scopus 로고    scopus 로고
    • Registration of MR prostate images with biomechanical modeling and nonlinear parameter estimation
    • Alterovitz R., Goldberg K., Pouliot J., et al. Registration of MR prostate images with biomechanical modeling and nonlinear parameter estimation. Med Phys 33 (2006) 446-454
    • (2006) Med Phys , vol.33 , pp. 446-454
    • Alterovitz, R.1    Goldberg, K.2    Pouliot, J.3
  • 6
    • 34547471527 scopus 로고    scopus 로고
    • Development of multiorgan finite element-based prostate deformation model enabling registration of endorectal coil magnetic resonance imaging for radiotherapy planning
    • Hensel J.M., Ménard C., Chung P.W., et al. Development of multiorgan finite element-based prostate deformation model enabling registration of endorectal coil magnetic resonance imaging for radiotherapy planning. Int J Radiat Oncol Biol Phys 68 (2007) 1522-1528
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 1522-1528
    • Hensel, J.M.1    Ménard, C.2    Chung, P.W.3
  • 7
    • 18944396614 scopus 로고    scopus 로고
    • Narrow band deformable registration of prostate magnetic resonance imaging, magnetic resonance spectroscopic imaging, and computed tomography studies
    • Schreibmann E., and Xing L. Narrow band deformable registration of prostate magnetic resonance imaging, magnetic resonance spectroscopic imaging, and computed tomography studies. Int J Radiat Oncol Biol Phys 62 (2005) 595-605
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 595-605
    • Schreibmann, E.1    Xing, L.2
  • 8
    • 34547800279 scopus 로고    scopus 로고
    • FEM-based evaluation of deformable image registration for radiation therapy
    • Zhong H., Peters T., and Siebers J.V. FEM-based evaluation of deformable image registration for radiation therapy. Phys Med Biol 52 (2007) 4721-4738
    • (2007) Phys Med Biol , vol.52 , pp. 4721-4738
    • Zhong, H.1    Peters, T.2    Siebers, J.V.3
  • 10
    • 34250830971 scopus 로고
    • Principal warps: thin-plate splines and the decomposition of deformations
    • Bookstein F.L. Principal warps: thin-plate splines and the decomposition of deformations. IEEE Trans Pattern Anal Mach Intell 11 (1989) 567-585
    • (1989) IEEE Trans Pattern Anal Mach Intell , vol.11 , pp. 567-585
    • Bookstein, F.L.1
  • 11
    • 9244236565 scopus 로고    scopus 로고
    • Mapping of the prostate in endorectal coil-based MRI/MRSI and CT: a deformable registration and validation study
    • Lian J., Xing L., Hunjan S., et al. Mapping of the prostate in endorectal coil-based MRI/MRSI and CT: a deformable registration and validation study. Med Phys 31 (2004) 3087-3094
    • (2004) Med Phys , vol.31 , pp. 3087-3094
    • Lian, J.1    Xing, L.2    Hunjan, S.3
  • 12
    • 22444448702 scopus 로고    scopus 로고
    • Semiautomatic nonrigid registration for the prostate and pelvic MR volumes
    • Fei B., Duerk J.L., Sodee D.B., and Wilson D.L. Semiautomatic nonrigid registration for the prostate and pelvic MR volumes. Acad Radiol 12 (2005) 815-824
    • (2005) Acad Radiol , vol.12 , pp. 815-824
    • Fei, B.1    Duerk, J.L.2    Sodee, D.B.3    Wilson, D.L.4
  • 13
    • 14544300120 scopus 로고    scopus 로고
    • Validation of contour-driven thin-plate splines for tracking fraction-to-fraction changes in anatomy and radiation therapy dose mapping
    • Schaly B., Bauman G.S., Battista J.J., and Van Dyk J. Validation of contour-driven thin-plate splines for tracking fraction-to-fraction changes in anatomy and radiation therapy dose mapping. Phys Med Biol 50 (2005) 459-475
    • (2005) Phys Med Biol , vol.50 , pp. 459-475
    • Schaly, B.1    Bauman, G.S.2    Battista, J.J.3    Van Dyk, J.4
  • 14
    • 27144504376 scopus 로고    scopus 로고
    • Integrating segmentation methods from the Insight Toolkit into a visualization application
    • Martin K., Ibáñez L., Avila L., Barré S., and Kaspersen J.H. Integrating segmentation methods from the Insight Toolkit into a visualization application. Med Image Anal 9 (2005) 579-593
    • (2005) Med Image Anal , vol.9 , pp. 579-593
    • Martin, K.1    Ibáñez, L.2    Avila, L.3    Barré, S.4    Kaspersen, J.H.5
  • 15
    • 13844294405 scopus 로고    scopus 로고
    • Implementation and validation of a three-dimensional deformable registration algorithm for targeted prostate cancer radiotherapy
    • Wang H., Dong L., Lii M.F., et al. Implementation and validation of a three-dimensional deformable registration algorithm for targeted prostate cancer radiotherapy. Int J Radiat Oncol Biol Phys 61 (2005) 725-735
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 725-735
    • Wang, H.1    Dong, L.2    Lii, M.F.3
  • 18
    • 84975553202 scopus 로고
    • Closed-form solution of absolute orientation using unit quaternions
    • Horn B.K.P. Closed-form solution of absolute orientation using unit quaternions. J Optical Soc Am 4 (1987) 629-642
    • (1987) J Optical Soc Am , vol.4 , pp. 629-642
    • Horn, B.K.P.1
  • 19
    • 14844286440 scopus 로고    scopus 로고
    • Dose-response characteristics of low- and intermediate-risk prostate cancer treated with external beam radiotherapy
    • Cheung R., Tucker S.L., Lee A.K., et al. Dose-response characteristics of low- and intermediate-risk prostate cancer treated with external beam radiotherapy. Int J Radiat Oncol Biol Phys 61 (2005) 993-1002
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 993-1002
    • Cheung, R.1    Tucker, S.L.2    Lee, A.K.3
  • 20
    • 0037489763 scopus 로고    scopus 로고
    • Dose-response for biochemical control among high-risk prostate cancer patients after external beam radiotherapy
    • Cheung R., Tucker S.L., Dong L., and Kuban D. Dose-response for biochemical control among high-risk prostate cancer patients after external beam radiotherapy. Int J Radiat Oncol Biol Phys 56 (2003) 1234-1240
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 1234-1240
    • Cheung, R.1    Tucker, S.L.2    Dong, L.3    Kuban, D.4
  • 21
    • 1842528895 scopus 로고    scopus 로고
    • Characterization of rectal normal tissue complication probability after high-dose external beam radiotherapy for prostate cancer
    • Cheung R., Tucker S.L., Ye J.S., et al. Characterization of rectal normal tissue complication probability after high-dose external beam radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 58 (2004) 1513-1519
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 1513-1519
    • Cheung, R.1    Tucker, S.L.2    Ye, J.S.3
  • 22
    • 33847283417 scopus 로고    scopus 로고
    • Identification of the bladder dose and volume factors to control late urinary toxicity after external beam radiotherapy for prostate cancer
    • Cheung R., Tucker S.L., Dong L., et al. Identification of the bladder dose and volume factors to control late urinary toxicity after external beam radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 67 (2007) 1059-1065
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1059-1065
    • Cheung, R.1    Tucker, S.L.2    Dong, L.3
  • 24
    • 33845949703 scopus 로고    scopus 로고
    • Using a priori structural information from magnetic resonance imaging to investigate the feasibility of prostate diffuse optical tomography and spectroscopy: a simulation study
    • Li C., Liengsawangwong R., Choi H., and Cheung R. Using a priori structural information from magnetic resonance imaging to investigate the feasibility of prostate diffuse optical tomography and spectroscopy: a simulation study. Med Phys 34 (2007) 266-274
    • (2007) Med Phys , vol.34 , pp. 266-274
    • Li, C.1    Liengsawangwong, R.2    Choi, H.3    Cheung, R.4
  • 25
    • 33744930583 scopus 로고    scopus 로고
    • User-guided active contour segmentation of anatomical structures: significantly improved efficiency and reliability
    • Yushkevich P.A., Piven J., Cody H., Ho S., Gee J.C., and Gerig G. User-guided active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31 (2006) 1116-1128
    • (2006) Neuroimage , vol.31 , pp. 1116-1128
    • Yushkevich, P.A.1    Piven, J.2    Cody, H.3    Ho, S.4    Gee, J.C.5    Gerig, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.