메뉴 건너뛰기




Volumn 33, Issue 2, 2006, Pages 446-454

Registration of MR prostate images with biomechanical modeling and nonlinear parameter estimation

Author keywords

Deformable image registration; Nonlinear image warping; Prostate finite element model; Prostate therapy; Registration

Indexed keywords

BALLOONS; BIOMECHANICS; COMPUTERIZED TOMOGRAPHY; DEFORMATION; DISEASES; FINITE ELEMENT METHOD; HISTOLOGY; IMAGE REGISTRATION; IMAGE SEGMENTATION; MAGNETIC RESONANCE SPECTROSCOPY; MAGNETISM; NONLINEAR PROGRAMMING; PARAMETER ESTIMATION; PROBES; RESONANCE; TISSUE; UNCERTAINTY ANALYSIS; UROLOGY;

EID: 31844456046     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2163391     Document Type: Article
Times cited : (80)

References (31)
  • 1
    • 85027231115 scopus 로고    scopus 로고
    • National Center for Health Statistics, "Prostate disease." Available at http://www.cdc.gov/nchs/fastats/prostate.htm
    • Prostate Disease
  • 2
    • 0029890838 scopus 로고    scopus 로고
    • Prostate cancer: Metabolic response to cryosurgery as detected with 3D H-1 MR spectroscopic imaging
    • J. Kurhanewicz, H. Hricak, D. B. Vigneron et al., "Prostate cancer: Metabolic response to cryosurgery as detected with 3D H-1 MR spectroscopic imaging," Radiology 200, 489-496 (1996).
    • (1996) Radiology , vol.200 , pp. 489-496
    • Kurhanewicz, J.1    Hricak, H.2    Vigneron, D.B.3
  • 4
    • 0034087595 scopus 로고    scopus 로고
    • Three-dimensional magnetic resonance spectroscopic imaging of brain and prostate cancer
    • J. Kurhanewicz, D. Vigneron, and S. J. Nelson, "Three-dimensional magnetic resonance spectroscopic imaging of brain and prostate cancer," Neoplasia 2, 166-189 (2000).
    • (2000) Neoplasia , vol.2 , pp. 166-189
    • Kurhanewicz, J.1    Vigneron, D.2    Nelson, S.J.3
  • 5
    • 0032757964 scopus 로고    scopus 로고
    • Prostate cancer: Localization with three-dimensional proton MR spectroscopic imaging - Clinicopathologic study
    • J. Scheidler, H. Hricak, D. B. Vigneron et al., "Prostate cancer: Localization with three-dimensional proton MR spectroscopic imaging - clinicopathologic study," Radiology 213, 473-480 (1999).
    • (1999) Radiology , vol.213 , pp. 473-480
    • Scheidler, J.1    Hricak, H.2    Vigneron, D.B.3
  • 6
    • 0036794336 scopus 로고    scopus 로고
    • Combined magnetic resonance imaging and spectroscopic imaging approach to molecular imaging of prostate cancer
    • J. Kurhanewicz, M. Swanson, S. J. Nelson, and D. Vigneron, "Combined magnetic resonance imaging and spectroscopic imaging approach to molecular imaging of prostate cancer," J. Magn. Reson Imaging 16, 451-463 (2002).
    • (2002) J. Magn. Reson Imaging , vol.16 , pp. 451-463
    • Kurhanewicz, J.1    Swanson, M.2    Nelson, S.J.3    Vigneron, D.4
  • 7
    • 3042658240 scopus 로고    scopus 로고
    • Inverse planning for HDR prostate brachytherapy use to boost dominant intra-prostatic lesion defined by magnetic-resonance spectroscopy imaging
    • J. Pouliot, Y. Kim, E. Lessard, I. C. Hsu, D. Vigneron, and J. Kurhanewicz, "Inverse planning for HDR prostate brachytherapy use to boost dominant intra-prostatic lesion defined by magnetic-resonance spectroscopy imaging," Int. J. Radiat. Oncol., Biol., Phys. 59, 1196-1207 (2004).
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.59 , pp. 1196-1207
    • Pouliot, J.1    Kim, Y.2    Lessard, E.3    Hsu, I.C.4    Vigneron, D.5    Kurhanewicz, J.6
  • 8
    • 0035010591 scopus 로고    scopus 로고
    • Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function
    • E. Lessard and J. Pouliot, "Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function," Med. Phys. 28, 773-779 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 773-779
    • Lessard, E.1    Pouliot, J.2
  • 9
    • 0032980110 scopus 로고    scopus 로고
    • Static field intensity modulation to treat a dominant intraprostatic lesion to 90 Gy compared to seven field 3-dimensional radiotherapy
    • B. Pickett, E. Vigneault, J. Kurhanewicz, L. Verhey, and M. Roach, "Static field intensity modulation to treat a dominant intraprostatic lesion to 90 Gy compared to seven field 3-dimensional radiotherapy," Int. J. Radiat. Oncol., Biol., Phys. 43, 921-929 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.43 , pp. 921-929
    • Pickett, B.1    Vigneault, E.2    Kurhanewicz, J.3    Verhey, L.4    Roach, M.5
  • 10
    • 0035450631 scopus 로고    scopus 로고
    • Forward or inversely planned segmental multileaf collimator IMRT and sequential tomotherapy to treat multiple dominant intraprostatic lesions of prostate cancer to 90 Gy
    • P. Xia, B. Pickett, E. Vigneault, L. Verhey, and M. Roach, "Forward or inversely planned segmental multileaf collimator IMRT and sequential tomotherapy to treat multiple dominant intraprostatic lesions of prostate cancer to 90 Gy," Int. J. Radiat. Oncol., Biol., Phys. 51, 244-254 (2001).
    • (2001) Int. J. Radiat. Oncol., Biol., Phys. , vol.51 , pp. 244-254
    • Xia, P.1    Pickett, B.2    Vigneault, E.3    Verhey, L.4    Roach, M.5
  • 11
    • 17144455949 scopus 로고    scopus 로고
    • Treatment planning for prostate implants using magnetic-resonance spectroscopy imaging
    • M. Zaider, M. J. Zelefsky, E. K. Lee et al., "Treatment planning for prostate implants using magnetic-resonance spectroscopy imaging," Int. J. Radiat. Oncol., Biol., Phys. 47, 1085-1096 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.47 , pp. 1085-1096
    • Zaider, M.1    Zelefsky, M.J.2    Lee, E.K.3
  • 12
    • 0028113557 scopus 로고
    • Carcinoma of the prostate gland: MR imaging with pelvic phased-array coils versus integrated endorectal - Pelvic phased-array coils
    • H. Hricak, S. White, D. Vigneron, J. Kurhanewicz, A. Kosco, D. Levin, J. Weiss, P. Narayan, and P. R. Carroll, "Carcinoma of the prostate gland: MR imaging with pelvic phased-array coils versus integrated endorectal - pelvic phased-array coils," Radiology 193, 703-709 (1994).
    • (1994) Radiology , vol.193 , pp. 703-709
    • Hricak, H.1    White, S.2    Vigneron, D.3    Kurhanewicz, J.4    Kosco, A.5    Levin, D.6    Weiss, J.7    Narayan, P.8    Carroll, P.R.9
  • 13
    • 0026858273 scopus 로고
    • Pelvic imaging with phased array coils: Quantitative assessment of signal-to-noise ratio improvement
    • C. E. Hayes, M. J. Dietz, B. F. King, and R. L. Ehman, "Pelvic imaging with phased array coils: quantitative assessment of signal-to-noise ratio improvement," J. Magn. Reson. (1969-1992) 2, 321-326 (1992).
    • (1992) J. Magn. Reson. (1969-1992) , vol.2 , pp. 321-326
    • Hayes, C.E.1    Dietz, M.J.2    King, B.F.3    Ehman, R.L.4
  • 14
    • 0031693144 scopus 로고    scopus 로고
    • Magnetic resonance imaging of prostate cancer: Comparison of image quality using endorectal and pelvic phased array coils
    • J. E. Husband, A. R. Padhani, A. D. MacVicar, and P. Revell, "Magnetic resonance imaging of prostate cancer: comparison of image quality using endorectal and pelvic phased array coils," Clin. Radiol. 53, 673-681 (1998).
    • (1998) Clin. Radiol. , vol.53 , pp. 673-681
    • Husband, J.E.1    Padhani, A.R.2    MacVicar, A.D.3    Revell, P.4
  • 15
    • 31844453906 scopus 로고    scopus 로고
    • Expandable and rigid endorectal coils for prostate MRI: Impact on prostate distortion and rigid image registration
    • Y. Kim, I. C. Hsu, J. Pouliot, S. M. Noworolski, D. B. Vigneron, and J. Kurhanewicz, "Expandable and rigid endorectal coils for prostate MRI: Impact on prostate distortion and rigid image registration," Med. Phys. 32, 3569-3578 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 3569-3578
    • Kim, Y.1    Hsu, I.C.2    Pouliot, J.3    Noworolski, S.M.4    Vigneron, D.B.5    Kurhanewicz, J.6
  • 17
    • 0037034599 scopus 로고    scopus 로고
    • Automatic MR volume registration and its evaluation for the pelvis and prostate
    • B. Fei, A. Wheaton, Z. Lee, J. I. Duerk, and D. Wilson, "Automatic MR volume registration and its evaluation for the pelvis and prostate," Phys. Med. Biol. 47, 823-838 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 823-838
    • Fei, B.1    Wheaton, A.2    Lee, Z.3    Duerk, J.I.4    Wilson, D.5
  • 18
    • 0037410891 scopus 로고    scopus 로고
    • A comparative study of warping and rigid body registration for the prostate and pelvic MR volumes
    • B. Fei, C. Kemper, and D. L. Wilson, "A comparative study of warping and rigid body registration for the prostate and pelvic MR volumes," Comput. Med. Imaging Graph. 27, 267-281 (2003).
    • (2003) Comput. Med. Imaging Graph. , vol.27 , pp. 267-281
    • Fei, B.1    Kemper, C.2    Wilson, D.L.3
  • 19
    • 23944480754 scopus 로고    scopus 로고
    • Deformable image registration using multiresolution B-splines
    • abstract
    • M. Kessler, M. Roberson, R. Zeng, and J. Fessler, "Deformable image registration using multiresolution B-splines," Med. Phys. 31, 1792 (2004) (abstract).
    • (2004) Med. Phys. , vol.31 , pp. 1792
    • Kessler, M.1    Roberson, M.2    Zeng, R.3    Fessler, J.4
  • 20
    • 1842476743 scopus 로고    scopus 로고
    • Deformable image registration for the use of Magnetic Resonance Spectroscopy in prostate treatment planning
    • X. Wu, S. J. Dibiase, R. Gullapalli, and C. X. Yu, "Deformable image registration for the use of Magnetic Resonance Spectroscopy in prostate treatment planning," Int. J. Radiat. Oncol., Biol., Phys. 58, 1577-1583 (2004).
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.58 , pp. 1577-1583
    • Wu, X.1    Dibiase, S.J.2    Gullapalli, R.3    Yu, C.X.4
  • 21
  • 23
    • 0344823849 scopus 로고    scopus 로고
    • Medially based meshing with finite element analysis of prostate deformation
    • Medical Image Computing and Computer-Assisted Intervention, Montreal, Canada
    • J. R. Crouch, S. M. Pizer, E. L. Chaney, and M. Zaider, "Medially based meshing with finite element analysis of prostate deformation" Medical Image Computing and Computer-Assisted Intervention, MICCAI 2003-6th International Conference Proceedings, Montreal, Canada, 2003, pp. 108-115.
    • (2003) MICCAI 2003-6th International Conference Proceedings , pp. 108-115
    • Crouch, J.R.1    Pizer, S.M.2    Chaney, E.L.3    Zaider, M.4
  • 25
    • 85027233159 scopus 로고    scopus 로고
    • Chap 6. PROSE Pulse Sequence, 2333956-100 Rev. 0 (05/02), General Electric Company
    • "Signa® LX Release 9.1," Chap 6. PROSE Pulse Sequence, 2333956-100 Rev. 0 (05/02), General Electric Company, 2002.
    • (2002) Signa® LX Release 9.1
  • 26
    • 0000250265 scopus 로고
    • Measures of the amount of ecologic association between species
    • L. R. Dice, "Measures of the amount of ecologic association between species," Ecology 26, 297-302 (1945).
    • (1945) Ecology , vol.26 , pp. 297-302
    • Dice, L.R.1
  • 27
    • 84975553202 scopus 로고
    • Closed-form solution of absolute orientation using unit quaternions
    • R. Horn, "Closed-form solution of absolute orientation using unit quaternions," J. Opt. Soc. Am. A 4, 629-642 (1987).
    • (1987) J. Opt. Soc. Am. A , vol.4 , pp. 629-642
    • Horn, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.