Volumn 36, Issue 2, 2009, Pages 317-328

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

Author keywords

erenkov; IMRT; Plastic scintillator dosimetry

Indexed keywords

CALIBRATION; DOSIMETERS; DOSIMETRY; IRRADIATION; PHOTOIONIZATION; PHOTONS; POLYSTYRENES; SCINTILLATION COUNTERS; TISSUE;

EID: 59249091676     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3013703     Document Type: Article
Times cited : (28)

References (19)
  • 2
    • 10744231470 scopus 로고    scopus 로고
    • Guidance document on delivery, treatment planning and clinical implementation of IMRT
    • Report of the IMRT subcommittee of the AAPM radiation therapy committee.
    • G. A. Ezzell, J. M. Galvin, D. Low, J. R. Palta, I. Rosen, M. B. Sharpe, P. Xiao, L. Xing, and C. X. Yu, " Guidance document on delivery, treatment planning and clinical implementation of IMRT.," Report of the IMRT subcommittee of the AAPM radiation therapy committee, Med. Phys. 30, 2089-2115 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2089-2115
    • Ezzell, G.A.1    Galvin, J.M.2    Low, D.3    Palta, J.R.4    Rosen, I.5    Sharpe, M.B.6    Xiao, P.7    Xing, L.8    Yu, C.X.9
  • 3
    • 33947408376 scopus 로고    scopus 로고
    • Dosimetry in modern radiation therapy: Limitations and need
    • L. J. Schreiner, " Dosimetry in modern radiation therapy: Limitations and need.," Med. Phys. 56, 1-13 (2006).
    • (2006) Med. Phys. , vol.56 , pp. 1-13
    • Schreiner, L.J.1
  • 4
    • 33947400267 scopus 로고    scopus 로고
    • Review of recent advances in non gel dosimetry
    • K. Jordan, " Review of recent advances in non gel dosimetry.," J. Phys.: Conf. Ser. 56, 132-141 (2006).
    • (2006) J. Phys.: Conf. Ser. , vol.56 , pp. 132-141
    • Jordan, K.1
  • 5
    • 0036703563 scopus 로고    scopus 로고
    • Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by static multileaf collimator
    • X. R. Zhu, P. A. Jursinic, D. F. Grimm, F. Lopez, J. J. Rownd, and M. T. Gillin, " Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by static multileaf collimator.," Med. Phys. 29, 1687-1692 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1687-1692
    • Zhu, X.R.1    Jursinic, P.A.2    Grimm, D.F.3    Lopez, F.4    Rownd, J.J.5    Gillin, M.T.6
  • 7
    • 33947400268 scopus 로고    scopus 로고
    • 3D dosimetry by optical CT scanning
    • M. Oldham, " 3D dosimetry by optical CT scanning.," J. Phys. Conf. Ser. 56, 58-71 (2006).
    • (2006) J. Phys. Conf. Ser. , vol.56 , pp. 58-71
    • Oldham, M.1
  • 9
    • 1542603236 scopus 로고    scopus 로고
    • Evaluation of a 2D diode array for IMRT quality assurance
    • D. Letourneau, M. Gulam, D. Yan, M. Oldham, and J. W. Wong, " Evaluation of a 2D diode array for IMRT quality assurance.," Radiother. Oncol. 70 (2), 199-206 (2004).
    • (2004) Radiother. Oncol. , vol.70 , Issue.2 , pp. 199-206
    • Letourneau, D.1    Gulam, M.2    Yan, D.3    Oldham, M.4    Wong, J.W.5
  • 11
    • 0026804696 scopus 로고
    • Water equivalent plastic scintillators detectors for high energy beam dosimetry: I Physical characteristics and technical considerations
    • A. S. Beddar, T. R. Mackie, and F. H. Mattix, " Water equivalent plastic scintillators detectors for high energy beam dosimetry: I Physical characteristics and technical considerations.," Phys. Med. Biol. 37, 1883-1900 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    MacKie, T.R.2    Mattix, F.H.3
  • 12
    • 56349120663 scopus 로고    scopus 로고
    • Plastic scintillator dosimetry: Optimal selection of scintillating fibers and scintillators
    • L. Archambauld, J. Arsenau, L. Gringas, A. S. Beddar, R. Roy, and L. Beaulieu, " Plastic scintillator dosimetry: Optimal selection of scintillating fibers and scintillators.," Med. Phys. 32, 3750-3754 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 3750-3754
    • Archambauld, L.1    Arsenau, J.2    Gringas, L.3    Beddar, A.S.4    Roy, R.5    Beaulieu, L.6
  • 14
    • 31044441058 scopus 로고    scopus 로고
    • Development and characterization of a tissue equivalent scintillator based dosimetry system
    • M. P. Petric, J. L. Robar, and B. Clark, " Development and characterization of a tissue equivalent scintillator based dosimetry system.," Med. Phys. 33, 96-105 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 96-105
    • Petric, M.P.1    Robar, J.L.2    Clark, B.3
  • 15
    • 85092678986 scopus 로고    scopus 로고
    • The DOSIMAP, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cenrekov discrimination methods
    • (to be published).
    • A. M. Frelin, J. M. Fontbonne, G. Ban, J. Colin, M. Labalme, A. Batalla, A. Vela, P. Boher, M. Braud, and T. Leroux, " The DOSIMAP, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cenrekov discrimination methods.," Med. Phys. (to be published).
    • Med. Phys.
    • Frelin, A.M.1    Fontbonne, J.M.2    Ban, G.3    Colin, J.4    Labalme, M.5    Batalla, A.6    Vela, A.7    Boher, P.8    Braud, M.9    Leroux, T.10
  • 18
    • 0003682469 scopus 로고
    • ICRU Report 44, International Commission on Radiation Units and Measurements.
    • " Tissue substitutes in radiation dosimetry and measurement.," ICRU Report 44, International Commission on Radiation Units and Measurements, 1989.
    • (1989) Tissue Substitutes in Radiation Dosimetry and Measurement


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.