2
-
-
10744231470
-
Guidance document on delivery, treatment planning and clinical implementation of IMRT
-
Report of the IMRT subcommittee of the AAPM radiation therapy committee.
-
G. A. Ezzell, J. M. Galvin, D. Low, J. R. Palta, I. Rosen, M. B. Sharpe, P. Xiao, L. Xing, and C. X. Yu, " Guidance document on delivery, treatment planning and clinical implementation of IMRT.," Report of the IMRT subcommittee of the AAPM radiation therapy committee, Med. Phys. 30, 2089-2115 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 2089-2115
-
-
Ezzell, G.A.1
Galvin, J.M.2
Low, D.3
Palta, J.R.4
Rosen, I.5
Sharpe, M.B.6
Xiao, P.7
Xing, L.8
Yu, C.X.9
-
3
-
-
33947408376
-
Dosimetry in modern radiation therapy: Limitations and need
-
L. J. Schreiner, " Dosimetry in modern radiation therapy: Limitations and need.," Med. Phys. 56, 1-13 (2006).
-
(2006)
Med. Phys.
, vol.56
, pp. 1-13
-
-
Schreiner, L.J.1
-
4
-
-
33947400267
-
Review of recent advances in non gel dosimetry
-
K. Jordan, " Review of recent advances in non gel dosimetry.," J. Phys.: Conf. Ser. 56, 132-141 (2006).
-
(2006)
J. Phys.: Conf. Ser.
, vol.56
, pp. 132-141
-
-
Jordan, K.1
-
5
-
-
0036703563
-
Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by static multileaf collimator
-
X. R. Zhu, P. A. Jursinic, D. F. Grimm, F. Lopez, J. J. Rownd, and M. T. Gillin, " Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by static multileaf collimator.," Med. Phys. 29, 1687-1692 (2002).
-
(2002)
Med. Phys.
, vol.29
, pp. 1687-1692
-
-
Zhu, X.R.1
Jursinic, P.A.2
Grimm, D.F.3
Lopez, F.4
Rownd, J.J.5
Gillin, M.T.6
-
6
-
-
27144483940
-
-
Master's thesis, University of Oldenburg, Germany.
-
A. Djouguela, " Film dosimetry physical aspects, working conditions and application in modern radiotherapy.," Master's thesis, University of Oldenburg, Germany, 2005.
-
(2005)
Film Dosimetry Physical Aspects, Working Conditions and Application in Modern Radiotherapy
-
-
Djouguela, A.1
-
7
-
-
33947400268
-
3D dosimetry by optical CT scanning
-
M. Oldham, " 3D dosimetry by optical CT scanning.," J. Phys. Conf. Ser. 56, 58-71 (2006).
-
(2006)
J. Phys. Conf. Ser.
, vol.56
, pp. 58-71
-
-
Oldham, M.1
-
9
-
-
1542603236
-
Evaluation of a 2D diode array for IMRT quality assurance
-
D. Letourneau, M. Gulam, D. Yan, M. Oldham, and J. W. Wong, " Evaluation of a 2D diode array for IMRT quality assurance.," Radiother. Oncol. 70 (2), 199-206 (2004).
-
(2004)
Radiother. Oncol.
, vol.70
, Issue.2
, pp. 199-206
-
-
Letourneau, D.1
Gulam, M.2
Yan, D.3
Oldham, M.4
Wong, J.W.5
-
10
-
-
33645511871
-
Two dimensional ionization chamber arrays for IMRT plan verification
-
B. Poppe, A. Blechschmidt, A. Djougulea, R. Kollhoff, A. Rubach, K. C. Willborn, and D. Harder, " Two dimensional ionization chamber arrays for IMRT plan verification.," Med. Phys. 34 (4), 1005-1015 (2006).
-
(2006)
Med. Phys.
, vol.34
, Issue.4
, pp. 1005-1015
-
-
Poppe, B.1
Blechschmidt, A.2
Djougulea, A.3
Kollhoff, R.4
Rubach, A.5
Willborn, K.C.6
Harder, D.7
-
11
-
-
0026804696
-
Water equivalent plastic scintillators detectors for high energy beam dosimetry: I Physical characteristics and technical considerations
-
A. S. Beddar, T. R. Mackie, and F. H. Mattix, " Water equivalent plastic scintillators detectors for high energy beam dosimetry: I Physical characteristics and technical considerations.," Phys. Med. Biol. 37, 1883-1900 (1992).
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1883-1900
-
-
Beddar, A.S.1
MacKie, T.R.2
Mattix, F.H.3
-
12
-
-
56349120663
-
Plastic scintillator dosimetry: Optimal selection of scintillating fibers and scintillators
-
L. Archambauld, J. Arsenau, L. Gringas, A. S. Beddar, R. Roy, and L. Beaulieu, " Plastic scintillator dosimetry: Optimal selection of scintillating fibers and scintillators.," Med. Phys. 32, 3750-3754 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 3750-3754
-
-
Archambauld, L.1
Arsenau, J.2
Gringas, L.3
Beddar, A.S.4
Roy, R.5
Beaulieu, L.6
-
13
-
-
25644453647
-
Spectral discrimination of Cerenkov radiation in scintillating dosimeters
-
A. M. Frelin, J. M. Fontbonne, G. Ban, J. Colin, M. Labalme, A. Batalla, A. Isambert, A. Vela, and T. Leroux " Spectral discrimination of Cerenkov radiation in scintillating dosimeters.," Med. Phys. 32, 3000-3006 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 3000-3006
-
-
Frelin, A.M.1
Fontbonne, J.M.2
Ban, G.3
Colin, J.4
Labalme, M.5
Batalla, A.6
Isambert, A.7
Vela, A.8
Leroux, T.9
-
14
-
-
31044441058
-
Development and characterization of a tissue equivalent scintillator based dosimetry system
-
M. P. Petric, J. L. Robar, and B. Clark, " Development and characterization of a tissue equivalent scintillator based dosimetry system.," Med. Phys. 33, 96-105 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 96-105
-
-
Petric, M.P.1
Robar, J.L.2
Clark, B.3
-
15
-
-
85092678986
-
The DOSIMAP, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cenrekov discrimination methods
-
(to be published).
-
A. M. Frelin, J. M. Fontbonne, G. Ban, J. Colin, M. Labalme, A. Batalla, A. Vela, P. Boher, M. Braud, and T. Leroux, " The DOSIMAP, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cenrekov discrimination methods.," Med. Phys. (to be published).
-
Med. Phys.
-
-
Frelin, A.M.1
Fontbonne, J.M.2
Ban, G.3
Colin, J.4
Labalme, M.5
Batalla, A.6
Vela, A.7
Boher, P.8
Braud, M.9
Leroux, T.10
-
18
-
-
0003682469
-
-
ICRU Report 44, International Commission on Radiation Units and Measurements.
-
" Tissue substitutes in radiation dosimetry and measurement.," ICRU Report 44, International Commission on Radiation Units and Measurements, 1989.
-
(1989)
Tissue Substitutes in Radiation Dosimetry and Measurement
-
-
|