메뉴 건너뛰기




Volumn 47, Issue 1, 2009, Pages 1-11

CT Technology Overview: 64-Slice and Beyond

Author keywords

CT; CT technology; Dual source CT; Dynamic volume CT; Radiation dose; Reconstruction techniques

Indexed keywords

ANATOMY; BREATH HOLDING; CLINICAL PRACTICE; COMPARATIVE STUDY; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; DIAGNOSTIC IMAGING; HUMAN; PRIORITY JOURNAL; RADIATION DOSE; REVIEW; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; THICKNESS; X RAY;

EID: 58949084951     PISSN: 00338389     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rcl.2008.10.004     Document Type: Review
Times cited : (67)

References (23)
  • 1
  • 3
    • 0007047397 scopus 로고
    • Computerized transverse axial scanning (tomography): part I. Description of system 1973
    • Hounsfield G.N. Computerized transverse axial scanning (tomography): part I. Description of system 1973. Br J Radiol 68 (1995) H166-H172
    • (1995) Br J Radiol , vol.68
    • Hounsfield, G.N.1
  • 4
    • 0024362562 scopus 로고
    • Ultrafast cardiac CT scanning
    • Rumberger J.A., and Lipton M.J. Ultrafast cardiac CT scanning. Cardiol Clin 7 (1989) 713-734
    • (1989) Cardiol Clin , vol.7 , pp. 713-734
    • Rumberger, J.A.1    Lipton, M.J.2
  • 5
    • 39849108754 scopus 로고    scopus 로고
    • Evaluation of left and right ventricular diastolic function by electron-beam computed tomography in patients with passive epicardial constraint
    • Kloeters C., Dushe S., Dohmen P.M., et al. Evaluation of left and right ventricular diastolic function by electron-beam computed tomography in patients with passive epicardial constraint. J Comput Assist Tomogr 32 (2008) 78-85
    • (2008) J Comput Assist Tomogr , vol.32 , pp. 78-85
    • Kloeters, C.1    Dushe, S.2    Dohmen, P.M.3
  • 6
    • 40049111388 scopus 로고    scopus 로고
    • Antialiasing backprojection for helical MDCT
    • Mori I. Antialiasing backprojection for helical MDCT. Med Phys 35 (2008) 1065-1077
    • (2008) Med Phys , vol.35 , pp. 1065-1077
    • Mori, I.1
  • 7
    • 33744946817 scopus 로고    scopus 로고
    • Impact of the z-flying focal spot on resolution and artifact behavior for a 64-slice spiral CT scanner
    • Kyriakou Y., Kachelriess M., Knaup M., et al. Impact of the z-flying focal spot on resolution and artifact behavior for a 64-slice spiral CT scanner. Eur Radiol 16 (2006) 1206-1215
    • (2006) Eur Radiol , vol.16 , pp. 1206-1215
    • Kyriakou, Y.1    Kachelriess, M.2    Knaup, M.3
  • 8
    • 0022528370 scopus 로고
    • Tissue analysis by dual-energy computed tomography
    • Hawkes D.J., Jackson D.F., and Parker R.P. Tissue analysis by dual-energy computed tomography. Br J Radiol 59 (1986) 537-542
    • (1986) Br J Radiol , vol.59 , pp. 537-542
    • Hawkes, D.J.1    Jackson, D.F.2    Parker, R.P.3
  • 9
    • 0034977516 scopus 로고    scopus 로고
    • Advanced single-slice rebinning for tilted spiral cone-beam CT
    • Kachelriess M., Fuchs T., Schaller S., et al. Advanced single-slice rebinning for tilted spiral cone-beam CT. Med Phys 28 (2001) 1033-1041
    • (2001) Med Phys , vol.28 , pp. 1033-1041
    • Kachelriess, M.1    Fuchs, T.2    Schaller, S.3
  • 10
    • 0033999358 scopus 로고    scopus 로고
    • Advanced single-slice rebinning in cone-beam spiral CT
    • Kachelriess M., Schaller S., and Kalender W.A. Advanced single-slice rebinning in cone-beam spiral CT. Med Phys 27 (2000) 754-772
    • (2000) Med Phys , vol.27 , pp. 754-772
    • Kachelriess, M.1    Schaller, S.2    Kalender, W.A.3
  • 11
    • 0041961848 scopus 로고    scopus 로고
    • A generalized helical reconstruction algorithm for multidetector row CT
    • [abstract]
    • Hsieh J., Toth T.L., Simoni P., et al. A generalized helical reconstruction algorithm for multidetector row CT. Radiology 221 P (2001) 217 [abstract]
    • (2001) Radiology , vol.221 , Issue.PART , pp. 217
    • Hsieh, J.1    Toth, T.L.2    Simoni, P.3
  • 12
    • 0031956821 scopus 로고    scopus 로고
    • Algorithm for image reconstruction in multi-slice helical CT
    • Taguchi K., and Aradate H. Algorithm for image reconstruction in multi-slice helical CT. Med Phys 25 (1998) 550-561
    • (1998) Med Phys , vol.25 , pp. 550-561
    • Taguchi, K.1    Aradate, H.2
  • 13
    • 58949102486 scopus 로고    scopus 로고
    • Principle and performance of a dynamic collimation technique for spiral CT
    • SSA16-04
    • Flohr T., Stierstorfer K., Wolf H., et al. Principle and performance of a dynamic collimation technique for spiral CT. Radiology Society of North America (2007) SSA16-04
    • (2007) Radiology Society of North America
    • Flohr, T.1    Stierstorfer, K.2    Wolf, H.3
  • 14
    • 32844473798 scopus 로고    scopus 로고
    • Acute myocardial ischemia after aortic valve replacement: a comprehensive diagnostic evaluation using dynamic multislice spiral computed tomography
    • Lembcke A., Hein P.A., Enzweiler C.N., et al. Acute myocardial ischemia after aortic valve replacement: a comprehensive diagnostic evaluation using dynamic multislice spiral computed tomography. Eur J Radiol 57 (2006) 351-355
    • (2006) Eur J Radiol , vol.57 , pp. 351-355
    • Lembcke, A.1    Hein, P.A.2    Enzweiler, C.N.3
  • 15
    • 33750547401 scopus 로고    scopus 로고
    • Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography
    • Hsieh J., Londt J., Vass M., et al. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys 33 (2006) 4236-4248
    • (2006) Med Phys , vol.33 , pp. 4236-4248
    • Hsieh, J.1    Londt, J.2    Vass, M.3
  • 16
    • 0141560306 scopus 로고    scopus 로고
    • Spatial and temporal resolution with 16-slice computed tomography for cardiac imaging
    • Blobel J., Baartman H., Rogalla P., et al. Spatial and temporal resolution with 16-slice computed tomography for cardiac imaging. RöFo 175 (2003) 1264-1271
    • (2003) RöFo , vol.175 , pp. 1264-1271
    • Blobel, J.1    Baartman, H.2    Rogalla, P.3
  • 17
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr T.G., McCollough C.H., Bruder H., et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16 (2006) 256-268
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 18
    • 40349094459 scopus 로고    scopus 로고
    • New applications for noninvasive cardiac imaging: dual-source computed tomography
    • Rist C., Johnson T.R., Becker C.R., et al. New applications for noninvasive cardiac imaging: dual-source computed tomography. Eur Radiol 17 Suppl 6 (2007) F16-F25
    • (2007) Eur Radiol , vol.17 , Issue.SUPPL. 6
    • Rist, C.1    Johnson, T.R.2    Becker, C.R.3
  • 19
    • 36248997114 scopus 로고    scopus 로고
    • Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease
    • Scheffel H., Stolzmann P., Frauenfelder T., et al. Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease. Invest Radiol 42 (2007) 823-829
    • (2007) Invest Radiol , vol.42 , pp. 823-829
    • Scheffel, H.1    Stolzmann, P.2    Frauenfelder, T.3
  • 20
    • 36349008732 scopus 로고    scopus 로고
    • Intensity distribution and impact of scatter for dual-source CT
    • Kyriakou Y., and Kalender W.A. Intensity distribution and impact of scatter for dual-source CT. Phys Med Biol 52 (2007) 6969-6989
    • (2007) Phys Med Biol , vol.52 , pp. 6969-6989
    • Kyriakou, Y.1    Kalender, W.A.2
  • 21
    • 33746847768 scopus 로고    scopus 로고
    • A combination-weighted Feldkamp-based reconstruction algorithm for cone-beam CT
    • Mori S., Endo M., Komatsu S., et al. A combination-weighted Feldkamp-based reconstruction algorithm for cone-beam CT. Phys Med Biol 51 (2006) 3953-3965
    • (2006) Phys Med Biol , vol.51 , pp. 3953-3965
    • Mori, S.1    Endo, M.2    Komatsu, S.3
  • 22
    • 22844439460 scopus 로고    scopus 로고
    • Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector
    • Leng S., Zhuang T., Nett B.E., et al. Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector. Phys Med Biol 50 (2005) 1805-1820
    • (2005) Phys Med Biol , vol.50 , pp. 1805-1820
    • Leng, S.1    Zhuang, T.2    Nett, B.E.3
  • 23
    • 43449126798 scopus 로고    scopus 로고
    • Initial evaluation of coronary images from 320-detector row computed tomography
    • Rybicki F.J., Otero H.J., Steigner M.L., et al. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging 24 (2008) 535-546
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 535-546
    • Rybicki, F.J.1    Otero, H.J.2    Steigner, M.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.