메뉴 건너뛰기




Volumn 50, Issue 8, 2005, Pages 1805-1820

Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; DATA ACQUISITION; FILTRATION; MONTE CARLO METHODS; PROBLEM SOLVING;

EID: 22844439460     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/50/8/012     Document Type: Article
Times cited : (38)

References (22)
  • 2
    • 0038715540 scopus 로고    scopus 로고
    • A new framework of image reconstruction from fan beam projections
    • Chen G-H 2003 A new framework of image reconstruction from fan beam projections Med. Phys. 30 1151-61
    • (2003) Med. Phys. , vol.30 , pp. 1151-1161
    • Chen, G.-H.1
  • 3
    • 4043092769 scopus 로고    scopus 로고
    • A large class of inversion formulae for the 2D Radon transform of functions of compact support
    • Clackdoyle R and Noo F 2004 A large class of inversion formulae for the 2D Radon transform of functions of compact support Inverse Problems 20 1281-91
    • (2004) Inverse Problems , vol.20 , pp. 1281-1291
    • Clackdoyle, R.1    Noo, F.2
  • 4
    • 4043157202 scopus 로고    scopus 로고
    • A quantitative reconstruction from truncated projections in classical tomography
    • Clackdoyle R, Noo F, Guo J and Roberts J 2004 A quantitative reconstruction from truncated projections in classical tomography IEEE Trans. Nucl. Sci. 51 2570-8
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 2570-2578
    • Clackdoyle, R.1    Noo, F.2    Guo, J.3    Roberts, J.4
  • 5
    • 0036852526 scopus 로고    scopus 로고
    • Sinogram merging to compensate for truncation of projection data in tomotherapy imaing
    • Hooper H R and Fallone B G 2002 Sinogram merging to compensate for truncation of projection data in tomotherapy imaing Med. Phys. 29 2548-51
    • (2002) Med. Phys. , vol.29 , pp. 2548-2551
    • Hooper, H.R.1    Fallone, B.G.2
  • 8
    • 0036665224 scopus 로고    scopus 로고
    • Theoretically exact filtered backprojection-type inversion algorithms for spiral CT
    • Katsevich A 2002a Theoretically exact filtered backprojection-type inversion algorithms for spiral CT SIAM J. Appl. Math. 62 2012-26
    • (2002) SIAM J. Appl. Math. , vol.62 , pp. 2012-2026
    • Katsevich, A.1
  • 9
    • 0037036595 scopus 로고    scopus 로고
    • Analysis of an exact inversion algorithm for spiral cone-beam CT
    • Katsevich A 2002b Analysis of an exact inversion algorithm for spiral cone-beam CT Phys. Med. Biol. 47 2583-97
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2583-2597
    • Katsevich, A.1
  • 10
    • 2442661205 scopus 로고    scopus 로고
    • An improved exact filtered backprojection algorithm for spiral computed tomography
    • Katsevich A 2004 An improved exact filtered backprojection algorithm for spiral computed tomography Adv. Appl. Math. J. Math. Math. Sci. 32 681-97
    • (2004) Adv. Appl. Math. J. Math. Math. Sci. , vol.32 , pp. 681-697
    • Katsevich, A.1
  • 12
    • 0035428652 scopus 로고    scopus 로고
    • Transmission image reconstruction and redundant information in SPECT with asymmetric fanbeam collimation
    • La Riviere P J, Pan X, Gilland D, Kao C-M, Chang W and Jaszczak R 2001 Transmission image reconstruction and redundant information in SPECT with asymmetric fanbeam collimation IEEE Trans. Nucl. Sci. 48 1357-63
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 1357-1363
    • La Riviere, P.J.1    Pan, X.2    Gilland, D.3    Kao, C.-M.4    Chang, W.5    Jaszczak, R.6
  • 13
    • 0029516318 scopus 로고
    • A processing technique for the truncated projections of asymmetric-fan-beam transmission imaging
    • Loncaric S, Chang W and Huang G 1995 A processing technique for the truncated projections of asymmetric-fan-beam transmission imaging IEEE Trans. Nuc. Sci. 42 2292-7
    • (1995) IEEE Trans. Nuc. Sci. , vol.42 , pp. 2292-2297
    • Loncaric, S.1    Chang, W.2    Huang, G.3
  • 15
    • 0037151141 scopus 로고    scopus 로고
    • Image reconstruction from fan-beam projections on less than a short-scan
    • Noo F, Defrise M, Clackdoyle R and Kudo H 2002 Image reconstruction from fan-beam projections on less than a short-scan Phys. Med. Biol. 47 2525-46
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2525-2546
    • Noo, F.1    Defrise, M.2    Clackdoyle, R.3    Kudo, H.4
  • 16
    • 4544351987 scopus 로고    scopus 로고
    • A two-step Hilbert transform method for 2D image recontruction
    • Noo F, Clackdoyle R and Pack J D 2004 A two-step Hilbert transform method for 2D image recontruction Phys. Med. Biol. 49 3903-23
    • (2004) Phys. Med. Biol. , vol.49 , pp. 3903-3923
    • Noo, F.1    Clackdoyle, R.2    Pack, J.D.3
  • 17
    • 4644320732 scopus 로고    scopus 로고
    • A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans
    • Pan X, Xia D, Zou Y and Yu L 2004 A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans Phys. Med. Biol. 49 4349-69
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4349-4369
    • Pan, X.1    Xia, D.2    Zou, Y.3    Yu, L.4
  • 19
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstruction
    • Tuy H K 1983 An inversion formula for cone-beam reconstruction SIAM J. Appl. Math. 43 546-52
    • (1983) SIAM J. Appl. Math. , vol.43 , pp. 546-552
    • Tuy, H.K.1
  • 20
    • 12744260178 scopus 로고    scopus 로고
    • Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data
    • Zhuang T, Leng S, Nett B E and Chen G-H 2004 Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data Phys. Med. Biol. 49 5489-503
    • (2004) Phys. Med. Biol. , vol.49 , pp. 5489-5503
    • Zhuang, T.1    Leng, S.2    Nett, B.E.3    Chen, G.-H.4
  • 21
    • 1642569142 scopus 로고    scopus 로고
    • Exact image reconstruction on Pi-lines from minimum data in helical cone-beam CT
    • Zou Y and Pan X 2004a Exact image reconstruction on Pi-lines from minimum data in helical cone-beam CT Phys. Med. Biol. 49 941-59
    • (2004) Phys. Med. Biol. , vol.49 , pp. 941-959
    • Zou, Y.1    Pan, X.2
  • 22
    • 3242756880 scopus 로고    scopus 로고
    • Image reconstruction on Pi-lines by use of filtered backprojection in helical cone-beam CT
    • Zou Y and Pan X 2004b Image reconstruction on Pi-lines by use of filtered backprojection in helical cone-beam CT Phys. Med. Biol. 49 2717-31
    • (2004) Phys. Med. Biol. , vol.49 , pp. 2717-2731
    • Zou, Y.1    Pan, X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.