메뉴 건너뛰기




Volumn 20, Issue SUPPL. 1, 2009, Pages

Characterization of surface modified polyester fabric

Author keywords

[No Author keywords available]

Indexed keywords

BURST STRENGTH; CYTOTOXIC; DIP COATING TECHNIQUES; FIBROBLAST CELLS; FLUOROPOLYMER; HAEMOCOMPATIBILITY; IN-VITRO; MECHANICAL PERFORMANCE; PET FABRICS; POLYESTER FABRIC; POLYVINYLIDINE FLUORIDES; PROSTHETIC HEART VALVE; SEWING RING; SURFACE COATINGS; SURFACE MODIFICATION; SURFACE-MODIFIED; TISSUE RESPONSE; VASCULAR GRAFTS; WATER PERMEABILITY;

EID: 58849107652     PISSN: 09574530     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10856-008-3502-6     Document Type: Conference Paper
Times cited : (12)

References (17)
  • 1
    • 0022181120 scopus 로고
    • Evaluation of arterial prostheses in a baboon ex vivo shunt: The effect of graft material and flow on platelet deposition
    • DOI 10.1016/0002-9610(85)90116-3
    • J Eldrup-Jorgensen WC Mackey RJ Connolly JL Mccullough K Ramberg V Gavris TF O'donnell AD Callow 1985 Am. J. Surg. 150 185 10.1016/0002-9610(85)90116-3 1:STN:280:DyaL2M3ns12ntg%3D%3D 3161349 (Pubitemid 16250933)
    • (1985) American Journal of Surgery , vol.150 , Issue.2 , pp. 185-190
    • Eldrup-Jorgensen, J.1    Mackey, W.C.2    Connolly, R.J.3
  • 4
    • 0028954409 scopus 로고
    • 10.1111/j.1525-1594.1995.tb02238.x 1:STN:280:DyaK2M3mtVahtw%3D%3D 7741642
    • Y Noishiki Y Tomizawa Y Yamane A Matsumoto 1995 Artif. Organs 19 7 10.1111/j.1525-1594.1995.tb02238.x 1:STN:280:DyaK2M3mtVahtw%3D%3D 7741642
    • (1995) Artif. Organs , vol.19 , pp. 7
    • Noishiki, Y.1    Tomizawa, Y.2    Yamane, Y.3    Matsumoto, A.4
  • 5
    • 0034080797 scopus 로고    scopus 로고
    • Small diameter vascular prosthesis with a nonthrombogenic phospholipid polymer surface: Preliminary study of a new concept for functioning in the absence of pseudo- or neointima formation
    • DOI 10.1046/j.1525-1594.2000.06433.x
    • T Yoneyama M Ito K Sugihara K Ishihara N Nakabayashi 2000 Artif. Organs 24 23 10.1046/j.1525-1594.2000.06433.x 1:CAS:528:DC%2BD3cXivVehsb4%3D 10677153 (Pubitemid 30186718)
    • (2000) Artificial Organs , vol.24 , Issue.1 , pp. 23-28
    • Yoneyama, T.1    Ito, M.2    Sugihara, K.3    Ishihara, K.4    Nakabayashi, N.5
  • 6
    • 0037086734 scopus 로고    scopus 로고
    • The vascular prosthesis without pseudointima prepared by antithrombogenic phospholipid polymer
    • DOI 10.1016/S0142-9612(01)00268-X, PII S014296120100268X
    • T Yoneyama K Sugihara K Ishihara Y Iwasaki N Nakabayashi 2002 Biomaterials 23 145 10.1016/S0142-9612(01)00268-X (Pubitemid 34037082)
    • (2002) Biomaterials , vol.23 , Issue.6 , pp. 1455-1459
    • Yoneyama, T.1    Sugihara, K.-I.2    Ishihara, K.3    Iwasaki, Y.4    Nakabayashi, N.5
  • 11
    • 75049084780 scopus 로고    scopus 로고
    • U.S. Patent 7
    • S.W. Shalaby, U.S. Patent 7,348,364, 2008
    • (2008) , vol.348 , Issue.364
    • Shalaby, S.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.