메뉴 건너뛰기




Volumn 15, Issue 6, 2001, Pages 679-683

Evaluation of thrombogenicity of fluoropassivated polyester patches following carotid endarterectomy

Author keywords

[No Author keywords available]

Indexed keywords

POLYESTER;

EID: 0035205238     PISSN: 08905096     EISSN: None     Source Type: Journal    
DOI: 10.1007/s100160010129     Document Type: Article
Times cited : (16)

References (19)
  • 3
    • 0030938590 scopus 로고    scopus 로고
    • Geometric dimension changes with carotid endarterectomy reconstruction
    • (1997) J Vasc Surg , vol.25 , pp. 488-498
    • Archie, J.P.1
  • 4
    • 0032901166 scopus 로고    scopus 로고
    • Clinical and experimental demonstration of complete healing of porous Dacron patch grafts used for closure of the arteriotomy after carotid endarterectomy
    • (1999) Ann Vasc Surg , vol.13 , pp. 313-317
    • Shi, Q.1    Wu, M.H.2    Sauvage, L.R.3
  • 8
    • 0031106856 scopus 로고    scopus 로고
    • Acute thrombogenicity of intact and injured natural blood conduits versus synthetic conduits, neutrophil, platelet, and fibrinogen adsorption under various shear-rate conditions
    • DOI: 10.1002/(SICI)1097-4636(19970315)34:4>477::AID-JBM8<3.0.CO;2-H
    • (1997) J Biomed Mater Res , vol.34 , pp. 477-485
    • Merhi, Y.1    King, M.2    Guidoin, R.3
  • 13
    • 0021281283 scopus 로고
    • Failure of ticlopidine to inhibit depostion of indium-111 labelled platelets on Dacron prosthetic surfaces in humans
    • (1984) Circulation , vol.69 , pp. 677-696
    • Stratton, J.R.1    Ritchie, J.L.2
  • 15
    • 0031446986 scopus 로고    scopus 로고
    • Expanded polytetra fluoroethylene (ePTFE) vascular graft loses its thrombogenicity six months after implantation
    • DOI: 10.1016/S0049-3848(97)00278-8
    • (1997) Thromb Res , vol.88 , pp. 427-433
    • Ariyoshi, H.1    Okuyama, M.2    Okahara, K.3