메뉴 건너뛰기




Volumn 31, Issue 1, 2009, Pages 26-35

Evaluation and performance characteristics of the coagulation system: ACL TOP analyzer - HemosIL reagents

Author keywords

ACL TOP; Coagulation analyzer; Evaluation; HemosIL reagents

Indexed keywords

BLOOD CLOTTING FACTOR 7; BLOOD CLOTTING FACTOR 8; FIBRINOGEN; PROTEIN C; REAGENT;

EID: 58449134379     PISSN: 17515521     EISSN: 1751553X     Source Type: Journal    
DOI: 10.1111/j.1751-553X.2007.00999.x     Document Type: Article
Times cited : (42)

References (20)
  • 1
    • 34547934654 scopus 로고    scopus 로고
    • Evaluation and performance characteristics of the automated coagulation analyzer ACL TOP
    • Appert-Flory A., Fischer F., Jambou D. Toulon P. (2007) Evaluation and performance characteristics of the automated coagulation analyzer ACL TOP. Thrombosis Research 120, 733 743.
    • (2007) Thrombosis Research , vol.120 , pp. 733-743
    • Appert-Flory, A.1    Fischer, F.2    Jambou, D.3    Toulon, P.4
  • 2
    • 11044238614 scopus 로고    scopus 로고
    • Monitoring haemophilia severity and treatment: New or old laboratory tests?
    • Barrowcliffe T.W. (2004) Monitoring haemophilia severity and treatment: new or old laboratory tests? Haemophilia 10 (Suppl. 4 109 114.
    • (2004) Haemophilia , vol.10 , Issue.4 , pp. 109-114
    • Barrowcliffe, T.W.1
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M. Altman D.J. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1, 307 310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.J.2
  • 4
    • 11044234583 scopus 로고    scopus 로고
    • Essential issues of laboratory investigation for patients with haemophilia and bleeding disorders
    • Chuansumrit A., McCraw A. Preston E.F. (2004) Essential issues of laboratory investigation for patients with haemophilia and bleeding disorders. Haemophilia 10, 105 108.
    • (2004) Haemophilia , vol.10 , pp. 105-108
    • Chuansumrit, A.1    McCraw, A.2    Preston, E.F.3
  • 5
    • 33745551242 scopus 로고
    • Gerinnungsphysiologische Schnellmethode zur Bestimmung des Fibrinogens
    • Clauss A. (1957) Gerinnungsphysiologische Schnellmethode zur Bestimmung des Fibrinogens. Acta Haematologica 17, 237 246.
    • (1957) Acta Haematologica , vol.17 , pp. 237-246
    • Clauss, A.1
  • 7
    • 33744965258 scopus 로고    scopus 로고
    • Evaluation of the automated coagulation analyser ACL TOP (Instrumentation Laboratory)
    • Eschwège V., Catillon C. Robert A. (2006) Evaluation of the automated coagulation analyser ACL TOP (Instrumentation Laboratory). Annales de Biologie Clinique 64, 259 264.
    • (2006) Annales de Biologie Clinique , vol.64 , pp. 259-264
    • Eschwège, V.1    Catillon, C.2    Robert, A.3
  • 8
  • 9
    • 0036720548 scopus 로고    scopus 로고
    • Evaluation and performance characteristics of the STA-R coagulation analyzer
    • Flanders M.M., Crist R., Safapour S. Rodgers G.M. (2002) Evaluation and performance characteristics of the STA-R coagulation analyzer. Clinical Chemistry 48, 1622 1624.
    • (2002) Clinical Chemistry , vol.48 , pp. 1622-1624
    • Flanders, M.M.1    Crist, R.2    Safapour, S.3    Rodgers, G.M.4
  • 10
    • 0141763732 scopus 로고    scopus 로고
    • Method comparison: Correlation is not enough to decide about agreement and clinical accuracy
    • Meijer P. (2003) Method comparison: correlation is not enough to decide about agreement and clinical accuracy. Thrombosis and Haemostasis 90, 555 556.
    • (2003) Thrombosis and Haemostasis , vol.90 , pp. 555-556
    • Meijer, P.1
  • 11
    • 33751209473 scopus 로고    scopus 로고
    • Performance goals for the laboratory testing of antithrombin, protein C and protein S
    • Meijer P., Haverkate F. Kluft C. (2006) Performance goals for the laboratory testing of antithrombin, protein C and protein S. Thrombosis and Haemostasis 96, 584 589.
    • (2006) Thrombosis and Haemostasis , vol.96 , pp. 584-589
    • Meijer, P.1    Haverkate, F.2    Kluft, C.3
  • 18
    • 0028650372 scopus 로고
    • Automation and quality control in the coagulation laboratory
    • Walenga J.M. Fareed J. (1994) Automation and quality control in the coagulation laboratory. Clinics in Laboratory Medicine 14, 709 728.
    • (1994) Clinics in Laboratory Medicine , vol.14 , pp. 709-728
    • Walenga, J.M.1    Fareed, J.2
  • 20
    • 0009005114 scopus 로고    scopus 로고
    • Quality assessment of haemostatic assays and external quality assessment schemes
    • In: eds. J. Jespersen, R.M. Bertina. F. Haverkate. 2nd revised edition of ECAT assay procedures, pp. Kluwer Academic Publishers, Dordrecht, The Netherlands.
    • Woods T.A.L., Kitchen S. Preston F.E. (1999) Quality assessment of haemostatic assays and external quality assessment schemes. In : Laboratory Techniques in Thrombosis - A Manual (eds J. Jespersen, R.M. Bertina F. Haverkate 2nd revised edition of ECAT assay procedures, pp. 29 36. Kluwer Academic Publishers, Dordrecht, The Netherlands.
    • (1999) Laboratory Techniques in Thrombosis - A Manual , pp. 29-36
    • Woods, T.A.L.1    Kitchen, S.2    Preston, F.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.