메뉴 건너뛰기




Volumn 79, Issue 1, 2009, Pages 14-16

Cold and hot snare endoscopic techniques for removal of the bravo pH monitoring capsule

Author keywords

Bravo capsule; Bravo capsule removal; Cold and hot snare endoscopic techniques

Indexed keywords

ARTICLE; CAPSULE ENDOSCOPE; CARDIOESOPHAGOMYOTOMY; CASE REPORT; COLD SNARE PROCEDURE; DEVICE REMOVAL; ENDOSCOPIC POLYPECTOMY; GASTROESOPHAGEAL REFLUX; HOT SNARE PROCEDURE; HUMAN; MONITORING; PRIORITY JOURNAL; THORAX PAIN;

EID: 58349094973     PISSN: 00122823     EISSN: None     Source Type: Journal    
DOI: 10.1159/000194945     Document Type: Article
Times cited : (6)

References (12)
  • 4
    • 33947605125 scopus 로고    scopus 로고
    • Minimizing endoscopic complications - gastric and esophageal physiologic testing
    • Benjamin B, Maher KA: Minimizing endoscopic complications - gastric and esophageal physiologic testing. Gastrointest Endosc Clin N Am 2007; 17: 41-46.
    • (2007) Gastrointest Endosc Clin N Am , vol.17 , pp. 41-46
    • Benjamin, B.1    Maher, K.A.2
  • 5
    • 33745524094 scopus 로고    scopus 로고
    • Bravo capsule induction of esophageal hypercontractility and chest pain
    • Tharavej C, Hagen JA, Portale G, et al: Bravo capsule induction of esophageal hypercontractility and chest pain. Surg Endosc 2006; 20: 783-786.
    • (2006) Surg Endosc , vol.20 , pp. 783-786
    • Tharavej, C.1    Hagen, J.A.2    Portale, G.3
  • 7
    • 22144491540 scopus 로고    scopus 로고
    • Wireless oesophageal pH monitoring: Feasibility, safety and normal values in healthy subjects
    • Wenner J, Jonsson F, Johansson J, et al: Wireless oesophageal pH monitoring: feasibility, safety and normal values in healthy subjects. Scand J Gastroenterol 2005; 40: 768-774.
    • (2005) Scand J Gastroenterol , vol.40 , pp. 768-774
    • Wenner, J.1    Jonsson, F.2    Johansson, J.3
  • 8
    • 27844561482 scopus 로고    scopus 로고
    • Patients with functional heartburn are more likely to report retrosternal discomfort during wireless pH monitoring
    • Lee YC, Wang HP, Chiu HM, Huang SP, Tu CH, Wu MS, Lin JT: Patients with functional heartburn are more likely to report retrosternal discomfort during wireless pH monitoring. Gastrointest Endosc 2005; 62: 834-841.
    • (2005) Gastrointest Endosc , vol.62 , pp. 834-841
    • Lee, Y.C.1    Wang, H.P.2    Chiu, H.M.3    Huang, S.P.4    Tu, C.H.5    Wu, M.S.6    Lin, J.T.7
  • 9
    • 29244463852 scopus 로고    scopus 로고
    • US Food and Drug Administration, Center for Devices and Radiologic Health. Esophageal perforation after placement of wireless Bravo pH probe
    • available at
    • Fajardo NR, Wise JL, Locke GR 3rd, Murray JA, Talley NJ: US Food and Drug Administration, Center for Devices and Radiologic Health. Esophageal perforation after placement of wireless Bravo pH probe. Gastrointest Endosc 2006; 63: 184-185 (available at: http://www.accessdata.fda.gov/scripts/cdrh/ cfdocs/cfMAUDE/Detail.CFM?MDRFOI-ID=1032148).
    • (2006) Gastrointest Endosc , vol.63 , pp. 184-185
    • Fajardo, N.R.1    Wise, J.L.2    Locke 3rd, G.R.3    Murray, J.A.4    Talley, N.J.5
  • 11
    • 13944257383 scopus 로고    scopus 로고
    • The role of pH monitoring in extraesophageal gastroesophageal reflux disease
    • Ahmed T, Vaezi MF: The role of pH monitoring in extraesophageal gastroesophageal reflux disease. Gastrointest Endoscopy Clin N Am 2005; 15: 319-331.
    • (2005) Gastrointest Endoscopy Clin N Am , vol.15 , pp. 319-331
    • Ahmed, T.1    Vaezi, M.F.2
  • 12
    • 33749998678 scopus 로고    scopus 로고
    • Endoscopic removal of the wireless pH monitoring capsule in patients with severe discomfort
    • Prakash C, Jonnalagadda S, Azar R, Clouse RE: Endoscopic removal of the wireless pH monitoring capsule in patients with severe discomfort. Gastrointest Endosc 2006; 64: 828-832.
    • (2006) Gastrointest Endosc , vol.64 , pp. 828-832
    • Prakash, C.1    Jonnalagadda, S.2    Azar, R.3    Clouse, R.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.