Volumn 64, Issue 5, 2006, Pages 828-832

Endoscopic removal of the wireless pH monitoring capsule in patients with severe discomfort

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; ENDOSCOPE; ENDOSCOPIC SURGERY; FEMALE; FOREIGN BODY; GASTROINTESTINAL SYMPTOM; HEMOSTASIS; HUMAN; MALE; MEDICAL INSTRUMENTATION; MONITORING; ODYNOPHAGIA; PH; PRIORITY JOURNAL; THORAX PAIN; WIRELESS PH MONITORING CAPSULE;

EID: 33749998678     PISSN: 00165107     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gie.2006.06.006     Document Type: Article
Times cited : (17)

References (17)
  • 1
    • 0038701753 scopus 로고    scopus 로고
    • Ambulatory esophageal pH monitoring using a wireless system
    • Pandolfino J.E., Richter J.E., Ours T., et al. Ambulatory esophageal pH monitoring using a wireless system. Am J Gastroenterol 98 (2003) 740-749
    • (2003) Am J Gastroenterol , vol.98 , pp. 740-749
    • Pandolfino, J.E.1    Richter, J.E.2    Ours, T.3
  • 2
    • 22144491540 scopus 로고    scopus 로고
    • Wireless oesophageal pH monitoring: feasibility, safety and normal values in healthy subjects
    • Wenner J., Johnsson F., Johansson J., et al. Wireless oesophageal pH monitoring: feasibility, safety and normal values in healthy subjects. Scand J Gastroenterol 40 (2005) 768-774
    • (2005) Scand J Gastroenterol , vol.40 , pp. 768-774
    • Wenner, J.1    Johnsson, F.2    Johansson, J.3
  • 3
    • 16844370817 scopus 로고    scopus 로고
    • Value of extended recording time with wireless pH monitoring in evaluating gastroesophageal reflux disease
    • Prakash C., and Clouse R.E. Value of extended recording time with wireless pH monitoring in evaluating gastroesophageal reflux disease. Clin Gastroenterol Hepatol 3 (2005) 329-334
    • (2005) Clin Gastroenterol Hepatol , vol.3 , pp. 329-334
    • Prakash, C.1    Clouse, R.E.2
  • 4
    • 33644776039 scopus 로고    scopus 로고
    • Prakash C, Clouse RE. Wireless pH monitoring in patients with noncardiac chest pain. Am J Gastroenterol 2006;101:446-52.
  • 5
    • 33644990223 scopus 로고    scopus 로고
    • Day-to-day variability in acid reflux patterns using the BRAVO pH monitoring system
    • Ahlawat S., Novak D.J., Williams D.C., et al. Day-to-day variability in acid reflux patterns using the BRAVO pH monitoring system. J Clin Gastroenterol 40 (2006) 20-24
    • (2006) J Clin Gastroenterol , vol.40 , pp. 20-24
    • Ahlawat, S.1    Novak, D.J.2    Williams, D.C.3
  • 6
    • 33645814230 scopus 로고    scopus 로고
    • Wireless esophageal pH monitoring: new technique means new questions
    • Bhat Y.M., McGrath K.M., and Bielefeldt K. Wireless esophageal pH monitoring: new technique means new questions. J Clin Gastroenterol 40 (2006) 116-121
    • (2006) J Clin Gastroenterol , vol.40 , pp. 116-121
    • Bhat, Y.M.1    McGrath, K.M.2    Bielefeldt, K.3
  • 7
    • 0025315805 scopus 로고
    • Ambulatory 24 hour intraoesophageal pH and pressure recordings v provocation tests in the diagnosis of chest pain of oesophageal origin
    • Ghillebert G., Janssens J., Vantrappen G., et al. Ambulatory 24 hour intraoesophageal pH and pressure recordings v provocation tests in the diagnosis of chest pain of oesophageal origin. Gut 31 (1990) 738-744
    • (1990) Gut , vol.31 , pp. 738-744
    • Ghillebert, G.1    Janssens, J.2    Vantrappen, G.3
  • 8
    • 0023904450 scopus 로고
    • The symptom index: a clinically important parameter of ambulatory 24-hour esophageal pH monitoring
    • Wiener G.J., Richter J.E., Copper J.B., et al. The symptom index: a clinically important parameter of ambulatory 24-hour esophageal pH monitoring. Am J Gastroenterol 83 (1988) 358-361
    • (1988) Am J Gastroenterol , vol.83 , pp. 358-361
    • Wiener, G.J.1    Richter, J.E.2    Copper, J.B.3
  • 9
    • 1542329561 scopus 로고    scopus 로고
    • Successful oesophageal pH monitoring with a catheter-free system
    • Ward E.M., Devalult K.R., Bouras E.P., et al. Successful oesophageal pH monitoring with a catheter-free system. Aliment Pharmacol Ther 19 (2004) 449-454
    • (2004) Aliment Pharmacol Ther , vol.19 , pp. 449-454
    • Ward, E.M.1    Devalult, K.R.2    Bouras, E.P.3
  • 10
    • 16844374098 scopus 로고    scopus 로고
    • Bravo pH vs. ambulatory 24 hour catheter pH monitoring: a prospective assessment of patient satisfaction, discomfort and impairment of daily activities
    • [abstract]
    • Ours T., and Richter J. Bravo pH vs. ambulatory 24 hour catheter pH monitoring: a prospective assessment of patient satisfaction, discomfort and impairment of daily activities. [abstract]. Gastroenterology 122 (2002) A-580
    • (2002) Gastroenterology , vol.122
    • Ours, T.1    Richter, J.2
  • 11
    • 0027318333 scopus 로고
    • "Pinch" injury during overtube placement in upper endoscopy
    • Berkelhammer C., Madhav G., Lyon S., et al. "Pinch" injury during overtube placement in upper endoscopy. Gastrointest Endosc 39 (1993) 186-187
    • (1993) Gastrointest Endosc , vol.39 , pp. 186-187
    • Berkelhammer, C.1    Madhav, G.2    Lyon, S.3
  • 12
    • 0027223427 scopus 로고
    • Complications associated with endoscopic band ligation of esophageal varices
    • Johnson P.A., Campbell D.R., Antonson C.W., et al. Complications associated with endoscopic band ligation of esophageal varices. Gastrointest Endosc 39 (1993) 181-185
    • (1993) Gastrointest Endosc , vol.39 , pp. 181-185
    • Johnson, P.A.1    Campbell, D.R.2    Antonson, C.W.3
  • 13
    • 0028954467 scopus 로고
    • Mucosal stripping: a complication of push enteroscopy
    • Yang R., and Laine L. Mucosal stripping: a complication of push enteroscopy. Gastrointest Endosc 41 (1995) 156-158
    • (1995) Gastrointest Endosc , vol.41 , pp. 156-158
    • Yang, R.1    Laine, L.2
  • 14
    • 13744254648 scopus 로고    scopus 로고
    • Bravo capsule pH monitoring
    • Pandolfino J.E. Bravo capsule pH monitoring. Am J Gastroenterol 100 (2005) 8-10
    • (2005) Am J Gastroenterol , vol.100 , pp. 8-10
    • Pandolfino, J.E.1
  • 15
    • 0026649856 scopus 로고
    • Cold snare excision of small colorectal polyps
    • Tappero G., Gaia E., De Giuli P., et al. Cold snare excision of small colorectal polyps. Gastrointest Endosc 38 (1992) 310-313
    • (1992) Gastrointest Endosc , vol.38 , pp. 310-313
    • Tappero, G.1    Gaia, E.2    De Giuli, P.3
  • 16
    • 0031300114 scopus 로고    scopus 로고
    • Cold snare excision is a safe method for diminutive colorectal polyps
    • Uno Y., Obara K., Zheng P., et al. Cold snare excision is a safe method for diminutive colorectal polyps. Tohoku J Exp Med 183 (1997) 243-249
    • (1997) Tohoku J Exp Med , vol.183 , pp. 243-249
    • Uno, Y.1    Obara, K.2    Zheng, P.3
  • 17
    • 27844561482 scopus 로고    scopus 로고
    • Patients with functional heartburn are more likely to report retrosternal discomfort during wireless pH monitoring
    • Lee Y., Wang H., Chiu H., et al. Patients with functional heartburn are more likely to report retrosternal discomfort during wireless pH monitoring. Gastrointest Endosc 62 (2005) 834-841
    • (2005) Gastrointest Endosc , vol.62 , pp. 834-841
    • Lee, Y.1    Wang, H.2    Chiu, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.