메뉴 건너뛰기




Volumn 136, Issue 1, 2009, Pages 177-185

Development of a microelectrode array sensing platform for combination electrochemical and spectrochemical aqueous ion testing

Author keywords

Electrochemical cell; Microelectrode array; Photolithography; Potassium ferricyanide; Spectrochemical analysis

Indexed keywords

BIOCHEMISTRY; COPPER; ELECTRIC BATTERIES; ELECTROCHEMICAL CELLS; ELECTRODES; ELECTROLYTIC CELLS; ENVIRONMENTAL TESTING; GLASS; HEAVY METALS; INDUSTRIAL APPLICATIONS; IONS; METAL IONS; MICROELECTRODES; POLYMERIC GLASS; SENSORS; SPECTRUM ANALYSIS; STRIPPING (DYES); SURFACE DEFECTS;

EID: 58249143779     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2008.10.031     Document Type: Article
Times cited : (31)

References (21)
  • 1
    • 0036738408 scopus 로고    scopus 로고
    • Real-time electrochemical monitoring: toward green analytical chemistry
    • Wang J. Real-time electrochemical monitoring: toward green analytical chemistry. Accounts of Chemical Research 35 (2002) 811-816
    • (2002) Accounts of Chemical Research , vol.35 , pp. 811-816
    • Wang, J.1
  • 2
    • 0033668234 scopus 로고    scopus 로고
    • Microfabricated ultramicroelectrode arrays: developments, advances, and applications in environmental analysis
    • Feeney R., and Kounaves S.P. Microfabricated ultramicroelectrode arrays: developments, advances, and applications in environmental analysis. Electroanalysis 12 (2000) 677-684
    • (2000) Electroanalysis , vol.12 , pp. 677-684
    • Feeney, R.1    Kounaves, S.P.2
  • 3
    • 33846517559 scopus 로고    scopus 로고
    • Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions
    • Berduque A., Lanyon Y.H., Beni V., Herzog G.e., Watson Y.E., Rodgers K., Stam F., Alderman J., and Arrigan D.W.M. Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions. Talanta 71 (2007) 1022-1030
    • (2007) Talanta , vol.71 , pp. 1022-1030
    • Berduque, A.1    Lanyon, Y.H.2    Beni, V.3    Herzog, G.e.4    Watson, Y.E.5    Rodgers, K.6    Stam, F.7    Alderman, J.8    Arrigan, D.W.M.9
  • 5
    • 33845305497 scopus 로고    scopus 로고
    • Determination of trace arsenic with DDTC-Na by cathodic stripping voltammetry in presence of copper ions
    • Piech R., and Kubiak W.W. Determination of trace arsenic with DDTC-Na by cathodic stripping voltammetry in presence of copper ions. Journal of Electroanalytical Chemistry 599 (2007) 59-64
    • (2007) Journal of Electroanalytical Chemistry , vol.599 , pp. 59-64
    • Piech, R.1    Kubiak, W.W.2
  • 6
    • 39649096060 scopus 로고    scopus 로고
    • Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode
    • Giacomino A., Abollino O., Malandrino M., and Mentasti E. Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode. Talanta 75 (2008) 266-273
    • (2008) Talanta , vol.75 , pp. 266-273
    • Giacomino, A.1    Abollino, O.2    Malandrino, M.3    Mentasti, E.4
  • 7
    • 58249140696 scopus 로고    scopus 로고
    • Annual Book of ASTM Standards, Section 11, Water and Environmental Technology.
    • Annual Book of ASTM Standards, Section 11, Water and Environmental Technology.
  • 8
    • 0016805812 scopus 로고
    • Determination of arsenic by anodic stripping voltammetry and differential pulse anodic stripping voltammetry
    • Forsberg G., O'Laughlin J.W., Megargle R.G., and Koirtyohann S.R. Determination of arsenic by anodic stripping voltammetry and differential pulse anodic stripping voltammetry. Analytical Chemistry 47 (1975) 1586-1592
    • (1975) Analytical Chemistry , vol.47 , pp. 1586-1592
    • Forsberg, G.1    O'Laughlin, J.W.2    Megargle, R.G.3    Koirtyohann, S.R.4
  • 10
    • 33646515018 scopus 로고
    • Diffusion controlled current at a stationary finite disk electrode
    • Aoki K., and Osteryoung J. Diffusion controlled current at a stationary finite disk electrode. Journal of Electroanalytical Chemistry 125 (1981) 315-320
    • (1981) Journal of Electroanalytical Chemistry , vol.125 , pp. 315-320
    • Aoki, K.1    Osteryoung, J.2
  • 11
    • 0022672053 scopus 로고
    • Potentiometric stripping determination of heavy metals with carbon fiber and gold microelectrodes
    • Baranski A.S., and Quon H. Potentiometric stripping determination of heavy metals with carbon fiber and gold microelectrodes. Analytical Chemistry 58 (1986) 407-412
    • (1986) Analytical Chemistry , vol.58 , pp. 407-412
    • Baranski, A.S.1    Quon, H.2
  • 12
    • 0025445253 scopus 로고
    • Transient behavior at planar microelectrodes: A comparison of diffusion current at ring, band and disk electrodes
    • Cope D.K., and Tallman D.E. Transient behavior at planar microelectrodes: A comparison of diffusion current at ring, band and disk electrodes. Journal of Electroanalytical Chemistry 285 (1990) 85-92
    • (1990) Journal of Electroanalytical Chemistry , vol.285 , pp. 85-92
    • Cope, D.K.1    Tallman, D.E.2
  • 14
    • 33845378249 scopus 로고
    • Voltammetry at linear gold and platinum microelectrode arrays produced by lithographic techniques
    • Thormann W., Bosch P.v.d., and Bond A.M. Voltammetry at linear gold and platinum microelectrode arrays produced by lithographic techniques. Analytical Chemistry 57 (1985) 2764-2770
    • (1985) Analytical Chemistry , vol.57 , pp. 2764-2770
    • Thormann, W.1    Bosch, P.v.d.2    Bond, A.M.3
  • 15
    • 0031130419 scopus 로고    scopus 로고
    • Characterization of microelectrode arrays by means of electrochemical and surface analysis methods
    • Wittkampf M., Cammann K., Amrein M., and Reichelt R. Characterization of microelectrode arrays by means of electrochemical and surface analysis methods. Sensors and Actuators B Chemical 40 (1997) 79-84
    • (1997) Sensors and Actuators B Chemical , vol.40 , pp. 79-84
    • Wittkampf, M.1    Cammann, K.2    Amrein, M.3    Reichelt, R.4
  • 16
    • 25644454307 scopus 로고    scopus 로고
    • Microelectrode array for isolation of electrode polarization on planar solid electrolytes
    • Dunyushkina L.A., Lu Y., and Adler S.B. Microelectrode array for isolation of electrode polarization on planar solid electrolytes. Journal of the Electrochemical Society 152 (2005) A1668-A1676
    • (2005) Journal of the Electrochemical Society , vol.152
    • Dunyushkina, L.A.1    Lu, Y.2    Adler, S.B.3
  • 17
    • 0011700946 scopus 로고    scopus 로고
    • Electrochemical characterisation and application of multi microelectrode array devices to biological electrochemistry
    • Kudera M., Hill H.A.O., Dobson P.J., Leigh P.A., and McIntire W.S. Electrochemical characterisation and application of multi microelectrode array devices to biological electrochemistry. Sensors 1 (2001) 18-28
    • (2001) Sensors , vol.1 , pp. 18-28
    • Kudera, M.1    Hill, H.A.O.2    Dobson, P.J.3    Leigh, P.A.4    McIntire, W.S.5
  • 18
    • 0033554759 scopus 로고    scopus 로고
    • Multi-element heavy metal ion sensors for aqueous solutions
    • Saban S.B., and Darling R.B. Multi-element heavy metal ion sensors for aqueous solutions. Sensors and Actuators B Chemical 61 (1999) 128-137
    • (1999) Sensors and Actuators B Chemical , vol.61 , pp. 128-137
    • Saban, S.B.1    Darling, R.B.2
  • 19
    • 30144434486 scopus 로고    scopus 로고
    • Combination of ultrasonic extraction and stripping analysis: an effective and reliable way for the determination of Cu and Pb in lubricating oils
    • Munoz R.A.A., Oliveira P.V., and Angnes L.U. Combination of ultrasonic extraction and stripping analysis: an effective and reliable way for the determination of Cu and Pb in lubricating oils. Talanta 68 (2006) 850-856
    • (2006) Talanta , vol.68 , pp. 850-856
    • Munoz, R.A.A.1    Oliveira, P.V.2    Angnes, L.U.3
  • 20
    • 33646558230 scopus 로고    scopus 로고
    • Determination of Se(IV) by anodic stripping voltammetry using gold electrodes made from recordable CDs
    • Pereira C.F., Gonzaga F.B., Guarit́a-Santos A.M., and SouzaDe J.R. Determination of Se(IV) by anodic stripping voltammetry using gold electrodes made from recordable CDs. Talanta 69 (2006) 877-881
    • (2006) Talanta , vol.69 , pp. 877-881
    • Pereira, C.F.1    Gonzaga, F.B.2    Guarit́a-Santos, A.M.3    SouzaDe, J.R.4
  • 21
    • 0027618391 scopus 로고
    • Mercury-free disposable lead sensors based on potentiometric stripping analysis at gold-coated screen-printed electrodes
    • Wang J., and Tiant B. Mercury-free disposable lead sensors based on potentiometric stripping analysis at gold-coated screen-printed electrodes. Analytical Chemistry 65 (1993) 1529-1532
    • (1993) Analytical Chemistry , vol.65 , pp. 1529-1532
    • Wang, J.1    Tiant, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.