메뉴 건너뛰기




Volumn 43, Issue 6, 1998, Pages 765-778

Estimation of systemic vascular bed parameters for artificial heart control

Author keywords

Artificial heart; Kalman filter; Nonlinear models; Parameter estimation; Vascular bed parameters; Ventricular assist device

Indexed keywords

CARDIOVASCULAR SYSTEM; COMPUTER SIMULATION; CONTROL; ESTIMATION; HEMODYNAMICS; KALMAN FILTERING; MATHEMATICAL MODELS;

EID: 0032096937     PISSN: 00189286     EISSN: None     Source Type: Journal    
DOI: 10.1109/9.679017     Document Type: Article
Times cited : (53)

References (26)
  • 1
    • 0026904735 scopus 로고
    • Comparison of algorithms for tracking short-term changes in arterial circulation parameters
    • G. Avanzolini, P. Barbini, and A. Cappello, "Comparison of algorithms for tracking short-term changes in arterial circulation parameters," IEEE Trans. Biomed. Eng., vol. 39, pp. 861-867, 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 861-867
    • Avanzolini, G.1    Barbini, P.2    Cappello, A.3
  • 2
    • 0021702314 scopus 로고
    • Ventricular interaction with the loading system
    • K. Sunagawa, K. Sagawa, and W. L. Maughan, "Ventricular interaction with the loading system," Ann. Biomed. Eng., vol. 12, pp. 163-189, 1984.
    • (1984) Ann. Biomed. Eng. , vol.12 , pp. 163-189
    • Sunagawa, K.1    Sagawa, K.2    Maughan, W.L.3
  • 3
    • 0022781240 scopus 로고
    • Adaptive control technique for artificial hearts
    • T. Kitamura, K. Matsuda, and H. Akashi, "Adaptive control technique for artificial hearts," IEEE Trans. Biomed. Eng., vol. BME-33, pp. 839-844, 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.BME-33 , pp. 839-844
    • Kitamura, T.1    Matsuda, K.2    Akashi, H.3
  • 4
    • 0019230973 scopus 로고
    • A two-stage identification scheme for the determination of the parameters of a model of left heart and systemic circulation
    • J. W. Clark, R. Y. S. Ling, R. Srinivasan, J. S. Cole, and R. C. Pruett, "A two-stage identification scheme for the determination of the parameters of a model of left heart and systemic circulation," IEEE Trans. Biomed. Eng., vol. BME-27, pp. 20-29, 1980.
    • (1980) IEEE Trans. Biomed. Eng. , vol.BME-27 , pp. 20-29
    • Clark, J.W.1    Ling, R.Y.S.2    Srinivasan, R.3    Cole, J.S.4    Pruett, R.C.5
  • 5
    • 0018989155 scopus 로고
    • Quantitative evaluation of the systemic arterial bed by parameter estimation of a simple model
    • B. Deswysen, A. A. Charlier, and M. Gevers, "Quantitative evaluation of the systemic arterial bed by parameter estimation of a simple model," Med. Biol. Eng. Comp., vol. 18, pp. 153-166, 1980.
    • (1980) Med. Biol. Eng. Comp. , vol.18 , pp. 153-166
    • Deswysen, B.1    Charlier, A.A.2    Gevers, M.3
  • 6
    • 0001740359 scopus 로고
    • Die grundform des arteriellen puls
    • O. Frank, "Die grundform des arteriellen puls," Z. Biol., vol. 37, pp. 483-526, 1899.
    • (1899) Z. Biol. , vol.37 , pp. 483-526
    • Frank, O.1
  • 8
    • 0017367635 scopus 로고
    • Parameter estimation of a simple mode of the left ventricle and of the systemic vascular bed, with particular attention to the physical meaning of the left ventricle parameters
    • B. Deswysen, "Parameter estimation of a simple mode of the left ventricle and of the systemic vascular bed, with particular attention to the physical meaning of the left ventricle parameters," IEEE Trans. Biomed. Eng., vol. BME-24, pp. 29-36, 1977.
    • (1977) IEEE Trans. Biomed. Eng. , vol.BME-24 , pp. 29-36
    • Deswysen, B.1
  • 9
    • 0003014965 scopus 로고    scopus 로고
    • Identification scheme for cardiovascular parameter estimation
    • San Francisco, CA, June 30-July 5
    • Y.-C. Yu, J. R. Boston, M. Simaan, and J. F. Antaki, "Identification scheme for cardiovascular parameter estimation," Preprints IFAC 13th World Congr., San Francisco, CA, June 30-July 5, 1996, vol. B, pp. 417-422.
    • (1996) Preprints IFAC 13th World Congr. , vol.B , pp. 417-422
    • Yu, Y.-C.1    Boston, J.R.2    Simaan, M.3    Antaki, J.F.4
  • 10
    • 0018082184 scopus 로고
    • The ventricular pressure-volume diagram revisited
    • K. Sagawa, "The ventricular pressure-volume diagram revisited," Circ. Res., vol. 43, pp. 677-687, 1978.
    • (1978) Circ. Res. , vol.43 , pp. 677-687
    • Sagawa, K.1
  • 12
    • 0025410067 scopus 로고
    • An adaptive aortic pressure observer for the Penn state electric ventricular assist device
    • U. Tasch, J. W. Koontz, M. A. Ignatoski, and D. B. Geseloeitz, "An adaptive aortic pressure observer for the Penn state electric ventricular assist device," IEEE Trans. Biomed. Eng., vol. 37, pp. 374-383, 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 374-383
    • Tasch, U.1    Koontz, J.W.2    Ignatoski, M.A.3    Geseloeitz, D.B.4
  • 13
    • 0027595939 scopus 로고
    • Identification algorithm for systemic arterial parameters with application to total artificial heart control
    • T. L. Ruchti, R. H. Brown, D. C. Jeutter, and X. Feng, "Identification algorithm for systemic arterial parameters with application to total artificial heart control," Ann. Biomed. Eng., vol. 21, pp. 221-236, 1993.
    • (1993) Ann. Biomed. Eng. , vol.21 , pp. 221-236
    • Ruchti, T.L.1    Brown, R.H.2    Jeutter, D.C.3    Feng, X.4
  • 14
    • 0022045928 scopus 로고
    • Adaptive control of left ventricular bypass assist devices
    • B. C. McInnis, Z.-W. Guo, P. C. Lu, and J.-C. Wang, "Adaptive control of left ventricular bypass assist devices," IEEE Trans. Automat. Contr., vol. AC-30, pp. 322-329, 1985.
    • (1985) IEEE Trans. Automat. Contr. , vol.AC-30 , pp. 322-329
    • McInnis, B.C.1    Guo, Z.-W.2    Lu, P.C.3    Wang, J.-C.4
  • 15
    • 0025852503 scopus 로고
    • Investigation of parameter estimator and adaptive controller for assist pump by computer simulation
    • T. Shimooka, Y. Mitamura, and T. Yuhta, "Investigation of parameter estimator and adaptive controller for assist pump by computer simulation," Artif. Organs, vol. 15, pp. 119-128, 1991.
    • (1991) Artif. Organs , vol.15 , pp. 119-128
    • Shimooka, T.1    Mitamura, Y.2    Yuhta, T.3
  • 16
    • 0025456162 scopus 로고
    • A nonlinear model of the arterial system incorporating a pressure-dependent compliance
    • J. K.-J. Li, C. Ting, and G. M. Drzewiecki, "A nonlinear model of the arterial system incorporating a pressure-dependent compliance," IEEE Trans. Biomed. Eng., vol. 37, pp. 673-678, 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 673-678
    • Li, J.K.-J.1    Ting, C.2    Drzewiecki, G.M.3
  • 17
    • 0023227787 scopus 로고
    • Total systemic arterial compliance and aortic characteristic impedance in the dog as a function of pressure: A model based study
    • B. Burattini, G. Gnudi, N. Westerhof, and S. Fioretti, "Total systemic arterial compliance and aortic characteristic impedance in the dog as a function of pressure: A model based study," Comput. Biomed Res., vol. 20, pp. 154-165, 1987.
    • (1987) Comput. Biomed Res. , vol.20 , pp. 154-165
    • Burattini, B.1    Gnudi, G.2    Westerhof, N.3    Fioretti, S.4
  • 21
    • 0017242299 scopus 로고
    • Identifiability of linear and nonlinear dynamical systems
    • M. S. Grewal and K. Glover, "Identifiability of linear and nonlinear dynamical systems," IEEE Trans. Automat. Contr., vol. AC-21, pp. 322-329, 1976.
    • (1976) IEEE Trans. Automat. Contr. , vol.AC-21 , pp. 322-329
    • Grewal, M.S.1    Glover, K.2
  • 22
    • 0016803779 scopus 로고
    • Arterial impedance as ventricular afterload
    • W. R. Milnor, "Arterial impedance as ventricular afterload," Circ. Res., vol. 36, pp. 565-570, 1975.
    • (1975) Circ. Res. , vol.36 , pp. 565-570
    • Milnor, W.R.1
  • 23
    • 0017401195 scopus 로고
    • Input impedance of the systemic circulation in man
    • W. W. Nichols, C. R. Conti, W. E. Walker, and W. R. Milnor, "Input impedance of the systemic circulation in man," Circ. Res., vol. 40, pp. 451-458, 1977.
    • (1977) Circ. Res. , vol.40 , pp. 451-458
    • Nichols, W.W.1    Conti, C.R.2    Walker, W.E.3    Milnor, W.R.4
  • 24
    • 0018435192 scopus 로고
    • Asymptotic behavior of the extended Kalman filter as a parameter estimator for linear systems
    • L. Ljung, "Asymptotic behavior of the extended Kalman filter as a parameter estimator for linear systems," IEEE Trans. Automat. Contr., vol. AC-24, pp. 36-50, 1979.
    • (1979) IEEE Trans. Automat. Contr. , vol.AC-24 , pp. 36-50
    • Ljung, L.1
  • 25
    • 84864123850 scopus 로고
    • Suboptimal state estimation for continuous-time nonlinear systems from discrete noisy measurements
    • M. Athans, R. P. Wishner, and A. Bertolini, "Suboptimal state estimation for continuous-time nonlinear systems from discrete noisy measurements," IEEE Trans. Automat. Contr., vol. AC-13, pp. 504-514, 1968.
    • (1968) IEEE Trans. Automat. Contr. , vol.AC-13 , pp. 504-514
    • Athans, M.1    Wishner, R.P.2    Bertolini, A.3
  • 26
    • 0025500066 scopus 로고
    • On-line estimation for a left heart assist device
    • T. Kitamura and D. R. Gross, "On-line estimation for a left heart assist device," IEEE Trans. Biomed. Eng., vol. 37, pp. 968-974, 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 968-974
    • Kitamura, T.1    Gross, D.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.