메뉴 건너뛰기




Volumn 122, Issue 6, 2008, Pages

A novel method of distal end-tidal CO2 capnography in intubated infants: Comparison with Arterial CO2 and with proximal mainstream end-tidal CO2

Author keywords

End tidal carbon dioxide; Mainstream ETCO2; Microstream technique; Preterm infants; Sidestream ETCO2

Indexed keywords

ARTERIAL CARBON DIOXIDE TENSION; ARTICLE; CAPNOGRAPHY; CLINICAL ARTICLE; COMPARATIVE STUDY; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; DISTAL END TIDAL CARBON DIOXIDE TENSION; DOUBLE LUMEN TUBE; END TIDAL CARBON DIOXIDE TENSION; ENDOTRACHEAL INTUBATION; HUMAN; MICROSTREAM CAPNOGRAPHY; NEWBORN; NEWBORN INTENSIVE CARE; PRIORITY JOURNAL; PROXIMAL MAINSTREAM END TIDAL CARBON DIOXIDE TENSION; ARTIFICIAL VENTILATION; BLOOD; BLOOD GAS ANALYSIS; EVALUATION; FEMALE; FOLLOW UP; ISRAEL; LUNG GAS EXCHANGE; MALE; METHODOLOGY; NEONATAL RESPIRATORY DISTRESS SYNDROME; PROBABILITY; PROSPECTIVE STUDY; RISK ASSESSMENT; SENSITIVITY AND SPECIFICITY; STATISTICAL MODEL; TIDAL VOLUME; TRANSCUTANEOUS OXYGEN MONITORING;

EID: 58249091790     PISSN: 00314005     EISSN: 10984275     Source Type: Journal    
DOI: 10.1542/peds.2008-1300     Document Type: Article
Times cited : (58)

References (24)
  • 1
    • 0029035509 scopus 로고
    • Hypocarbia before surfactant therapy appears to increase bronchopulmonary dysplasia risk in infants with respiratory distress syndrome
    • Garland JS, Buck RK, Allred EN, Leviton A. Hypocarbia before surfactant therapy appears to increase bronchopulmonary dysplasia risk in infants with respiratory distress syndrome. Arch Pediatr Adolesc Med. 1995;149(6):617-622
    • (1995) Arch Pediatr Adolesc Med , vol.149 , Issue.6 , pp. 617-622
    • Garland, J.S.1    Buck, R.K.2    Allred, E.N.3    Leviton, A.4
  • 3
    • 0025817318 scopus 로고
    • Response of cerebral blood volume to changes in arterial carbon dioxide tension in preterm and term infants
    • Wyatt JS, Edwards AD, Cope M, et al. Response of cerebral blood volume to changes in arterial carbon dioxide tension in preterm and term infants. Pediatr Res. 1991;29(6):553-557
    • (1991) Pediatr Res , vol.29 , Issue.6 , pp. 553-557
    • Wyatt, J.S.1    Edwards, A.D.2    Cope, M.3
  • 4
    • 0023025876 scopus 로고
    • Perinatal factors and periventricular-intraventricular hemorrhage in preterm infants
    • Van de Bor M, Van Bel F, Lineman R, Ruys JH. Perinatal factors and periventricular-intraventricular hemorrhage in preterm infants. Am J Dis Child. 1986;140(11):1125-1130
    • (1986) Am J Dis Child , vol.140 , Issue.11 , pp. 1125-1130
    • Van de Bor, M.1    Van Bel, F.2    Lineman, R.3    Ruys, J.H.4
  • 5
    • 0025912580 scopus 로고
    • Transfusion therapy in neonates
    • Strauss RG. Transfusion therapy in neonates. Am J Dis Child. 1991;145(8):904-911
    • (1991) Am J Dis Child , vol.145 , Issue.8 , pp. 904-911
    • Strauss, R.G.1
  • 6
    • 0035722150 scopus 로고    scopus 로고
    • End-tidal carbon dioxide monitoring in pediatrics: Clinical applications
    • Bhende MS. End-tidal carbon dioxide monitoring in pediatrics: clinical applications. J Postgrad Med. 2001;47(3):215-218
    • (2001) J Postgrad Med , vol.47 , Issue.3 , pp. 215-218
    • Bhende, M.S.1
  • 7
    • 33644983368 scopus 로고    scopus 로고
    • The role of carbon dioxide detectors for confirmation of endotracheal tube position
    • vii
    • Wyllie J, Carlo WA. The role of carbon dioxide detectors for confirmation of endotracheal tube position. Clin Perinatol. 2006;33(1):111-119, vii
    • (2006) Clin Perinatol , vol.33 , Issue.1 , pp. 111-119
    • Wyllie, J.1    Carlo, W.A.2
  • 9
    • 0036237725 scopus 로고    scopus 로고
    • Accuracy of a new low-flow sidestream capnography technology in newborns: A pilot study
    • Hagerty JJ, Kleinman ME, Zurakowski D, Lyons AC, Krauss B. Accuracy of a new low-flow sidestream capnography technology in newborns: a pilot study. J Perinatol. 2002;22(3):219-225
    • (2002) J Perinatol , vol.22 , Issue.3 , pp. 219-225
    • Hagerty, J.J.1    Kleinman, M.E.2    Zurakowski, D.3    Lyons, A.C.4    Krauss, B.5
  • 10
    • 0031918293 scopus 로고    scopus 로고
    • Mainstream end-tidal carbon dioxide monitoring in the neonatal intensive care unit
    • Rozycki HJ, Sysyn GD, Marshall MK, Malloy R, Wiswell TE. Mainstream end-tidal carbon dioxide monitoring in the neonatal intensive care unit. Pediatrics. 1998;101(4 pt 1):648-653
    • (1998) Pediatrics , vol.101 , Issue.4 PART 1 , pp. 648-653
    • Rozycki, H.J.1    Sysyn, G.D.2    Marshall, M.K.3    Malloy, R.4    Wiswell, T.E.5
  • 11
    • 0025266828 scopus 로고
    • End-tidal carbon dioxide measurements in critically ill neonates: A comparison of side-stream and mainstream cap-nometers
    • McEvedy BA, McLeod ME, Kirpalani H, Volgyesi GA, Lerman J. End-tidal carbon dioxide measurements in critically ill neonates: a comparison of side-stream and mainstream cap-nometers. Can J Anaesth. 1990;37(3):322-326
    • (1990) Can J Anaesth , vol.37 , Issue.3 , pp. 322-326
    • McEvedy, B.A.1    McLeod, M.E.2    Kirpalani, H.3    Volgyesi, G.A.4    Lerman, J.5
  • 12
    • 0037384489 scopus 로고    scopus 로고
    • Good estimation of arterial carbon dioxide by end-tidal carbon dioxide monitoring in the neonatal intensive care unit
    • Wu CH, Chou HC, Hsieh WS, Chen WK, Huang PY, Tsao PN. Good estimation of arterial carbon dioxide by end-tidal carbon dioxide monitoring in the neonatal intensive care unit. Pediatr Pulmonol. 2003;35(4):292-295
    • (2003) Pediatr Pulmonol , vol.35 , Issue.4 , pp. 292-295
    • Wu, C.H.1    Chou, H.C.2    Hsieh, W.S.3    Chen, W.K.4    Huang, P.Y.5    Tsao, P.N.6
  • 13
    • 0024333593 scopus 로고
    • Comparison of side-stream and mainstream capnometer in infants
    • Pascucci RC, Schena JA, Thompson JE. Comparison of side-stream and mainstream capnometer in infants. Crit Care Med. 1989;17(6):560-562
    • (1989) Crit Care Med , vol.17 , Issue.6 , pp. 560-562
    • Pascucci, R.C.1    Schena, J.A.2    Thompson, J.E.3
  • 14
    • 0024405425 scopus 로고
    • Discrepancies between transcutaneous and end-tidal carbon dioxide monitoring in the critically ill neonate with respiratory distress syndrome
    • Hand IL, Shepard EK, Krauss AN, Auld PA. Discrepancies between transcutaneous and end-tidal carbon dioxide monitoring in the critically ill neonate with respiratory distress syndrome. Crit Care Med. 1989;17(6):556-559
    • (1989) Crit Care Med , vol.17 , Issue.6 , pp. 556-559
    • Hand, I.L.1    Shepard, E.K.2    Krauss, A.N.3    Auld, P.A.4
  • 15
    • 0026187760 scopus 로고
    • Technical and clinical aspects of capnography in neonates
    • Kirpalani H, Kechagias S, Lerman J. Technical and clinical aspects of capnography in neonates. J Med Eng Technol. 1991; 15(4-5):154-161
    • (1991) J Med Eng Technol , vol.15 , Issue.4-5 , pp. 154-161
    • Kirpalani, H.1    Kechagias, S.2    Lerman, J.3
  • 16
    • 0021881488 scopus 로고
    • Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects
    • Schieber RA, Namnoum A, Sugden A, Saville AL, Orr RA. Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects. J Clin Monit. 1985;1(3):149-155
    • (1985) J Clin Monit , vol.1 , Issue.3 , pp. 149-155
    • Schieber, R.A.1    Namnoum, A.2    Sugden, A.3    Saville, A.L.4    Orr, R.A.5
  • 17
    • 27644514527 scopus 로고    scopus 로고
    • Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport
    • Tingay DG, Stewart MJ, Morely CJ. Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport. Arch Dis Child Fetal Neonatal Ed. 2005;90(6): F523-F526
    • (2005) Arch Dis Child Fetal Neonatal Ed , vol.90 , Issue.6
    • Tingay, D.G.1    Stewart, M.J.2    Morely, C.J.3
  • 18
    • 0023525885 scopus 로고
    • 2 measurements sampled at the distal and proximal ends of the endotracheal tube in infants and children
    • 2 measurements sampled at the distal and proximal ends of the endotracheal tube in infants and children. Anesth Analg. 1987;66(10):959-964
    • (1987) Anesth Analg , vol.66 , Issue.10 , pp. 959-964
    • Badgwell, J.M.1    McLeod, M.E.2    Lerman, J.3    Creighton, R.E.4
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 0033238016 scopus 로고    scopus 로고
    • Microstream capnography technology: A new approach to an old problem
    • Colman Y, Krauss B. Microstream capnography technology: a new approach to an old problem. J Clin Monit Comput. 1999; 15(6):403-409
    • (1999) J Clin Monit Comput , vol.15 , Issue.6 , pp. 403-409
    • Colman, Y.1    Krauss, B.2
  • 24
    • 0025261219 scopus 로고
    • Transcutaneous carbon dioxide monitoring
    • Rennie JM. Transcutaneous carbon dioxide monitoring. Arch Dis Child. 1990;65(4 Spec No):345-346
    • (1990) Arch Dis Child , vol.65 , Issue.4 SPEC , pp. 345-346
    • Rennie, J.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.