메뉴 건너뛰기




Volumn 24, Issue 2, 2009, Pages 180-186

The Accuracy of Preoperative Templating in Cementless Total Hip Arthroplasty

Author keywords

accuracy; cementless total hip arthroplasty; clinical usefulness; preoperative templating

Indexed keywords

ACETABULUM; ARTHROPLASTY, REPLACEMENT, HIP; FEMALE; FEMUR; HIP DISLOCATION, CONGENITAL; HIP JOINT; HUMANS; MALE; MIDDLE AGED; OSTEOARTHRITIS; PREOPERATIVE CARE; PROSTHESIS FITTING; RANGE OF MOTION, ARTICULAR; REPRODUCIBILITY OF RESULTS; RETROSPECTIVE STUDIES;

EID: 58249086600     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2007.10.032     Document Type: Article
Times cited : (74)

References (37)
  • 1
    • 58249089133 scopus 로고    scopus 로고
    • Preoperative planning
    • Callaghan J.J., Rosenberg A.G., and Rubash H.E. (Eds), Lippincott Williams & Wilkins Company, Philadelphia (Pa)
    • Barrack R.L., and Burnett S.J. Preoperative planning. In: Callaghan J.J., Rosenberg A.G., and Rubash H.E. (Eds). The adult hip. 2nd ed. (2007), Lippincott Williams & Wilkins Company, Philadelphia (Pa) 884
    • (2007) The adult hip. 2nd ed. , pp. 884
    • Barrack, R.L.1    Burnett, S.J.2
  • 2
    • 0014848821 scopus 로고
    • total hip arthroplasty by low friction arthroplasty
    • Charnley J. total hip arthroplasty by low friction arthroplasty. Clin Orthop Relat Res 72 (1970) 7
    • (1970) Clin Orthop Relat Res , vol.72 , pp. 7
    • Charnley, J.1
  • 3
    • 58249084435 scopus 로고    scopus 로고
    • Primary total hip arthroplasty: preoperative planning and templating
    • Lieberman J.R., and Berry D.J. (Eds), American Academy of Orthopaedic Surgeons, Rosemont (Ill)
    • Garvin K.L. Primary total hip arthroplasty: preoperative planning and templating. In: Lieberman J.R., and Berry D.J. (Eds). Advanced reconstruction hip (2005), American Academy of Orthopaedic Surgeons, Rosemont (Ill) 41
    • (2005) Advanced reconstruction hip , pp. 41
    • Garvin, K.L.1
  • 4
    • 0029026133 scopus 로고
    • Determination of accuracy of preoperative templating of noncemented femoral prostheses
    • Carter L.W., Stovall D.O., and Young T.R. Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 10 (1995) 507
    • (1995) J Arthroplasty , vol.10 , pp. 507
    • Carter, L.W.1    Stovall, D.O.2    Young, T.R.3
  • 5
    • 0031972218 scopus 로고    scopus 로고
    • The value of preoperative planning for total hip arthroplasty
    • Eggli S., Pisan M., and Muller M.E. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg (Br) 80 (1998) 382
    • (1998) J Bone Joint Surg (Br) , vol.80 , pp. 382
    • Eggli, S.1    Pisan, M.2    Muller, M.E.3
  • 6
    • 12344287883 scopus 로고    scopus 로고
    • The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty
    • Gonzalez Della Valle A., Slullitel G., Piccaluga F., et al. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20 (2005) 51
    • (2005) J Arthroplasty , vol.20 , pp. 51
    • Gonzalez Della Valle, A.1    Slullitel, G.2    Piccaluga, F.3
  • 7
    • 0026878094 scopus 로고
    • Preoperative templating for the equalization of leg lengths in total hip arthroplasty
    • Goodman S.B., Huene D.S., and Imrie S. Preoperative templating for the equalization of leg lengths in total hip arthroplasty. Contemp Orthop 24 (1992) 703
    • (1992) Contemp Orthop , vol.24 , pp. 703
    • Goodman, S.B.1    Huene, D.S.2    Imrie, S.3
  • 8
    • 0026438998 scopus 로고
    • Preoperative planning for total hip arthroplasty: quantitating its utility and precision
    • Knight J.L., and Atwater R.D. Preoperative planning for total hip arthroplasty: quantitating its utility and precision. J Arthroplasty 7 suppl (1992) 403
    • (1992) J Arthroplasty , vol.7 , Issue.SUPPL , pp. 403
    • Knight, J.L.1    Atwater, R.D.2
  • 9
    • 0642297682 scopus 로고
    • Total hip reconstruction
    • Evarts C.M. (Ed), Churchill Living Stone, New York, NY
    • Muller M.E. Total hip reconstruction. In: Evarts C.M. (Ed). Surgery of the musculoskeletal system (1983), Churchill Living Stone, New York, NY 223
    • (1983) Surgery of the musculoskeletal system , pp. 223
    • Muller, M.E.1
  • 10
    • 0017041228 scopus 로고
    • Improved methods for quantitative radiographic evaluation with particular reference to total hip arthroplasty
    • Clarke I.C., Gruen T., Matos M., et al. Improved methods for quantitative radiographic evaluation with particular reference to total hip arthroplasty. Clin Orthop Relat Res 121 (1976) 83
    • (1976) Clin Orthop Relat Res , vol.121 , pp. 83
    • Clarke, I.C.1    Gruen, T.2    Matos, M.3
  • 13
    • 0023715488 scopus 로고
    • The acetabular teardrop and its relevance to acetabular migration
    • Goodman S.B., Adler S.J., Fyhrie D.P., et al. The acetabular teardrop and its relevance to acetabular migration. Clin Orthop Relat Res 236 (1988) 199
    • (1988) Clin Orthop Relat Res , vol.236 , pp. 199
    • Goodman, S.B.1    Adler, S.J.2    Fyhrie, D.P.3
  • 14
    • 0029114941 scopus 로고
    • Measurement of acetabular version on the axiolateral radiograph
    • Yao L., Yao J., and Gold R.H. Measurement of acetabular version on the axiolateral radiograph. Clin Orthop Relat Res 316 (1995) 106
    • (1995) Clin Orthop Relat Res , vol.316 , pp. 106
    • Yao, L.1    Yao, J.2    Gold, R.H.3
  • 15
    • 5344276587 scopus 로고    scopus 로고
    • Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years
    • Berend K.R., Lombardi Jr. A.V., Mallory T.H., et al. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years. J Arthroplasty 19 suppl (2004) 17
    • (2004) J Arthroplasty , vol.19 , Issue.SUPPL , pp. 17
    • Berend, K.R.1    Lombardi Jr., A.V.2    Mallory, T.H.3
  • 16
    • 0036084025 scopus 로고    scopus 로고
    • Management of periprosthetic fractures: the hip
    • Berry D.J. Management of periprosthetic fractures: the hip. J Arthroplasty 17 suppl (2002) 11
    • (2002) J Arthroplasty , vol.17 , Issue.SUPPL , pp. 11
    • Berry, D.J.1
  • 17
    • 0031704870 scopus 로고    scopus 로고
    • Periprosthetic fractures associated with total hip arthroplasty
    • Kyle R.F., and Crickard III G.E. Periprosthetic fractures associated with total hip arthroplasty. Orthopedics 21 (1998) 982
    • (1998) Orthopedics , vol.21 , pp. 982
    • Kyle, R.F.1    Crickard III, G.E.2
  • 18
    • 30344448619 scopus 로고    scopus 로고
    • Risk factors for intraoperative femoral fractures during total hip arthroplasty
    • Moroni A., Faldini C., Piras F., et al. Risk factors for intraoperative femoral fractures during total hip arthroplasty. Ann Chir Gynaecol 89 (2000) 113
    • (2000) Ann Chir Gynaecol , vol.89 , pp. 113
    • Moroni, A.1    Faldini, C.2    Piras, F.3
  • 19
    • 0031228973 scopus 로고    scopus 로고
    • Periprosthetic fractures: early and late
    • Reis M.D. Periprosthetic fractures: early and late. Orthopedics 20 (1997) 789
    • (1997) Orthopedics , vol.20 , pp. 789
    • Reis, M.D.1
  • 20
    • 0036193465 scopus 로고    scopus 로고
    • Periprosthetic fractures of the femur
    • Schmidt A.H., and Kyle R.F. Periprosthetic fractures of the femur. Orthop Clin North Am 33 (2002) 143
    • (2002) Orthop Clin North Am , vol.33 , pp. 143
    • Schmidt, A.H.1    Kyle, R.F.2
  • 21
    • 0021968348 scopus 로고
    • Late dislocations in patients with Charnley total hip arthroplasty
    • Coventry M.B. Late dislocations in patients with Charnley total hip arthroplasty. J Bone Joint Surg 67 (1985) 832
    • (1985) J Bone Joint Surg , vol.67 , pp. 832
    • Coventry, M.B.1
  • 22
    • 0034012520 scopus 로고    scopus 로고
    • The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head neck ratios
    • D'Lima D.D., Urquhart A.G., Buehler K.O., et al. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head neck ratios. J Bone Joint Surg 82 (2000) 315
    • (2000) J Bone Joint Surg , vol.82 , pp. 315
    • D'Lima, D.D.1    Urquhart, A.G.2    Buehler, K.O.3
  • 23
    • 0034955762 scopus 로고    scopus 로고
    • Effect of acetabular cup position and orientation in cemented total hip arthroplasty
    • Hirakawa K., Mitsugi N., Koshino T., et al. Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res 388 (2001) 135
    • (2001) Clin Orthop Relat Res , vol.388 , pp. 135
    • Hirakawa, K.1    Mitsugi, N.2    Koshino, T.3
  • 24
    • 0032801048 scopus 로고    scopus 로고
    • The effect of acetabular cup orientations on limiting hip rotation
    • Kummer F.J., Shah S., Iyer S., et al. The effect of acetabular cup orientations on limiting hip rotation. J Arthroplasty 14 (1999) 509
    • (1999) J Arthroplasty , vol.14 , pp. 509
    • Kummer, F.J.1    Shah, S.2    Iyer, S.3
  • 25
    • 0017859205 scopus 로고
    • Dislocations after total hip arthroplasty arthroplasties
    • Lewinnek G.E., Lewis J.L., Tarr R., et al. Dislocations after total hip arthroplasty arthroplasties. J Bone Joint Surg 60 (1978) 217
    • (1978) J Bone Joint Surg , vol.60 , pp. 217
    • Lewinnek, G.E.1    Lewis, J.L.2    Tarr, R.3
  • 26
    • 0038686674 scopus 로고    scopus 로고
    • Image-based hip navigation
    • Wentzensen A., Zheng G., Vock B., et al. Image-based hip navigation. Int Orthop 27 suppl (2003) 43
    • (2003) Int Orthop , vol.27 , Issue.SUPPL , pp. 43
    • Wentzensen, A.1    Zheng, G.2    Vock, B.3
  • 27
    • 0037822087 scopus 로고    scopus 로고
    • Dislocation after total hip arthroplasty: implant design and orientation
    • Barrack R.L. Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg 11 (2003) 89
    • (2003) J Am Acad Orthop Surg , vol.11 , pp. 89
    • Barrack, R.L.1
  • 28
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migration
    • Kennedy J.G., Rogers W.B., Soffe K.E., et al. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migration. J Arthroplasty 13 (1998) 530
    • (1998) J Arthroplasty , vol.13 , pp. 530
    • Kennedy, J.G.1    Rogers, W.B.2    Soffe, K.E.3
  • 29
    • 0026522003 scopus 로고
    • Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty
    • Mian S.W., Truchly G., and Pflum F.A. Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty. Clin Orthop Relat Res 276 (1992) 206
    • (1992) Clin Orthop Relat Res , vol.276 , pp. 206
    • Mian, S.W.1    Truchly, G.2    Pflum, F.A.3
  • 30
    • 1242319991 scopus 로고    scopus 로고
    • Influence of component positions on dislocation: computed tomographic evaluations in a consecutive series of total hip arthroplasty
    • Nishii T., Sugano N., Miki H., et al. Influence of component positions on dislocation: computed tomographic evaluations in a consecutive series of total hip arthroplasty. J Arthroplasty 19 (2004) 162
    • (2004) J Arthroplasty , vol.19 , pp. 162
    • Nishii, T.1    Sugano, N.2    Miki, H.3
  • 31
    • 33646842696 scopus 로고    scopus 로고
    • Acetabular component orientation in 834 total hip arthroplasties using a manual technique
    • Minoda Y., Kadowaki T., and Kim M. Acetabular component orientation in 834 total hip arthroplasties using a manual technique. Clin Orthop Relat Res 445 (2006) 186
    • (2006) Clin Orthop Relat Res , vol.445 , pp. 186
    • Minoda, Y.1    Kadowaki, T.2    Kim, M.3
  • 32
    • 33646824530 scopus 로고    scopus 로고
    • Factors influencing cup orientation in 500 consecutive total hip arthroplasties
    • Rittmeister M., and Callitsis C. Factors influencing cup orientation in 500 consecutive total hip arthroplasties. Clin Orthop Relat Res 445 (2006) 192
    • (2006) Clin Orthop Relat Res , vol.445 , pp. 192
    • Rittmeister, M.1    Callitsis, C.2
  • 33
    • 0021057875 scopus 로고
    • Clinical symptoms and biomechanics of lumbar spine and hip joint in leg length inequality
    • Friberg O. Clinical symptoms and biomechanics of lumbar spine and hip joint in leg length inequality. Spine 8 (1983) 643
    • (1983) Spine , vol.8 , pp. 643
    • Friberg, O.1
  • 34
    • 0019809314 scopus 로고
    • Low-back pain associated with leg length inequality
    • Giles L.G., and Taylor J.R. Low-back pain associated with leg length inequality. Spine 6 (1981) 510
    • (1981) Spine , vol.6 , pp. 510
    • Giles, L.G.1    Taylor, J.R.2
  • 35
    • 2942597628 scopus 로고    scopus 로고
    • Leg length discrepancy after total hip arthroplasty
    • Maloney W.J., and Keeney J.A. Leg length discrepancy after total hip arthroplasty. J Arthroplasty 19 suppl (2004) 108
    • (2004) J Arthroplasty , vol.19 , Issue.SUPPL , pp. 108
    • Maloney, W.J.1    Keeney, J.A.2
  • 36
    • 0026558401 scopus 로고
    • Walking ability after total hip arthroplasty: a comparison of gait analysis in unilateral and bilateral cases
    • Wykman A., and Olsson E. Walking ability after total hip arthroplasty: a comparison of gait analysis in unilateral and bilateral cases. J Bone Joint Surg (Br) 74 (1992) 53
    • (1992) J Bone Joint Surg (Br) , vol.74 , pp. 53
    • Wykman, A.1    Olsson, E.2
  • 37
    • 0032972743 scopus 로고    scopus 로고
    • Results of a method of leg-length equalization for patients undergoing primary total hip arthroplasty
    • Woolson S.T., Hartford J.M., and Sawyer A. Results of a method of leg-length equalization for patients undergoing primary total hip arthroplasty. J Arthroplasty 14 (1999) 159
    • (1999) J Arthroplasty , vol.14 , pp. 159
    • Woolson, S.T.1    Hartford, J.M.2    Sawyer, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.