메뉴 건너뛰기




Volumn 2, Issue 4, 2008, Pages

Design modifications and optimization of a commercially available knee simulator

Author keywords

Knee simulator; Load distribution; PE wear; Wear scar

Indexed keywords

COMPONENT DESIGNS; COMPUTER-AIDED DESIGNS; DESIGN MODIFICATIONS; ENDOPROSTHESES; GAIN INFORMATIONS; ISO STANDARDS; KNEE SIMULATOR; LOAD DISTRIBUTION; MECHANICAL FAILURES; PE WEAR; WEAR BEHAVIORS; WEAR DEBRIS; WEAR SCAR; WEAR TESTS;

EID: 58149489314     PISSN: 19326181     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.2979746     Document Type: Article
Times cited : (3)

References (22)
  • 1
    • 0033628937 scopus 로고    scopus 로고
    • Biological Reactions to Wear Debris in Total Joint Replacement
    • Ingham, E., and Fisher, J., 2000, "Biological Reactions to Wear Debris in Total Joint Replacement," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 214(1), pp. 21-37.
    • (2000) Proc. Inst. Mech. Eng., Part H: J. Eng. Med , vol.214 , Issue.1 , pp. 21-37
    • Ingham, E.1    Fisher, J.2
  • 3
    • 58149499967 scopus 로고    scopus 로고
    • EN 12564 Standard, 1998, Non-Active Surgical Implants - Joint Replacement Implants - Specific Requirements for Knee Joint Replacement Implants.
    • EN 12564 Standard, 1998, "Non-Active Surgical Implants - Joint Replacement Implants - Specific Requirements for Knee Joint Replacement Implants."
  • 4
  • 5
    • 0026848920 scopus 로고
    • Three-Dimensional Kinematics of the Human Knee During Walking
    • Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., and Kalenak, A., 1992, "Three-Dimensional Kinematics of the Human Knee During Walking," J. Biomech. 25(4), pp. 347-357.
    • (1992) J. Biomech , vol.25 , Issue.4 , pp. 347-357
    • Lafortune, M.A.1    Cavanagh, P.R.2    Sommer, H.J.3    Kalenak, A.4
  • 6
    • 0014698584 scopus 로고
    • The Mechanics of the Knee Joint in Relation to Normal Walking
    • Morrison, J. B., 1970, "The Mechanics of the Knee Joint in Relation to Normal Walking," J. Biomech. 3(1), pp. 51-61.
    • (1970) J. Biomech , vol.3 , Issue.1 , pp. 51-61
    • Morrison, J.B.1
  • 7
    • 10444259142 scopus 로고    scopus 로고
    • Implants for Surgery - Wear of Total Knee-Joint Prostheses - Part 1: Loading and Displacement Parameters for Wear-Testing Machines With Load Control and Corresponding Environmental Conditions for Test
    • ISO 14243-1
    • ISO 14243-1, 2002, "Implants for Surgery - Wear of Total Knee-Joint Prostheses - Part 1: Loading and Displacement Parameters for Wear-Testing Machines With Load Control and Corresponding Environmental Conditions for Test."
    • (2002)
  • 8
    • 20444486306 scopus 로고    scopus 로고
    • Implants for Surgery - Wear of Total Knee-Joint Prostheses - Part 3: Loading and Displacement Parameters for Wear-Testing Machines With Displacement Control and Corresponding Environmental Conditions for Test
    • ISO 14243-3
    • ISO 14243-3, 2004, "Implants for Surgery - Wear of Total Knee-Joint Prostheses - Part 3: Loading and Displacement Parameters for Wear-Testing Machines With Displacement Control and Corresponding Environmental Conditions for Test."
    • (2004)
  • 10
    • 0020065872 scopus 로고    scopus 로고
    • Fukubayashi, T., Torzilli, P. A., Sherman, M. E, and Warren, R. F., 1982, An In Vitro Biomechanical Evaluation of Anterior-Posterior Motion of the Knee. Tibial Displacement, Rotation, and Torque, J. Bone Jt. Surg., Am. 64(2), pp. 258-264.
    • Fukubayashi, T., Torzilli, P. A., Sherman, M. E, and Warren, R. F., 1982, "An In Vitro Biomechanical Evaluation of Anterior-Posterior Motion of the Knee. Tibial Displacement, Rotation, and Torque," J. Bone Jt. Surg., Am. Vol., Vol. 64(2), pp. 258-264.
  • 11
    • 0035175965 scopus 로고    scopus 로고
    • Wear Performance of Ultra-High Molecular Weight Polyethylene on Oxidized Zirconium Total Knee Femoral Components
    • Spector, B. M., Ries, M. D., Bourne, R. B., Sauer, W. S., Long, M., and Hunter, G., 2001, "Wear Performance of Ultra-High Molecular Weight Polyethylene on Oxidized Zirconium Total Knee Femoral Components," J. Bone Jt. Surg., Am. Vol. 83-A, pp. 80-86.
    • (2001) J. Bone Jt. Surg., Am , vol.83-A , pp. 80-86
    • Spector, B.M.1    Ries, M.D.2    Bourne, R.B.3    Sauer, W.S.4    Long, M.5    Hunter, G.6
  • 12
    • 0033627424 scopus 로고    scopus 로고
    • Wear Testing of UHMWPE Tibial Components: Influence of Oxidation
    • Young, S. K., Keller, T. S., Greer, K. W., and Gorhan, M. C., 2000, "Wear Testing of UHMWPE Tibial Components: Influence of Oxidation," ASME J. Tribol., 122, pp. 323-331.
    • (2000) ASME J. Tribol , vol.122 , pp. 323-331
    • Young, S.K.1    Keller, T.S.2    Greer, K.W.3    Gorhan, M.C.4
  • 14
    • 0018859548 scopus 로고
    • The Distribution of Load Across the Knee. A Comparison of Static and Dynamic Measurements
    • Johnson, F., Leitl, S., and Waugh, W., 1980, "The Distribution of Load Across the Knee. A Comparison of Static and Dynamic Measurements," J. Bone Joint Surg. Br. 62(3), pp. 346-349.
    • (1980) J. Bone Joint Surg. Br , vol.62 , Issue.3 , pp. 346-349
    • Johnson, F.1    Leitl, S.2    Waugh, W.3
  • 15
    • 0020694705 scopus 로고    scopus 로고
    • Harrington, I. J., 1983, Static and Dynamic Loading Patterns in Knee Joints With Deformities, J. Bone Jt. Surg., Am. 65(2), pp. 247-259.
    • Harrington, I. J., 1983, "Static and Dynamic Loading Patterns in Knee Joints With Deformities," J. Bone Jt. Surg., Am. Vol., Vol. 65(2), pp. 247-259.
  • 17
    • 0023024581 scopus 로고
    • Knee Biomechanics and Total Knee Replacement
    • Andriacchi, T. P., Stanwyck, T. S., and Galante, J. O., 1986, "Knee Biomechanics and Total Knee Replacement," J. Arthroplasty 1(3), pp. 211-219.
    • (1986) J. Arthroplasty , vol.1 , Issue.3 , pp. 211-219
    • Andriacchi, T.P.1    Stanwyck, T.S.2    Galante, J.O.3
  • 18
    • 0038066781 scopus 로고    scopus 로고
    • An Analysis of Rotating-Platform Total Knee Replacements
    • Bourne, R. B., Masonis, J., and Anthony, M., 2003, "An Analysis of Rotating-Platform Total Knee Replacements," Clin. Orthop. Relat. Res. 410, pp. 173-180.
    • (2003) Clin. Orthop. Relat. Res , vol.410 , pp. 173-180
    • Bourne, R.B.1    Masonis, J.2    Anthony, M.3
  • 21
    • 58149509837 scopus 로고    scopus 로고
    • VDI 2222:06-1997: Methodical Development of Solution Principles, VDI Guidelines, Düsseldorf, Germany.
    • VDI 2222:06-1997: Methodical Development of Solution Principles, VDI Guidelines, Düsseldorf, Germany.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.