메뉴 건너뛰기




Volumn 8, Issue 1, 2009, Pages 70-73

High-dose-rate prostate brachytherapy in a patient with bilateral hip prostheses planned using megavoltage computed tomography images acquired with a helical tomotherapy unit

Author keywords

Helical tomotherapy; High dose rate brachytherapy; Hip prostheses; MVCT; Prostate

Indexed keywords

ANDROGEN;

EID: 58149483697     PISSN: 15384721     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.brachy.2008.08.011     Document Type: Article
Times cited : (10)

References (11)
  • 1
    • 21244471813 scopus 로고    scopus 로고
    • An adaptive approach to metal artifact reduction in helical computed tomography for radiation treatment planning: Experimental and clinical studies
    • Yazida M., Gingras L., and Beaulieu L. An adaptive approach to metal artifact reduction in helical computed tomography for radiation treatment planning: Experimental and clinical studies. Int J Radiat Oncol Biol Phys 62 (2005) 1224-1231
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 1224-1231
    • Yazida, M.1    Gingras, L.2    Beaulieu, L.3
  • 2
    • 10744226022 scopus 로고    scopus 로고
    • Dosimetric considerations for patients with hip prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63
    • Reft C., Alecu R., Das I.J., et al. Dosimetric considerations for patients with hip prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63. Med Phys 30 (2003) 1162-1182
    • (2003) Med Phys , vol.30 , pp. 1162-1182
    • Reft, C.1    Alecu, R.2    Das, I.J.3
  • 3
    • 33748313414 scopus 로고    scopus 로고
    • The use of megavoltage cone-beam Ct to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement
    • Aubin M., Morin O., Chen J., et al. The use of megavoltage cone-beam Ct to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement. Br J Radiol 79 (2006) 918-921
    • (2006) Br J Radiol , vol.79 , pp. 918-921
    • Aubin, M.1    Morin, O.2    Chen, J.3
  • 4
    • 0035160344 scopus 로고    scopus 로고
    • Phase II prospective study of the use of conformal high-dose-rate brachytherapy as monotherapy for the treatment of favorable stage prostate cancer: A feasibility report
    • Martinez A.A., Pataki I., Edmundson G., et al. Phase II prospective study of the use of conformal high-dose-rate brachytherapy as monotherapy for the treatment of favorable stage prostate cancer: A feasibility report. Int J Radiat Oncol Biol Phys 49 (2001) 61-69
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 61-69
    • Martinez, A.A.1    Pataki, I.2    Edmundson, G.3
  • 5
    • 58149529321 scopus 로고    scopus 로고
    • HDR vs. LDR (Pd103 permanent implants) brachytherapy as monotherapy for prostate cancer. Timing to onset and predictors of erectile dysfunction
    • Ghilezan M., Vargas C., Gustafson G., et al. HDR vs. LDR (Pd103 permanent implants) brachytherapy as monotherapy for prostate cancer. Timing to onset and predictors of erectile dysfunction. Int J Radiat Oncol Biol Phys 60 (2004) S442
    • (2004) Int J Radiat Oncol Biol Phys , vol.60
    • Ghilezan, M.1    Vargas, C.2    Gustafson, G.3
  • 6
    • 58149513508 scopus 로고    scopus 로고
    • Similar 5-year clinical outcome for high dose rate (HDR) and low dose rate (LDR) brachytherapy (BT) for early prostate cancer patients
    • Ghilezan M., Vargas C., Gustafson G., et al. Similar 5-year clinical outcome for high dose rate (HDR) and low dose rate (LDR) brachytherapy (BT) for early prostate cancer patients. Int J Radiat Oncol Biol Phys 63 (2005) S37
    • (2005) Int J Radiat Oncol Biol Phys , vol.63
    • Ghilezan, M.1    Vargas, C.2    Gustafson, G.3
  • 7
    • 0034559749 scopus 로고    scopus 로고
    • High dose rate prostate brachytherapy: The California Endocurietherapy (CET) method
    • Demanes D.J., Rodriguez R.R., and Altieri G.A. High dose rate prostate brachytherapy: The California Endocurietherapy (CET) method. Radiother Oncol 57 (2000) 289-296
    • (2000) Radiother Oncol , vol.57 , pp. 289-296
    • Demanes, D.J.1    Rodriguez, R.R.2    Altieri, G.A.3
  • 8
    • 16344388273 scopus 로고    scopus 로고
    • High-dose-rate intensity-modulated brachytherapy with external beam radiotherapy for prostate cancer: California Endocurietherapy's 10-year results
    • Demanes D.J., Rodriguez R.R., Schour L., et al. High-dose-rate intensity-modulated brachytherapy with external beam radiotherapy for prostate cancer: California Endocurietherapy's 10-year results. Int J Radiat Oncol Biol Phys 61 (2005) 1306-1316
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1306-1316
    • Demanes, D.J.1    Rodriguez, R.R.2    Schour, L.3
  • 9
    • 58149494759 scopus 로고    scopus 로고
    • Aubin M, Morin O, Bucci K, et al. Megavoltage conebeam CT to complement prostate planning CT in presence of hip prosthesis. ESTRO Annual Meeting (abstract), Lisbon, 2005.
    • Aubin M, Morin O, Bucci K, et al. Megavoltage conebeam CT to complement prostate planning CT in presence of hip prosthesis. ESTRO Annual Meeting (abstract), Lisbon, 2005.
  • 10
    • 58149510694 scopus 로고    scopus 로고
    • MVCT versus kVCT images for radiotherapy planning in prostate cancer patients with hip prosthesis
    • Quon H., Saski D., Lian J., et al. MVCT versus kVCT images for radiotherapy planning in prostate cancer patients with hip prosthesis. Radiother Oncol 80 (2006) S31-S32
    • (2006) Radiother Oncol , vol.80
    • Quon, H.1    Saski, D.2    Lian, J.3
  • 11
    • 37349102674 scopus 로고    scopus 로고
    • Megavoltage computed tomography: An emerging tool for image-guided radiotherapy
    • Hong T.S., Welsh J.S., Ritter M.A., et al. Megavoltage computed tomography: An emerging tool for image-guided radiotherapy. Am J Clin Oncol 30 (2007) 617-623
    • (2007) Am J Clin Oncol , vol.30 , pp. 617-623
    • Hong, T.S.1    Welsh, J.S.2    Ritter, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.