메뉴 건너뛰기




Volumn 28, Issue 4, 2008, Pages 267-273

Evaluation of iQ200 automated urine microscopy analyzer

Author keywords

Automated urinalysis; IQ200; Urine sediment

Indexed keywords

ARTICLE; AUTOANALYSIS; CYTOLOGY; EVALUATION; HUMAN; INSTRUMENTATION; METHODOLOGY; MICROBIOLOGY; QUALITY CONTROL; SENSITIVITY AND SPECIFICITY; URINALYSIS; URINE;

EID: 58149346107     PISSN: 15986535     EISSN: None     Source Type: Journal    
DOI: 10.3343/kjlm.2008.28.4.267     Document Type: Article
Times cited : (14)

References (18)
  • 2
    • 0005275835 scopus 로고
    • Comparison and standardization of the urine microscopic examination
    • Ferris JA. Comparison and standardization of the urine microscopic examination. Lab Med 1983;14:659-62.
    • (1983) Lab Med , vol.14 , pp. 659-662
    • Ferris, J.A.1
  • 3
    • 2342501742 scopus 로고    scopus 로고
    • The (fixed) urinary sediment, a simple and useful diagnostic tool in patients with haematuria
    • Huussen J, Koene RA, Hilbrands LB. The (fixed) urinary sediment, a simple and useful diagnostic tool in patients with haematuria. Neth J Med 2004;62:4-9. (Pubitemid 39089448)
    • (2004) Netherlands Journal of Medicine , vol.62 , Issue.1 , pp. 4-9
    • Huussen, J.1    Koene, R.A.P.2    Hilbrands, L.B.3
  • 6
    • 13244265665 scopus 로고    scopus 로고
    • Analytic performance of the iQ200 automated urine microscopy analyzer and comparison with manual counts using Fuchs-Rosenthal cell chambers
    • DOI 10.1309/VNGU-9Q5V-932D-74NU
    • Wah DT, Wises PK, Butch AW. Analytic performance of the iQ200 automated urine microscopy analyzer and comparison with manual counts using Fuchs-Rosenthal cell chambers. Am J Clin Pathol 2005;123:290-6. (Pubitemid 40194093)
    • (2005) American Journal of Clinical Pathology , vol.123 , Issue.2 , pp. 290-296
    • Wah, D.T.1    Wises, P.K.2    Butch, A.W.3
  • 8
    • 34547838282 scopus 로고    scopus 로고
    • Urine sediment examination: A comparison of automated urinalysis systems and manual microscopy
    • Chien TI, Kao JT, Liu HL, Lin PC, Hong JS, Hsieh HP, et al. Urine sediment examination: a comparison of automated urinalysis systems and manual microscopy. Clin Chim Acta 2007;384:28-34.
    • (2007) Clin Chim Acta , vol.384 , pp. 28-34
    • Chien, T.I.1    Kao, J.T.2    Liu, H.L.3    Lin, P.C.4    Hong, J.S.5    Hsieh, H.P.6
  • 9
    • 34548565908 scopus 로고    scopus 로고
    • Automated urinalysis: First experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting
    • DOI 10.1515/CCLM.2007.503
    • Shayanfar N, Tobler U, von Eckardstein A, Bestmann L. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting. Clin Chem Lab Med 2007;45:1251-6. (Pubitemid 47396260)
    • (2007) Clinical Chemistry and Laboratory Medicine , vol.45 , Issue.9 , pp. 1251-1256
    • Shayanfar, N.1    Tobler, U.2    Von Eckardstein, A.3    Bestmann, L.4
  • 12
    • 0003547060 scopus 로고    scopus 로고
    • National Committee for Clinical Laboratory Standards. NCCLS document EP5-A. Wayne, PA: National Committee for Clinical Laboratory Standards
    • National Committee for Clinical Laboratory Standards. Evaluation of the precision performance of clinical chemistry devices; approved guideline. NCCLS document EP5-A. Wayne, PA: National Committee for Clinical Laboratory Standards, 1999.
    • (1999) Evaluation of the Precision Performance of Clinical Chemistry Devices; Approved Guideline
  • 13
    • 80055113170 scopus 로고    scopus 로고
    • Laboratory automation
    • Kaplan LA, Pesce AJ, et al. eds. 4th ed. Baltimore: Mosby
    • Pesce MA. Laboratory automation. In: Kaplan LA, Pesce AJ, et al. eds. Clinical Chemistry. 4th ed. Baltimore: Mosby, 2003;294.
    • (2003) Clinical Chemistry , pp. 294
    • Pesce, M.A.1
  • 14
    • 0037380114 scopus 로고    scopus 로고
    • Quantitative urine particle analysis: Integrative approach for the optimal combination of automation with UF-100 and microscopic review with KOVA cell chamber
    • DOI 10.1373/49.4.617
    • Ottiger C and Huber AR. Quantitative urine particle analysis: integrative approach for the optimal combination of automation with UF-100 and microscopic review with KOVA cell chamber. Clin Chem 2003;49:617-23. (Pubitemid 36379528)
    • (2003) Clinical Chemistry , vol.49 , Issue.4 , pp. 617-623
    • Ottiger, C.1    Huber, A.R.2
  • 16
    • 0022271440 scopus 로고
    • 'The Yellow IRIS(TM)' urinalysis workstation - The first commercial application of automated intelligent microscopy
    • Deindoerfer FH, Gangwer JR, Laird CW, Ringold RR. "The Yellow IRIS" urinalysis workstation-the first commercial application of "automated intelligent microscopy". Clin Chem 1985;31:1491-9. (Pubitemid 16011837)
    • (1985) Clinical Chemistry , vol.31 , Issue.9 , pp. 1491-1499
    • Deindoerfer, F.H.1    Gangwer, J.R.2    Laird, C.W.3    Ringold, R.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.