메뉴 건너뛰기




Volumn 20, Issue 1, 2009, Pages 33-36

Intraocular lens centration and stability: efficacy of current technique and technology

Author keywords

Anterior segment optical coherence tomography; Photography analysis retroillumination images; Scheimpflug imaging

Indexed keywords

IMAGE ANALYSIS; IMAGING; LENS IMPLANT; LENS IMPLANTATION; OPTICAL COHERENCE TOMOGRAPHY; PHOTOGRAPHY; PRIORITY JOURNAL; REVIEW;

EID: 58149269069     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICU.0b013e328318591c     Document Type: Review
Times cited : (15)

References (23)
  • 1
    • 0025775401 scopus 로고
    • Design of aspheric intraocular lenses
    • Atchison DA. Design of aspheric intraocular lenses. Ophthalmic Physiol Opt 1991; 11:137-146.
    • (1991) Ophthalmic Physiol Opt , vol.11 , pp. 137-146
    • Atchison, D.A.1
  • 2
    • 16344378592 scopus 로고    scopus 로고
    • Optical performance of 3 intraocular lens designs in the presence of decentration
    • Altmann GE, Nichamin LD, Lane SS, Pepose JS. Optical performance of 3 intraocular lens designs in the presence of decentration. J Cataract Refract Surg 2005;31:574-585.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 574-585
    • Altmann, G.E.1    Nichamin, L.D.2    Lane, S.S.3    Pepose, J.S.4
  • 3
    • 0036859744 scopus 로고    scopus 로고
    • A new intraocular lens design to reduce spherical aberration of pseudophakic eyes
    • Holladay JT, Piers PA, Koranyi G, et al. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. J Refract Surg 2002; 18:683-691.
    • (2002) J Refract Surg , vol.18 , pp. 683-691
    • Holladay, J.T.1    Piers, P.A.2    Koranyi, G.3
  • 4
    • 25144506466 scopus 로고    scopus 로고
    • Limitations of correcting spherical aberration with aspheric intraocular lenses
    • Diezte KK, Cox MJ. Limitations of correcting spherical aberration with aspheric intraocular lenses. J Refract Surg 2005; 21:S541 -S546.
    • (2005) J Refract Surg , vol.21
    • Diezte, K.K.1    Cox, M.J.2
  • 5
    • 0033510540 scopus 로고    scopus 로고
    • Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part l: Elimination of fixation-induced decentration to achieve precise optical correction and visual rehabilitation
    • Ram J, Apple DJ, Peng Q, et al Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part l: elimination of fixation-induced decentration to achieve precise optical correction and visual rehabilitation. Ophthalmology 1999; 106:883-890.
    • (1999) Ophthalmology , vol.106 , pp. 883-890
    • Ram, J.1    Apple, D.J.2    Peng, Q.3
  • 6
    • 0342748697 scopus 로고    scopus 로고
    • Decentration and tilt: Silicone multifocal versus acrylic soft intraocular lenses
    • Jung CK, Chung SK, Baek NH. Decentration and tilt: silicone multifocal versus acrylic soft intraocular lenses. J Cataract Refract Surg 2000; 26:582-585.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 582-585
    • Jung, C.K.1    Chung, S.K.2    Baek, N.H.3
  • 7
    • 0141458945 scopus 로고    scopus 로고
    • A clinical comparison of singlepiece and three-piece truncated hydrophobic acrylic intraocular lenses
    • Wallin TR, Hinckley M, Nilson C, Olson RJ. A clinical comparison of singlepiece and three-piece truncated hydrophobic acrylic intraocular lenses. Am J Ophthalmol 2003; 136:614-619.
    • (2003) Am J Ophthalmol , vol.136 , pp. 614-619
    • Wallin, T.R.1    Hinckley, M.2    Nilson, C.3    Olson, R.J.4
  • 8
    • 24944471397 scopus 로고    scopus 로고
    • Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye
    • Wang L, Koch DD. Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye. Arch Ophthalmol 2005; 123:1226-1230.
    • (2005) Arch Ophthalmol , vol.123 , pp. 1226-1230
    • Wang, L.1    Koch, D.D.2
  • 9
    • 34250635862 scopus 로고    scopus 로고
    • New intraocular lens for achromatizing the human eye
    • Lopez-Gil N, Montes-Mico R. New intraocular lens for achromatizing the human eye. J Cataract Refract Surg 2007; 33:1296-1302.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1296-1302
    • Lopez-Gil, N.1    Montes-Mico, R.2
  • 10
    • 0029385260 scopus 로고
    • Statistical distribution of foveal transverse chromatic aberration, pupil centration, and angle psi in a population of young adult eyes
    • Rynders M, Lidkea B, Chisholm W, Thibos LN. Statistical distribution of foveal transverse chromatic aberration, pupil centration, and angle psi in a population of young adult eyes. J Opt Soc Am A Opt Image Sci Vis 1995; 12:2348-2357.
    • (1995) J Opt Soc Am A Opt Image Sci Vis , vol.12 , pp. 2348-2357
    • Rynders, M.1    Lidkea, B.2    Chisholm, W.3    Thibos, L.N.4
  • 11
    • 58149271923 scopus 로고    scopus 로고
    • •• Montes-Mico R, Ferrer-Blasco T, Cervino A. Is there a benefit to aspheric intraocular lenses? A review of the literature. J Cataract Refract Surg (in press). This study shows a full review of visual and optical quality outcomes found in different articles in which aspheric IOLs were implanted.
    • •• Montes-Mico R, Ferrer-Blasco T, Cervino A. Is there a benefit to aspheric intraocular lenses? A review of the literature. J Cataract Refract Surg (in press). This study shows a full review of visual and optical quality outcomes found in different articles in which aspheric IOLs were implanted.
  • 12
    • 16344393329 scopus 로고    scopus 로고
    • Evaluating the eye's rotational stability during standard photography: Effect on determining the axial orientation of toric intraocular lenses
    • Viestenz A, Seitz B, Langenbucher A. Evaluating the eye's rotational stability during standard photography: effect on determining the axial orientation of toric intraocular lenses. J Cataract Refract Surg 2005; 31:557-561.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 557-561
    • Viestenz, A.1    Seitz, B.2    Langenbucher, A.3
  • 13
    • 40949125167 scopus 로고    scopus 로고
    • • Mendicute J, Irigoyen C, Aramberri J, et al. Foldable toric intraocular lens for astigmatism correction in cataract patients. J Cataract Refract Surg 2008; 34:601-607. This study shows clinical results of a new toric IOL and a review of the outcomes found in previous studies using different toric IOLs.
    • • Mendicute J, Irigoyen C, Aramberri J, et al. Foldable toric intraocular lens for astigmatism correction in cataract patients. J Cataract Refract Surg 2008; 34:601-607. This study shows clinical results of a new toric IOL and a review of the outcomes found in previous studies using different toric IOLs.
  • 14
    • 28844445177 scopus 로고    scopus 로고
    • Biometry of phakic intraocular lens using Scheimpflug photography
    • Coppens JE, van den Berg TJ, Budo CJ. Biometry of phakic intraocular lens using Scheimpflug photography. J Cataract Refract Surg 2005; 31:1904-1914.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1904-1914
    • Coppens, J.E.1    van den Berg, T.J.2    Budo, C.J.3
  • 15
    • 0035318125 scopus 로고    scopus 로고
    • Biometry of 3 types of intraocular lenses using Scheimpflug photography
    • Kim JS, Shyn KH. Biometry of 3 types of intraocular lenses using Scheimpflug photography. J Cataract Refract Surg 2001; 27:533-536.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 533-536
    • Kim, J.S.1    Shyn, K.H.2
  • 16
    • 34250630031 scopus 로고    scopus 로고
    • Intraocular lens centration and visual outcomes after bag-in-the-lens implantation
    • Verbruggen KH, Rozema JJ, Gobin L, et al. Intraocular lens centration and visual outcomes after bag-in-the-lens implantation. J Cataract Refract Surg 2007;33:1267-1272.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1267-1272
    • Verbruggen, K.H.1    Rozema, J.J.2    Gobin, L.3
  • 17
    • 0031716492 scopus 로고    scopus 로고
    • The role of capsulotomy and intraocular lens type on tilt and decentration of polymethylmethacrylate and foldable acrylic lenses
    • Mutlu FM, Bilge AH, Altinsoy HI, Yumusak E. The role of capsulotomy and intraocular lens type on tilt and decentration of polymethylmethacrylate and foldable acrylic lenses. Ophthalmologica 1998; 212:359-363.
    • (1998) Ophthalmologica , vol.212 , pp. 359-363
    • Mutlu, F.M.1    Bilge, A.H.2    Altinsoy, H.I.3    Yumusak, E.4
  • 18
    • 11844249983 scopus 로고    scopus 로고
    • Comparison of tilt and decentration between phacoemulsification and phacotrabeculectomy
    • Mutlu FM, Bayer A, Erduman C, Bayraktar MZ. Comparison of tilt and decentration between phacoemulsification and phacotrabeculectomy. Ophthalmologica 2005; 219:26-29.
    • (2005) Ophthalmologica , vol.219 , pp. 26-29
    • Mutlu, F.M.1    Bayer, A.2    Erduman, C.3    Bayraktar, M.Z.4
  • 19
    • 34247464661 scopus 로고    scopus 로고
    • Rotational stability of a single-piece hydrophobic acrylic intraocular lens: New method for high-precision rotation control
    • Weinand F, Jung A, Stein A, et al. Rotational stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control. J Cataract Refract Surg 2007; 33:800-803.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 800-803
    • Weinand, F.1    Jung, A.2    Stein, A.3
  • 20
    • 33644887427 scopus 로고    scopus 로고
    • Impact of the eye's cyclorotation on axial orientation analysis of toric intraocular lenses: Recommendations for an optimized evaluation of rotational stability of toric IOLs
    • Viestenz A, Langenbucher A, Seitz B, Viestenz A. Impact of the eye's cyclorotation on axial orientation analysis of toric intraocular lenses: recommendations for an optimized evaluation of rotational stability of toric IOLs. Klin Monatsbl Augenheilkd 2006; 223:134-140.
    • (2006) Klin Monatsbl Augenheilkd , vol.223 , pp. 134-140
    • Viestenz, A.1    Langenbucher, A.2    Seitz, B.3    Viestenz, A.4
  • 21
    • 0033504828 scopus 로고    scopus 로고
    • Postoperative intraocular lens rotation: A randomized comparison of plate and loop haptic implants
    • Patel CK, Ormonde S, Rosen PH, Bron AJ. Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants. Ophthalmology 1999; 106:2190-2195.
    • (1999) Ophthalmology , vol.106 , pp. 2190-2195
    • Patel, C.K.1    Ormonde, S.2    Rosen, P.H.3    Bron, A.J.4
  • 22
    • 15044359338 scopus 로고    scopus 로고
    • Comparison of the stability of 1 -piece and 3-piece acrylic intraocular lenses in the lens capsule
    • Hayashi K, Hayashi H. Comparison of the stability of 1 -piece and 3-piece acrylic intraocular lenses in the lens capsule. J Cataract Refract Surg 2005; 31:337-342.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 337-342
    • Hayashi, K.1    Hayashi, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.