-
1
-
-
0031018024
-
Stent thrombosis. Closing in on the best preventive treatment
-
Baim DS, Carrozza JP Jr. Stent thrombosis. Closing in on the best preventive treatment. Circulation 1997;95:1098-1100.
-
(1997)
Circulation
, vol.95
, pp. 1098-1100
-
-
Baim, D.S.1
Carrozza Jr., J.P.2
-
2
-
-
0029814641
-
Platelet activation and coronary stent implantation. Effect of antithrombotic therapy
-
Gawaz M, Neumann FJ, Ott I, May A, Schomig A. Platelet activation and coronary stent implantation. Effect of antithrombotic therapy. Circulation 1996;94:279-285.
-
(1996)
Circulation
, vol.94
, pp. 279-285
-
-
Gawaz, M.1
Neumann, F.J.2
Ott, I.3
May, A.4
Schomig, A.5
-
3
-
-
10144234792
-
Intracoronary stent implantation without ultrasound guidance and with replacement of conventional anticoagulation by antiplatelet therapy. 30day clinical outcome of the French Multicenter Registry
-
Karrillon GJ, Morice MC, Benveniste E, et al. Intracoronary stent implantation without ultrasound guidance and with replacement of conventional anticoagulation by antiplatelet therapy. 30day clinical outcome of the French Multicenter Registry. Circulation 1996;94:1519-1527.
-
(1996)
Circulation
, vol.94
, pp. 1519-1527
-
-
Karrillon, G.J.1
Morice, M.C.2
Benveniste, E.3
-
4
-
-
0028912131
-
Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance
-
Colombo A, Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, Gaglione A, Goldberg SL, Tobis JM. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation 1995;91:1676-1688.
-
(1995)
Circulation
, vol.91
, pp. 1676-1688
-
-
Colombo, A.1
Hall, P.2
Nakamura, S.3
Almagor, Y.4
Maiello, L.5
Martini, G.6
Gaglione, A.7
Goldberg, S.L.8
Tobis, J.M.9
-
5
-
-
9244251971
-
A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary-artery stents
-
Schomig A, Neumann FJ, Kastrati A, et al. A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary-artery stents. N Engl J Med 1996;334:1084-1089.
-
(1996)
N Engl J Med
, vol.334
, pp. 1084-1089
-
-
Schomig, A.1
Neumann, F.J.2
Kastrati, A.3
-
6
-
-
7844220998
-
Randomized multicenter comparison of conventional anticoagulation versus antiplatelet therapy in unplanned and elective coronary stenting. The full anticoagulation versus aspirin and ticlopidine (fantastic) study
-
Bertrand ME, Legrand V, Boland J, et al. Randomized multicenter comparison of conventional anticoagulation versus antiplatelet therapy in unplanned and elective coronary stenting. The full anticoagulation versus aspirin and ticlopidine (fantastic) study. Circulation 1998;98:1597-1603.
-
(1998)
Circulation
, vol.98
, pp. 1597-1603
-
-
Bertrand, M.E.1
Legrand, V.2
Boland, J.3
-
7
-
-
0032481092
-
A clinical trial comparing three antithrombotic-drug regimens after coronary-artery stenting. Stent Anticoagulation Restenosis Study Investigators
-
Leon MB, Baim DS, Popma JJ, et al. A clinical trial comparing three antithrombotic-drug regimens after coronary-artery stenting. Stent Anticoagulation Restenosis Study Investigators. N Engl J Med 1998;339:1665-1671.
-
(1998)
N Engl J Med
, vol.339
, pp. 1665-1671
-
-
Leon, M.B.1
Baim, D.S.2
Popma, J.J.3
-
8
-
-
0035876017
-
Incidence of thrombotic occlusion and major adverse cardiac events between two and four weeks after coronary stent placement: Analysis of 5,678 patients with a four-week ticlopidine regimen
-
Schuhlen H, Kastrati A, Pache J, Dirschinger J, Schomig A. Incidence of thrombotic occlusion and major adverse cardiac events between two and four weeks after coronary stent placement: analysis of 5,678 patients with a four-week ticlopidine regimen. J Am Coll Cardiol 2001;37:2066-2073.
-
(2001)
J Am Coll Cardiol
, vol.37
, pp. 2066-2073
-
-
Schuhlen, H.1
Kastrati, A.2
Pache, J.3
Dirschinger, J.4
Schomig, A.5
-
9
-
-
0031018569
-
Results of a consecutive series of patients receiving only antiplatelet therapy after optimized stent implantation. Comparison of aspirin alone versus combined ticlopidine and aspirin therapy
-
Albiero R, Hall P, Itoh A, Blengino S, Nakamura S, Martini G, Ferraro M, Colombo A. Results of a consecutive series of patients receiving only antiplatelet therapy after optimized stent implantation. Comparison of aspirin alone versus combined ticlopidine and aspirin therapy. Circulation 1997;95:1145-1156.
-
(1997)
Circulation
, vol.95
, pp. 1145-1156
-
-
Albiero, R.1
Hall, P.2
Itoh, A.3
Blengino, S.4
Nakamura, S.5
Martini, G.6
Ferraro, M.7
Colombo, A.8
-
10
-
-
0033545889
-
Effectiveness of clopidogrel and aspirin versus ticlopidine and aspirin in preventing stent thrombosis after coronary stent implantation
-
Moussa I, Oetgen M, Roubin G, Colombo A, Wang X, Iyer S, Maida R, Collins M, Kreps E, Moses JW. Effectiveness of clopidogrel and aspirin versus ticlopidine and aspirin in preventing stent thrombosis after coronary stent implantation. Circulation 1999;99:2364-2366.
-
(1999)
Circulation
, vol.99
, pp. 2364-2366
-
-
Moussa, I.1
Oetgen, M.2
Roubin, G.3
Colombo, A.4
Wang, X.5
Iyer, S.6
Maida, R.7
Collins, M.8
Kreps, E.9
Moses, J.W.10
-
11
-
-
0030070652
-
A randomized comparison of combined ticlopidine and aspirin therapy versus aspirin therapy alone after successful intravascular ultrasound-guided stent implantation
-
Hall P, Nakamura S, Maiello L, Itoh A, Blengino S, Martini G, Ferraro M, Colombo A. A randomized comparison of combined ticlopidine and aspirin therapy versus aspirin therapy alone after successful intravascular ultrasound-guided stent implantation. Circulation 1996;93:215-222.
-
(1996)
Circulation
, vol.93
, pp. 215-222
-
-
Hall, P.1
Nakamura, S.2
Maiello, L.3
Itoh, A.4
Blengino, S.5
Martini, G.6
Ferraro, M.7
Colombo, A.8
-
12
-
-
0343750695
-
A randomized comparison of clopidogrel and aspirin versus ticlopidine and aspirin after the placement of coronary-artery stents
-
Muller C, Buttner HJ, Petersen J, Roskamm H. A randomized comparison of clopidogrel and aspirin versus ticlopidine and aspirin after the placement of coronary-artery stents. Circulation 2000;101:590-593.
-
(2000)
Circulation
, vol.101
, pp. 590-593
-
-
Muller, C.1
Buttner, H.J.2
Petersen, J.3
Roskamm, H.4
-
13
-
-
0035901621
-
Stent thrombosis in the modern era: A pooled analysis of multicenter coronary stent clinical trials
-
Cutlip DE, Baim DS, Ho KK, Popma JJ, Lansky AJ, Cohen DJ, Carrozza JP Jr, Chauhan MS, Rodriguez O, Kuntz RE. Stent thrombosis in the modern era: A pooled analysis of multicenter coronary stent clinical trials. Circulation 2001;103:1967-1971.
-
(2001)
Circulation
, vol.103
, pp. 1967-1971
-
-
Cutlip, D.E.1
Baim, D.S.2
Ho, K.K.3
Popma, J.J.4
Lansky, A.J.5
Cohen, D.J.6
Carrozza Jr, J.P.7
Chauhan, M.S.8
Rodriguez, O.9
Kuntz, R.E.10
-
14
-
-
9144255404
-
Unrestricted utilization of sirolimus-eluting stents compared with conventional bare stent implantation in the "real world": The Rapamycin- Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry
-
Lemos PA, Serruys PW, van Domburg RT, et al. Unrestricted utilization of sirolimus-eluting stents compared with conventional bare stent implantation in the "real world": the Rapamycin- Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. Circulation 2004;109:190-195.
-
(2004)
Circulation
, vol.109
, pp. 190-195
-
-
Lemos, P.A.1
Serruys, P.W.2
van Domburg, R.T.3
-
15
-
-
2342645995
-
Incidence of thrombotic stent occlusion during the first three months after sirolimus-eluting stent implantation in 500 consecutive patients
-
Regar E, Lemos PA, Saia F, et al. Incidence of thrombotic stent occlusion during the first three months after sirolimus-eluting stent implantation in 500 consecutive patients. Am J Cardiol 2004;93:1271-1275.
-
(2004)
Am J Cardiol
, vol.93
, pp. 1271-1275
-
-
Regar, E.1
Lemos, P.A.2
Saia, F.3
-
16
-
-
11144356029
-
Stent thrombosis after successful sirolimus-eluting stent implantation
-
Jeremias A, Sylvia B, Bridges J, et al. Stent thrombosis after successful sirolimus-eluting stent implantation. Circulation 2004; 109:1930-1932.
-
(2004)
Circulation
, vol.109
, pp. 1930-1932
-
-
Jeremias, A.1
Sylvia, B.2
Bridges, J.3
-
17
-
-
0037030658
-
A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
-
Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773-1780.
-
(2002)
N Engl J Med
, vol.346
, pp. 1773-1780
-
-
Morice, M.C.1
Serruys, P.W.2
Sousa, J.E.3
-
18
-
-
0141765805
-
Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
-
Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-1323.
-
(2003)
N Engl J Med
, vol.349
, pp. 1315-1323
-
-
Moses, J.W.1
Leon, M.B.2
Popma, J.J.3
-
19
-
-
9144249927
-
A polymer-based, paclitaxel- eluting stent in patients with coronary artery disease
-
Stone GW, Ellis SG, Cox DA, et al. A polymer-based, paclitaxel- eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221-231.
-
(2004)
N Engl J Med
, vol.350
, pp. 221-231
-
-
Stone, G.W.1
Ellis, S.G.2
Cox, D.A.3
-
20
-
-
20044366366
-
Thirty-day incidence and sixmonth clinical outcome of thrombotic stent occlusion after baremetal, sirolimus, or paclitaxel stent implantation
-
Ong AT, Hoye A, Aoki J, et al. Thirty-day incidence and sixmonth clinical outcome of thrombotic stent occlusion after baremetal, sirolimus, or paclitaxel stent implantation. J Am Coll Cardiol 2005;45:947-953.
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 947-953
-
-
Ong, A.T.1
Hoye, A.2
Aoki, J.3
-
21
-
-
0037489288
-
Stent thrombosis: An issue revisited a changing world
-
Honda Y, Fitzgerald PJ. Stent thrombosis: An issue revisited a changing world. Circulation 2003;108:2-5.
-
(2003)
Circulation
, vol.108
, pp. 2-5
-
-
Honda, Y.1
Fitzgerald, P.J.2
-
23
-
-
0038300675
-
Predictors of subacute stent thrombosis: Results of a systematic intravascular ultrasound study
-
Cheneau E, Leborgne L, Mintz GS, Kotani J, Pichard AD, Satler LF, Canos D, Castagna M, Weissman NJ, Waksman R. Predictors of subacute stent thrombosis: Results of a systematic intravascular ultrasound study. Circulation 2003;108:43-47.
-
(2003)
Circulation
, vol.108
, pp. 43-47
-
-
Cheneau, E.1
Leborgne, L.2
Mintz, G.S.3
Kotani, J.4
Pichard, A.D.5
Satler, L.F.6
Canos, D.7
Castagna, M.8
Weissman, N.J.9
Waksman, R.10
-
24
-
-
0031022480
-
Subacute stent thrombosis in the era of intravascular ultrasound-guided coronary stenting without anticoagulation: Frequency, predictors and clinical outcome
-
Moussa I, Di Mario C, Reimers B, Akiyama T, Tobis J, Colombo A. Subacute stent thrombosis in the era of intravascular ultrasound-guided coronary stenting without anticoagulation: Frequency, predictors and clinical outcome. J Am Coll Cardiol 1997;29:6-12.
-
(1997)
J Am Coll Cardiol
, vol.29
, pp. 6-12
-
-
Moussa, I.1
Di Mario, C.2
Reimers, B.3
Akiyama, T.4
Tobis, J.5
Colombo, A.6
-
25
-
-
0036401717
-
Predictors and outcomes of stent thrombosis: An intravascular ultrasound registry
-
Uren NG, Schwarzacher SP, Metz JA, Lee DP, Honda Y, Yeung AC, Fitzgerald PJ, Yock PG. Predictors and outcomes of stent thrombosis: An intravascular ultrasound registry. Eur Heart J 2002;23:124-132.
-
(2002)
Eur Heart J
, vol.23
, pp. 124-132
-
-
Uren, N.G.1
Schwarzacher, S.P.2
Metz, J.A.3
Lee, D.P.4
Honda, Y.5
Yeung, A.C.6
Fitzgerald, P.J.7
Yock, P.G.8
-
26
-
-
20444500797
-
Validation of predictors of intraprocedural stent thrombosis in the drug-eluting stent era
-
Biondi-Zoccai GG, Sangiorgi GM, Chieffo A, et al. Validation of predictors of intraprocedural stent thrombosis in the drug-eluting stent era. Am J Cardiol 2005;95:1466-1468.
-
(2005)
Am J Cardiol
, vol.95
, pp. 1466-1468
-
-
Biondi-Zoccai, G.G.1
Sangiorgi, G.M.2
Chieffo, A.3
-
27
-
-
0028200199
-
Predictors of thrombotic complications after placement of the flexible coil stent
-
Agrawal SK, Ho DS, Liu MW, Iyer S, Hearn JA, Cannon AD, Macander PJ, Dean LS, Baxley WA, Roubin GS. Predictors of thrombotic complications after placement of the flexible coil stent. Am J Cardiol 1994;73:1216-1219.
-
(1994)
Am J Cardiol
, vol.73
, pp. 1216-1219
-
-
Agrawal, S.K.1
Ho, D.S.2
Liu, M.W.3
Iyer, S.4
Hearn, J.A.5
Cannon, A.D.6
Macander, P.J.7
Dean, L.S.8
Baxley, W.A.9
Roubin, G.S.10
-
28
-
-
0027394275
-
Thrombosis of a flexible coil coronary stent: Frequency, predictors and clinical outcome
-
Nath FC, Muller DW, Ellis SG, Rosenschein U, Chapekis A, Quain L, Zimmerman C, Topol EJ. Thrombosis of a flexible coil coronary stent: Frequency, predictors and clinical outcome. J Am Coll Cardiol 1993;21:622-627.
-
(1993)
J Am Coll Cardiol
, vol.21
, pp. 622-627
-
-
Nath, F.C.1
Muller, D.W.2
Ellis, S.G.3
Rosenschein, U.4
Chapekis, A.5
Quain, L.6
Zimmerman, C.7
Topol, E.J.8
-
29
-
-
11144355993
-
Platelet aggregation according to body mass index in patients undergoing coronary stenting: Should clopidogrel loading-dose be weight adjusted?
-
Angiolillo DJ, Fernandez-Ortiz A, Bernardo E, Barrera Ramirez C, Sabate M, Fernandez C, Hernandez-Antolin R, Escaned J, Alfonso F, Macaya C. Platelet aggregation according to body mass index in patients undergoing coronary stenting: Should clopidogrel loading-dose be weight adjusted? J Invasive Cardiol 2004;16:169-174.
-
(2004)
J Invasive Cardiol
, vol.16
, pp. 169-174
-
-
Angiolillo, D.J.1
Fernandez-Ortiz, A.2
Bernardo, E.3
Barrera Ramirez, C.4
Sabate, M.5
Fernandez, C.6
Hernandez-Antolin, R.7
Escaned, J.8
Alfonso, F.9
Macaya, C.10
-
30
-
-
33745960402
-
Prevalence, predictors, and outcomes of premature discontinuation of thienopyridine therapy after drug-eluting stent placement: Results from the PREMIER registry
-
Spertus JA, Kettelkamp R, Vance C, et al. Prevalence, predictors, and outcomes of premature discontinuation of thienopyridine therapy after drug-eluting stent placement: Results from the PREMIER registry. Circulation 2006;113:2803-2809.
-
(2006)
Circulation
, vol.113
, pp. 2803-2809
-
-
Spertus, J.A.1
Kettelkamp, R.2
Vance, C.3
-
31
-
-
20244377701
-
Guidelines for percutaneous coronary interventions. The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology
-
Silber S, Albertsson P, Aviles FF, et al. Guidelines for percutaneous coronary interventions. The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology. Eur Heart J 2005;26:804-847.
-
(2005)
Eur Heart J
, vol.26
, pp. 804-847
-
-
Silber, S.1
Albertsson, P.2
Aviles, F.F.3
-
32
-
-
33847167065
-
Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study
-
Daemen J, Wenaweser P, Tsuchida K, et al. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study. Lancet 2007;369:667-678.
-
(2007)
Lancet
, vol.369
, pp. 667-678
-
-
Daemen, J.1
Wenaweser, P.2
Tsuchida, K.3
-
33
-
-
20844445776
-
Stent thrombosis following bare-metal stent implantation: Success of emergency percutaneous coronary intervention and predictors of adverse outcome
-
Wenaweser P, Rey C, Eberli FR, et al. Stent thrombosis following bare-metal stent implantation: Success of emergency percutaneous coronary intervention and predictors of adverse outcome. Eur Heart J 2005;26:1180-1187.
-
(2005)
Eur Heart J
, vol.26
, pp. 1180-1187
-
-
Wenaweser, P.1
Rey, C.2
Eberli, F.R.3
-
34
-
-
42149119040
-
Intensive oral antiplatelet therapy for reduction of ischaemic events including stent thrombosis in patients with acute coronary syndromes treated with percutaneous coronary intervention and stenting in the TRITON-TIMI 38 trial: A subanalysis of a randomised trial
-
Wiviott SD, Braunwald E, McCabe CH, et al. Intensive oral antiplatelet therapy for reduction of ischaemic events including stent thrombosis in patients with acute coronary syndromes treated with percutaneous coronary intervention and stenting in the TRITON-TIMI 38 trial: A subanalysis of a randomised trial. Lancet 2008;371:1353-1363.
-
(2008)
Lancet
, vol.371
, pp. 1353-1363
-
-
Wiviott, S.D.1
Braunwald, E.2
McCabe, C.H.3
-
35
-
-
0031586491
-
Platelet glycoprotein IIIa polymorphisms and risk of coronary stent thrombosis
-
Walter DH, Schachinger V, Elsner M, Dimmeler S, Zeiher AM. Platelet glycoprotein IIIa polymorphisms and risk of coronary stent thrombosis. Lancet 1997;350:1217-1219.
-
(1997)
Lancet
, vol.350
, pp. 1217-1219
-
-
Walter, D.H.1
Schachinger, V.2
Elsner, M.3
Dimmeler, S.4
Zeiher, A.M.5
-
36
-
-
0029875770
-
A polymorphism of a platelet glycoprotein receptor as an inherited risk factor for coronary thrombosis
-
Weiss EJ, Bray PF, Tayback M, Schulman SP, Kickler TS, Becker LC, Weiss JL, Gerstenblith G, Goldschmidt-Clermont PJ. A polymorphism of a platelet glycoprotein receptor as an inherited risk factor for coronary thrombosis. N Engl J Med 1996;334:1090-1094.
-
(1996)
N Engl J Med
, vol.334
, pp. 1090-1094
-
-
Weiss, E.J.1
Bray, P.F.2
Tayback, M.3
Schulman, S.P.4
Kickler, T.S.5
Becker, L.C.6
Weiss, J.L.7
Gerstenblith, G.8
Goldschmidt-Clermont, P.J.9
-
38
-
-
0036846748
-
Aspirin resistance in cardiovascular disease: A review of prevalence, mechanisms, and clinical significance
-
McKee SA, Sane DC, Deliargyris EN. Aspirin resistance in cardiovascular disease: A review of prevalence, mechanisms, and clinical significance. Thromb Haemost 2002;88:711-715.
-
(2002)
Thromb Haemost
, vol.88
, pp. 711-715
-
-
McKee, S.A.1
Sane, D.C.2
Deliargyris, E.N.3
-
39
-
-
0038649988
-
Clopidogrel for coronary stenting: Response variability, drug resistance, and the effect of pretreatment platelet reactivity
-
Gurbel PA, Bliden KP, Hiatt BL, O'Connor CM. Clopidogrel for coronary stenting: Response variability, drug resistance, and the effect of pretreatment platelet reactivity. Circulation 2003; 107:2908-2913.
-
(2003)
Circulation
, vol.107
, pp. 2908-2913
-
-
Gurbel, P.A.1
Bliden, K.P.2
Hiatt, B.L.3
O'Connor, C.M.4
-
40
-
-
15944383861
-
Flow cytometric analysis of intraplatelet VASP phosphorylation for the detection of clopidogrel resistance in patients with ischemic cardiovascular diseases
-
Aleil B, Ravanat C, Cazenave JP, Rochoux G, Heitz A, Gachet C. Flow cytometric analysis of intraplatelet VASP phosphorylation for the detection of clopidogrel resistance in patients with ischemic cardiovascular diseases. J Thromb Haemost 2005;3:85-92.
-
(2005)
J Thromb Haemost
, vol.3
, pp. 85-92
-
-
Aleil, B.1
Ravanat, C.2
Cazenave, J.P.3
Rochoux, G.4
Heitz, A.5
Gachet, C.6
-
41
-
-
20344394411
-
Enhanced shear-induced platelet aggregation in patients who experience subacute stent thrombosis: A case-control study
-
Ajzenberg N, Aubry P, Huisse MG, Cachier A, El Amara W, Feldman LJ, Himbert D, Baruch D, Guillin MC, Steg PG. Enhanced shear-induced platelet aggregation in patients who experience subacute stent thrombosis: A case-control study. J Am Coll Cardiol 2005;45:1753-1756.
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 1753-1756
-
-
Ajzenberg, N.1
Aubry, P.2
Huisse, M.G.3
Cachier, A.4
El Amara, W.5
Feldman, L.J.6
Himbert, D.7
Baruch, D.8
Guillin, M.C.9
Steg, P.G.10
-
42
-
-
20344408497
-
Stent thrombosis is associated with an impaired response to antiplatelet therapy
-
Wenaweser P, Dorffler-Melly J, Imboden K, Windecker S, Togni M, Meier B, Haeberli A, Hess OM. Stent thrombosis is associated with an impaired response to antiplatelet therapy. J Am Coll Cardiol 2005;45:1748-1752.
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 1748-1752
-
-
Wenaweser, P.1
Dorffler-Melly, J.2
Imboden, K.3
Windecker, S.4
Togni, M.5
Meier, B.6
Haeberli, A.7
Hess, O.M.8
-
43
-
-
0038354521
-
Resistance to thienopyridines: Clinical detection of coronary stent thrombosis by monitoring of vasodilator-stimulated phosphoprotein phosphorylation
-
Barragan P, Bouvier JL, Roquebert PO, Macaluso G, Commeau P, Comet B, Lafont A, Camoin L, Walter U, Eigenthaler M. Resistance to thienopyridines: Clinical detection of coronary stent thrombosis by monitoring of vasodilator-stimulated phosphoprotein phosphorylation. Catheter Cardiovasc Interv 2003;59:295-302.
-
(2003)
Catheter Cardiovasc Interv
, vol.59
, pp. 295-302
-
-
Barragan, P.1
Bouvier, J.L.2
Roquebert, P.O.3
Macaluso, G.4
Commeau, P.5
Comet, B.6
Lafont, A.7
Camoin, L.8
Walter, U.9
Eigenthaler, M.10
-
44
-
-
8344221349
-
Clopidogrel resistance is associated with increased risk of recurrent atherothrombotic events in patients with acute myocardial infarction
-
Matetzky S, Shenkman B, Guetta V, et al. Clopidogrel resistance is associated with increased risk of recurrent atherothrombotic events in patients with acute myocardial infarction. Circulation 2004;109:3171-3175.
-
(2004)
Circulation
, vol.109
, pp. 3171-3175
-
-
Matetzky, S.1
Shenkman, B.2
Guetta, V.3
-
45
-
-
42249085250
-
Does IVUS guidance of coronary interventions affect outcome? a prime example of the failure of randomized clinical trials
-
Gerber R, Colombo A. Does IVUS guidance of coronary interventions affect outcome? a prime example of the failure of randomized clinical trials. Catheter Cardiovasc Interv 2008;71: 646-654.
-
(2008)
Catheter Cardiovasc Interv
, vol.71
, pp. 646-654
-
-
Gerber, R.1
Colombo, A.2
-
46
-
-
0037422555
-
Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: Final results of a randomized comparison with angiographic guidance (TULIP Study)
-
Oemrawsingh PV, Mintz GS, Schalij MJ, Zwinderman AH, Jukema JW, van der Wall EE. Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: Final results of a randomized comparison with angiographic guidance (TULIP Study). Circulation 2003;107:62-67.
-
(2003)
Circulation
, vol.107
, pp. 62-67
-
-
Oemrawsingh, P.V.1
Mintz, G.S.2
Schalij, M.J.3
Zwinderman, A.H.4
Jukema, J.W.5
van der Wall, E.E.6
-
47
-
-
0035908974
-
Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study)
-
Mudra H, di Mario C, de Jaegere P, et al. Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study). Circulation 2001;104:1343-1349.
-
(2001)
Circulation
, vol.104
, pp. 1343-1349
-
-
Mudra, H.1
di Mario, C.2
de Jaegere, P.3
-
48
-
-
0032145711
-
Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: A multicenter, randomized study comparing two strategies-with and without intravascular ultrasound guidance. RESIST Study Group. REStenosis after Ivus guided STenting
-
Schiele F, Meneveau N, Vuillemenot A, Zhang DD, Gupta S, Mercier M, Danchin N, Bertrand B, Bassand JP. Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: A multicenter, randomized study comparing two strategies-with and without intravascular ultrasound guidance. RESIST Study Group. REStenosis after Ivus guided STenting. J Am Coll Cardiol 1998;32:320-328.
-
(1998)
J Am Coll Cardiol
, vol.32
, pp. 320-328
-
-
Schiele, F.1
Meneveau, N.2
Vuillemenot, A.3
Zhang, D.D.4
Gupta, S.5
Mercier, M.6
Danchin, N.7
Bertrand, B.8
Bassand, J.P.9
-
49
-
-
34547760330
-
A comparison of six major platelet function tests to determine the prevalence of aspirin resistance in patients with stable coronary artery disease
-
Lordkipanidze M, Pharand C, Schampaert E, Turgeon J, Palisaitis DA, Diodati JG. A comparison of six major platelet function tests to determine the prevalence of aspirin resistance in patients with stable coronary artery disease. Eur Heart J 2007;28:1702-1708.
-
(2007)
Eur Heart J
, vol.28
, pp. 1702-1708
-
-
Lordkipanidze, M.1
Pharand, C.2
Schampaert, E.3
Turgeon, J.4
Palisaitis, D.A.5
Diodati, J.G.6
-
50
-
-
0036623670
-
The prognostic value of pre-procedural plasma C-reactive protein in patients undergoing elective coronary angioplasty
-
de Winter RJ, Heyde GS, Koch KT, et al. The prognostic value of pre-procedural plasma C-reactive protein in patients undergoing elective coronary angioplasty. Eur Heart J 2002;23:960-966.
-
(2002)
Eur Heart J
, vol.23
, pp. 960-966
-
-
de Winter, R.J.1
Heyde, G.S.2
Koch, K.T.3
|