메뉴 건너뛰기




Volumn 54, Issue 1, 2009, Pages 103-107

STR profiles from DNA samples with "undetected" or low quantifiler™ results

Author keywords

DNA quantitation; DNA typing; Forensic science; Low level DNA; Quantifiler ; Quantitative polymerase chain reaction

Indexed keywords

DNA;

EID: 58149186843     PISSN: 00221198     EISSN: 15564029     Source Type: Journal    
DOI: 10.1111/j.1556-4029.2008.00914.x     Document Type: Article
Times cited : (38)

References (17)
  • 1
    • 0027318997 scopus 로고
    • DNA typing with fluorescently tagged short tandem repeats: A sensitive and accurate approach to human identification
    • Fregeau CJ, Fourney RM. DNA typing with fluorescently tagged short tandem repeats: a sensitive and accurate approach to human identification. Biotechniques 1993 15 (1 100 19.
    • (1993) Biotechniques , vol.15 , Issue.1 , pp. 100-19
    • Fregeau, C.J.1    Fourney, R.M.2
  • 2
    • 0034990151 scopus 로고    scopus 로고
    • Validation of short tandem repeats (STRs) for forensic usage: Performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples
    • Moretti TR, Baumstark AL, Defenbaugh DA, Keys KM, Smerick JB, Budowle B. Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples. J Forensic Sci 2001 46 (3 647 60.
    • (2001) J Forensic Sci , vol.46 , Issue.3 , pp. 647-60
    • Moretti, T.R.1    Baumstark, A.L.2    Defenbaugh, D.A.3    Keys, K.M.4    Smerick, J.B.5    Budowle, B.6
  • 3
    • 0026670282 scopus 로고
    • A rapid chemiluminescent method for quantitation of human DNA
    • Walsh PS, Varlaro J, Reynolds R. A rapid chemiluminescent method for quantitation of human DNA. Nucleic Acids Res 1992 20 (19 5061 5.
    • (1992) Nucleic Acids Res , vol.20 , Issue.19 , pp. 5061-5
    • Walsh, P.S.1    Varlaro, J.2    Reynolds, R.3
  • 5
    • 21444458902 scopus 로고    scopus 로고
    • Developmental validation of the Quantifiler™ real-time PCR kits for the quantification of human nuclear DNA samples
    • Green RL, Roinestad IC, Boland C, Hennessy LK. Developmental validation of the Quantifiler™ real-time PCR kits for the quantification of human nuclear DNA samples. J Forensic Sci 2005 50 (4 809 25.
    • (2005) J Forensic Sci , vol.50 , Issue.4 , pp. 809-25
    • Green, R.L.1    Roinestad, I.C.2    Boland, C.3    Hennessy, L.K.4
  • 8
    • 24644516556 scopus 로고    scopus 로고
    • A duplex real-time qPCR assay for the quantification of human nuclear and mitochondrial DNA in forensic samples: Implications for quantifying DNA in degraded samples
    • Timken MD, Swango KL, Orrego C, Buoncristiani MR. A duplex real-time qPCR assay for the quantification of human nuclear and mitochondrial DNA in forensic samples: implications for quantifying DNA in degraded samples. J Forensic Sci 2005 50 (5 1044 60.
    • (2005) J Forensic Sci , vol.50 , Issue.5 , pp. 1044-60
    • Timken, M.D.1    Swango, K.L.2    Orrego, C.3    Buoncristiani, M.R.4
  • 9
    • 0345760064 scopus 로고    scopus 로고
    • Evaluation of an automated liquid hybridization method for DNA quantitation
    • Hayn S, Wallace MM, Prinz M, Shaler RC. Evaluation of an automated liquid hybridization method for DNA quantitation. J Forensic Sci 2004 49 (1 87 91.
    • (2004) J Forensic Sci , vol.49 , Issue.1 , pp. 87-91
    • Hayn, S.1    Wallace, M.M.2    Prinz, M.3    Shaler, R.C.4
  • 11
    • 0035187195 scopus 로고    scopus 로고
    • NIST mixed stain studies #1 and #2: Interlaboratory comparison of DNA quantitation practice and short tandem repeat multiplex performance with multiple source samples
    • Duewer DL, Kline MC, Redman JW, Newall PJ, Reeder DJ. NIST mixed stain studies #1 and #2: interlaboratory comparison of DNA quantitation practice and short tandem repeat multiplex performance with multiple source samples. J Forensic Sci 2001 46 (5 1199 210.
    • (2001) J Forensic Sci , vol.46 , Issue.5 , pp. 1199-210
    • Duewer, D.L.1    Kline, M.C.2    Redman, J.W.3    Newall, P.J.4    Reeder, D.J.5
  • 12
    • 0038629348 scopus 로고    scopus 로고
    • NIST Mixed Stain Study 3: DNA quantitation accuracy and its influence on short tandem repeat multiplex signal intensity
    • Kline MC, Duewer DL, Redman JW, Butler JM. NIST Mixed Stain Study 3: DNA quantitation accuracy and its influence on short tandem repeat multiplex signal intensity. Anal Chem 2003 75 (10 2463 9.
    • (2003) Anal Chem , vol.75 , Issue.10 , pp. 2463-9
    • Kline, M.C.1    Duewer, D.L.2    Redman, J.W.3    Butler, J.M.4
  • 13
    • 24744452181 scopus 로고    scopus 로고
    • Obtaining typable DNA from bloodstains that serologically test negative
    • Coy KL, Lewis KE, Fulmer A, Hudson A, Dawson Cruz T. Obtaining typable DNA from bloodstains that serologically test negative. J Forensic Ident 2005 55 (5 633 42.
    • (2005) J Forensic Ident , vol.55 , Issue.5 , pp. 633-42
    • Coy, K.L.1    Lewis, K.E.2    Fulmer, A.3    Hudson, A.4    Dawson Cruz, T.5
  • 14
  • 15
    • 0031658736 scopus 로고    scopus 로고
    • QIAamp spin columns as a method of DNA isolation for forensic casework
    • Greenspoon SA, Scarpetta MA, Drayton ML, Turk SA. QIAamp spin columns as a method of DNA isolation for forensic casework. J Forensic Sci 1998 43 (5 1024 30.
    • (1998) J Forensic Sci , vol.43 , Issue.5 , pp. 1024-30
    • Greenspoon, S.A.1    Scarpetta, M.A.2    Drayton, M.L.3    Turk, S.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.