메뉴 건너뛰기




Volumn 32, Issue 1, 2009, Pages 119-130

Systematic comparisons of electrocardiographic morphology increase the precision of QT interval measurement

Author keywords

ECG morphology; Pattern matching; QTc variability; Thorough QT QTc study

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CONTROLLED STUDY; ELECTROCARDIOGRAM; ELECTROCARDIOGRAPHY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MORPHOLOGY; PARKINSON DISEASE; PATTERN RECOGNITION; POPULATION RESEARCH; QT INTERVAL;

EID: 58149177539     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2009.02185.x     Document Type: Article
Times cited : (36)

References (19)
  • 1
    • 27244456179 scopus 로고    scopus 로고
    • E14 Clinical evaluation of QT/QTc interval prolongation and proarrhythmic potential for non-antiarrhythmic drugs. Guidance to industry
    • E14 Clinical evaluation of QT/QTc interval prolongation and proarrhythmic potential for non-antiarrhythmic drugs. Guidance to industry. Fed Regist 2005 70 : 61134 61135.
    • (2005) Fed Regist , vol.70 , pp. 61134-61135
  • 2
    • 37549043173 scopus 로고    scopus 로고
    • Ritonavir 100 mg does not cause QTc prolongation in healthy subjects: A possible role as CYP3A inhibitor in thorough QTc studies
    • Sarapa N, Nickens DJ, Raber SR, Reynolds RR, Amantea MA. Ritonavir 100 mg does not cause QTc prolongation in healthy subjects: A possible role as CYP3A inhibitor in thorough QTc studies. Clin Pharmacol Ther 2008 83 : 153 159.
    • (2008) Clin Pharmacol Ther , vol.83 , pp. 153-159
    • Sarapa, N.1    Nickens, D.J.2    Raber, S.R.3    Reynolds, R.R.4    Amantea, M.A.5
  • 3
    • 37549017626 scopus 로고    scopus 로고
    • Randomized, double-blind, crossover study to investigate the effect of rivaroxaban on QT-interval prolongation
    • Kubitza D, Mueck W, Becka M. Randomized, double-blind, crossover study to investigate the effect of rivaroxaban on QT-interval prolongation. Drug Safety 2008 31 : 67 77.
    • (2008) Drug Safety , vol.31 , pp. 67-77
    • Kubitza, D.1    Mueck, W.2    Becka, M.3
  • 4
    • 35248869253 scopus 로고    scopus 로고
    • Levocetirizine does not prolong the QT/QTc interval in healthy subjects: Results from a thorough QT study
    • Hulhoven R, Rosillon D, Letiexhe M, Meeus MA, Daoust A, Stockis A. Levocetirizine does not prolong the QT/QTc interval in healthy subjects: Results from a thorough QT study. Eur J Clin Pharmacol 2007 63 : 1011 1017.
    • (2007) Eur J Clin Pharmacol , vol.63 , pp. 1011-1017
    • Hulhoven, R.1    Rosillon, D.2    Letiexhe, M.3    Meeus, M.A.4    Daoust, A.5    Stockis, A.6
  • 5
    • 0036181222 scopus 로고    scopus 로고
    • Relation between QT and RR intervals is highly individual among healthy subjects: Implications for heart rate correction of the QT interval
    • Malik M, Färbom P, Batchvarov V, Hnatkova K, Camm AJ. Relation between QT and RR intervals is highly individual among healthy subjects: Implications for heart rate correction of the QT interval. Heart 2002 87 : 220 228.
    • (2002) Heart , vol.87 , pp. 220-228
    • Malik, M.1    Färbom, P.2    Batchvarov, V.3    Hnatkova, K.4    Camm, A.J.5
  • 7
    • 33750718802 scopus 로고    scopus 로고
    • Precision of QT interval measurement by advanced electrocardiographic equipment
    • Hnatkova K, Gang Y, Batchvarov VN, Malik M. Precision of QT interval measurement by advanced electrocardiographic equipment. Pacing Clin Electrophysiol 2006 29 : 1277 1284.
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 1277-1284
    • Hnatkova, K.1    Gang, Y.2    Batchvarov, V.N.3    Malik, M.4
  • 9
    • 0032031794 scopus 로고    scopus 로고
    • Developments in ECG acquisition, preprocessing, parameter measurement, and recording
    • Daskalov IK, Dotsinsky IA, Christov II. Developments in ECG acquisition, preprocessing, parameter measurement, and recording. IEEE Eng Med Biol 1998 17 : 50 58.
    • (1998) IEEE Eng Med Biol , vol.17 , pp. 50-58
    • Daskalov, I.K.1    Dotsinsky, I.A.2    Christov, I.I.3
  • 10
    • 0017695924 scopus 로고
    • Electrocardiogram baseline noise estimation and removal using cubic splines and state-space computation techniques
    • Meyer CR, Keiser HN. Electrocardiogram baseline noise estimation and removal using cubic splines and state-space computation techniques. Comput Biomed Res 1977 10 : 459 470.
    • (1977) Comput Biomed Res , vol.10 , pp. 459-470
    • Meyer, C.R.1    Keiser, H.N.2
  • 11
    • 1942440785 scopus 로고    scopus 로고
    • Characterization of QT interval adaptation to RR interval changes and its use as a risk-stratifier of arrhythmic mortality in amiodarone-treated survivors of acute myocardial infarction
    • Pueyo E, Smetana P, Caminal P, de Luna AB, Malik M, Laguna P. Characterization of QT interval adaptation to RR interval changes and its use as a risk-stratifier of arrhythmic mortality in amiodarone-treated survivors of acute myocardial infarction. IEEE Trans Biomed Eng 2004 51 : 1511 1520.
    • (2004) IEEE Trans Biomed Eng , vol.51 , pp. 1511-1520
    • Pueyo, E.1    Smetana, P.2    Caminal, P.3    De Luna, A.B.4    Malik, M.5    Laguna, P.6
  • 12
    • 0035043773 scopus 로고    scopus 로고
    • Problems of heart rate correction in assessment of drug-induced QT interval prolongation
    • Malik M. Problems of heart rate correction in assessment of drug-induced QT interval prolongation. J Cardiovasc Electrophysiol 2001 12 : 411 420.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 411-420
    • Malik, M.1
  • 13
    • 84980098899 scopus 로고
    • Die Systolendauer im Elekrokardiogramm bei normalen Menschen und bei Herzkranken
    • Fridericia LS. Die Systolendauer im Elekrokardiogramm bei normalen Menschen und bei Herzkranken. Acta Med Scand 1920 53 : 469 486.
    • (1920) Acta Med Scand , vol.53 , pp. 469-486
    • Fridericia, L.S.1
  • 14
    • 45849094068 scopus 로고    scopus 로고
    • Statistical issues including design and sample size calculation in thorough QT/QTc studies
    • Zhang J, Machado SG. Statistical issues including design and sample size calculation in thorough QT/QTc studies. J Biopharm Stat 2008 18 : 451 467.
    • (2008) J Biopharm Stat , vol.18 , pp. 451-467
    • Zhang, J.1    MacHado, S.G.2
  • 15
    • 45849106884 scopus 로고    scopus 로고
    • Sample size calculations in thorough QT studies
    • Zhang L, Dmitrienko A, Luta G. Sample size calculations in thorough QT studies. J Biopharm Stat 2008 18 : 468 482.
    • (2008) J Biopharm Stat , vol.18 , pp. 468-482
    • Zhang, L.1    Dmitrienko, A.2    Luta, G.3
  • 16
    • 51849131559 scopus 로고    scopus 로고
    • Accurately measured and heart-rate corrected QTc intervals do not show any day-time variability
    • (abstract)
    • Malik M, Hnatkova K, Smetana P, Schmidt A. Accurately measured and heart-rate corrected QTc intervals do not show any day-time variability. (abstract) Eur Heart J 2007 28 : 624.
    • (2007) Eur Heart J , vol.28 , pp. 624
    • Malik, M.1    Hnatkova, K.2    Smetana, P.3    Schmidt, A.4
  • 17
    • 0036941017 scopus 로고    scopus 로고
    • Linearly scaled, rate-invariant normal limits for QT interval: Eight decades of incorrect application of power functions
    • Rautaharju PM, Zhang ZM. Linearly scaled, rate-invariant normal limits for QT interval: Eight decades of incorrect application of power functions. J Cardiovasc Electrophysiol 2002 13 : 1211 1218.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 1211-1218
    • Rautaharju, P.M.1    Zhang, Z.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.