메뉴 건너뛰기




Volumn 48, Issue 6, 2008, Pages 1609-1612

Endovascular repair of stent graft collapse by stent-protected angioplasty using a femoral-brachial guidewire

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANGIOPLASTY; ARTICLE; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; ENDOPROSTHESIS; GRAFT FAILURE; HUMAN; MALE; PRIORITY JOURNAL; STENT; STENT GRAFT COLLAPSE; SURGICAL TECHNIQUE; THORACIC AORTIC TRANSECTION; THORAX INJURY;

EID: 57949090976     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvs.2008.07.061     Document Type: Article
Times cited : (14)

References (17)
  • 3
    • 41149092308 scopus 로고    scopus 로고
    • Lessons learned from midterm follow-up of endovascular repair for traumatic rupture of the aortic isthmus
    • Canaud L., Alric P., Branchereau P., Marty-Ané C., and Berthet J.P. Lessons learned from midterm follow-up of endovascular repair for traumatic rupture of the aortic isthmus. J Vasc Surg 47 (2008) 733-738
    • (2008) J Vasc Surg , vol.47 , pp. 733-738
    • Canaud, L.1    Alric, P.2    Branchereau, P.3    Marty-Ané, C.4    Berthet, J.P.5
  • 4
    • 33947608981 scopus 로고    scopus 로고
    • Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture
    • Muhs B.E., Balm R., White G.H., and Verhagen H.J. Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture. J Vasc Surg 45 (2007) 655-661
    • (2007) J Vasc Surg , vol.45 , pp. 655-661
    • Muhs, B.E.1    Balm, R.2    White, G.H.3    Verhagen, H.J.4
  • 7
    • 33644675208 scopus 로고    scopus 로고
    • Endovascular repair of proximal endograft collapse after treatment for thoracic aortic disease
    • Steinbauer M.G., Stehr A., Pfister K., Herold T., Zorger N., Töpel I., et al. Endovascular repair of proximal endograft collapse after treatment for thoracic aortic disease. J Vasc Surg 43 (2006) 609-612
    • (2006) J Vasc Surg , vol.43 , pp. 609-612
    • Steinbauer, M.G.1    Stehr, A.2    Pfister, K.3    Herold, T.4    Zorger, N.5    Töpel, I.6
  • 8
    • 0036071967 scopus 로고    scopus 로고
    • Technical strategies to expand stent-graft applicability in the aortic arch and proximal descending thoracic aorta
    • Criado F.J., Barnatan M.F., Rizk Y., Clark N.S., and Wang C.F. Technical strategies to expand stent-graft applicability in the aortic arch and proximal descending thoracic aorta. J Endovasc Ther 9 Suppl 2 (2002) 32-38
    • (2002) J Endovasc Ther , vol.9 , Issue.SUPPL. 2 , pp. 32-38
    • Criado, F.J.1    Barnatan, M.F.2    Rizk, Y.3    Clark, N.S.4    Wang, C.F.5
  • 9
    • 0028631110 scopus 로고
    • Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms
    • Dake M.D., Miller D.C., Semba C.P., Mitchell R.S., Walker P.J., and Liddell R.P. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med 331 (1994) 1729-1734
    • (1994) N Engl J Med , vol.331 , pp. 1729-1734
    • Dake, M.D.1    Miller, D.C.2    Semba, C.P.3    Mitchell, R.S.4    Walker, P.J.5    Liddell, R.P.6
  • 12
    • 0033930117 scopus 로고    scopus 로고
    • Use of through-and-through guidewire for delivering large stent-grafts into the distal aortic arch
    • Al Shammari M., Taylor P., and Reidy J.F. Use of through-and-through guidewire for delivering large stent-grafts into the distal aortic arch. Cardiovasc Intervent Radiol 23 (2000) 237-238
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 237-238
    • Al Shammari, M.1    Taylor, P.2    Reidy, J.F.3
  • 13
    • 0029786213 scopus 로고    scopus 로고
    • Adenosine-induced transient cardiac asystole enhances precise deployment of stent-grafts in the thoracic or abdominal aorta
    • Dorros G., and Cohn J.M. Adenosine-induced transient cardiac asystole enhances precise deployment of stent-grafts in the thoracic or abdominal aorta. J Endovasc Surg 3 (1996) 270-272
    • (1996) J Endovasc Surg , vol.3 , pp. 270-272
    • Dorros, G.1    Cohn, J.M.2
  • 14
    • 34848840108 scopus 로고    scopus 로고
    • Rapid pacing for better placing: comparison of techniques for precise deployment of endografts in the thoracic aorta
    • Nienaber C.A., Kische S., Rehders T.C., Schneider H., Chatterjee T., Bünger C.M., et al. Rapid pacing for better placing: comparison of techniques for precise deployment of endografts in the thoracic aorta. J Endovasc Ther 14 (2007) 506-512
    • (2007) J Endovasc Ther , vol.14 , pp. 506-512
    • Nienaber, C.A.1    Kische, S.2    Rehders, T.C.3    Schneider, H.4    Chatterjee, T.5    Bünger, C.M.6
  • 16
    • 37249091708 scopus 로고    scopus 로고
    • Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. a study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) registry
    • Buth J., Harris P.L., Hobo R., van Eps R., Cuypers P., Duijm L., et al. Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. a study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) registry. J Vasc Surg 46 (2007) 1103-1111
    • (2007) J Vasc Surg , vol.46 , pp. 1103-1111
    • Buth, J.1    Harris, P.L.2    Hobo, R.3    van Eps, R.4    Cuypers, P.5    Duijm, L.6
  • 17
    • 47049105682 scopus 로고    scopus 로고
    • Proximal fixation of thoracic stent-grafts as a function of oversizing and increasing aortic arch angulation in human cadaveric aortas
    • Canaud L., Alric P., Laurent M., Baum T.P., Branchereau P., Marty-Ané C.H., et al. Proximal fixation of thoracic stent-grafts as a function of oversizing and increasing aortic arch angulation in human cadaveric aortas. J Endovasc Ther 15 (2008) 326-334
    • (2008) J Endovasc Ther , vol.15 , pp. 326-334
    • Canaud, L.1    Alric, P.2    Laurent, M.3    Baum, T.P.4    Branchereau, P.5    Marty-Ané, C.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.