메뉴 건너뛰기




Volumn 15, Issue 3, 2008, Pages 326-334

Proximal fixation of thoracic stent-grafts as a function of oversizing and increasing aortic arch angulation in human cadaveric aortas

Author keywords

Barbs; Fixation; Neck angulation; Oversizing; Pulsatile flow model; Stent graft; Thoracic aorta; Wall apposition

Indexed keywords

ADULT; AORTA ARCH ANOMALY; AORTA WALL; AORTIC ARCH ANGULATION; ARTICLE; BLOOD VESSEL GRAFT; CADAVER; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN TISSUE; MALE; MODEL; PRIORITY JOURNAL; PULSATILE FLOW; STENT; THORACIC AORTA; TREATMENT FAILURE;

EID: 47049105682     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/08-2425.1     Document Type: Article
Times cited : (63)

References (15)
  • 1
    • 12144276913 scopus 로고    scopus 로고
    • Endografting of the aortic arch
    • ll:ll-62-ll-71
    • Ishimaru S. Endografting of the aortic arch. J Endovasc Ther. 2004;11(Suppl ll):ll-62-ll-71.
    • (2004) J Endovasc Ther , vol.11 , Issue.SUPPL.
    • Ishimaru, S.1
  • 2
    • 4644314000 scopus 로고    scopus 로고
    • Endovascular treatment of thoracic aortic disease: Four years of experience
    • Bortone AS, De Cillis E, D'Agostino D, et al. Endovascular treatment of thoracic aortic disease: four years of experience. Circulation. 2004;110(11 Suppl 1):11262-267.
    • (2004) Circulation , vol.110 , Issue.11 SUPPL. 1 , pp. 11262-11267
    • Bortone, A.S.1    De Cillis, E.2    D'Agostino, D.3
  • 3
    • 0031647079 scopus 로고    scopus 로고
    • Endovascular AAA exclusion: Will stents with hooks and barbs prevent stent-graft migration?
    • Malina M, Lindblad B, Ivancev K, et al. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration? J Endovasc Surg. 1998;5:310-317.
    • (1998) J Endovasc Surg , vol.5 , pp. 310-317
    • Malina, M.1    Lindblad, B.2    Ivancev, K.3
  • 4
    • 4744341846 scopus 로고    scopus 로고
    • Endovascular treatment of thoracic aortic diseases: Combined experience from the EUROSTAR and United Kingdom Thoracic Endograft registries
    • Leurs LJ, Bell R, Degrieck Y, et al. Endovascular treatment of thoracic aortic diseases: combined experience from the EUROSTAR and United Kingdom Thoracic Endograft registries. J Vasc Surg. 2004;40:670-680.
    • (2004) J Vasc Surg , vol.40 , pp. 670-680
    • Leurs, L.J.1    Bell, R.2    Degrieck, Y.3
  • 5
    • 33744753401 scopus 로고    scopus 로고
    • Endovascular management of traumatic ruptures of the thoracic aorta: A retrospective multicenter analysis of 28 cases in The Netherlands
    • Hoornweg LL, Dinkelman MK, Goslings JC, et al. Endovascular management of traumatic ruptures of the thoracic aorta: a retrospective multicenter analysis of 28 cases in The Netherlands. J Vasc Surg. 2006;43:1096-1102.
    • (2006) J Vasc Surg , vol.43 , pp. 1096-1102
    • Hoornweg, L.L.1    Dinkelman, M.K.2    Goslings, J.C.3
  • 6
    • 1642535329 scopus 로고    scopus 로고
    • Improvement in proximal aortic endograft fixation: An experimental study using different stent-grafts in human cadaveric aortas
    • Veerapen R, Dorandeu A, Serre I, et al. Improvement in proximal aortic endograft fixation: an experimental study using different stent-grafts in human cadaveric aortas. J Endovasc Ther. 2003;10:1101-1109.
    • (2003) J Endovasc Ther , vol.10 , pp. 1101-1109
    • Veerapen, R.1    Dorandeu, A.2    Serre, I.3
  • 7
    • 33750967328 scopus 로고    scopus 로고
    • Evolution and future of preclinical testing for endovascular grafts
    • Abel DB, Dehdashtian MM, Rodger ST, et al. Evolution and future of preclinical testing for endovascular grafts. J Endovasc Ther. 2006;13:649-659.
    • (2006) J Endovasc Ther , vol.13 , pp. 649-659
    • Abel, D.B.1    Dehdashtian, M.M.2    Rodger, S.T.3
  • 8
    • 33144485919 scopus 로고    scopus 로고
    • Movement and dislocation of modular stent-grafts due to pulsatile flow and the pressure difference between the stent-graft and the aneurysm sac
    • Liffman K, Sutalo ID, Lawrence-Brown MM, et al. Movement and dislocation of modular stent-grafts due to pulsatile flow and the pressure difference between the stent-graft and the aneurysm sac. J Endovasc Ther. 2006;13:51-61.
    • (2006) J Endovasc Ther , vol.13 , pp. 51-61
    • Liffman, K.1    Sutalo, I.D.2    Lawrence-Brown, M.M.3
  • 9
    • 47049088809 scopus 로고    scopus 로고
    • Technical aspects of carotid stenting
    • Marco J, Serruys P, Biamino G, et al, eds, May
    • Yadav JS. Technical aspects of carotid stenting. In: Marco J, Serruys P, Biamino G, et al., eds. The Paris Course on Revascularization. May 2003.
    • (2003) The Paris Course on Revascularization
    • Yadav, J.S.1
  • 10
    • 0033845597 scopus 로고    scopus 로고
    • The impact of stent design on proximal stent-graft fixation in the abdominal aorta: An experimental study
    • Resch T, Malina M, Lindblad B, et al. The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study. Eur J Vasc Endovasc Surg. 2000;20:190-195.
    • (2000) Eur J Vasc Endovasc Surg , vol.20 , pp. 190-195
    • Resch, T.1    Malina, M.2    Lindblad, B.3
  • 11
    • 23344442479 scopus 로고    scopus 로고
    • Collapse of a stent-graft following treatment of a traumatic thoracic aortic rupture
    • Idu MM, Reekers JA, Balm R, et al. Collapse of a stent-graft following treatment of a traumatic thoracic aortic rupture. J Endovasc Ther. 2005;12:503-507.
    • (2005) J Endovasc Ther , vol.12 , pp. 503-507
    • Idu, M.M.1    Reekers, J.A.2    Balm, R.3
  • 12
    • 0034994038 scopus 로고    scopus 로고
    • Risk factors for endoleak and the evidence for stent-graft oversizing in patients undergoing endovascular aneurysm repair
    • Mohan IV, Laheij RJF, Harris PL. Risk factors for endoleak and the evidence for stent-graft oversizing in patients undergoing endovascular aneurysm repair. Eur J Vasc Endovasc Surg. 2001;21:344-349.
    • (2001) Eur J Vasc Endovasc Surg , vol.21 , pp. 344-349
    • Mohan, I.V.1    Laheij, R.J.F.2    Harris, P.L.3
  • 13
    • 20444481641 scopus 로고    scopus 로고
    • Extension of dissection in stent-graft treatment of type B aortic dissection: Lessons learned from endovascular experience
    • Fattori R, Lovato L, Buttazzi K, et al. Extension of dissection in stent-graft treatment of type B aortic dissection: lessons learned from endovascular experience. J Endovasc Ther. 2005;12:306-311.
    • (2005) J Endovasc Ther , vol.12 , pp. 306-311
    • Fattori, R.1    Lovato, L.2    Buttazzi, K.3
  • 14
    • 33947608981 scopus 로고    scopus 로고
    • Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture
    • Muhs BE, Balm R, White GH, et al. Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture. J Vasc Surg. 2007;45:655-661.
    • (2007) J Vasc Surg , vol.45 , pp. 655-661
    • Muhs, B.E.1    Balm, R.2    White, G.H.3
  • 15
    • 0034924639 scopus 로고    scopus 로고
    • Pathophysiology of proximal perigraft endoleak following endovascular repair of abdominal aortic aneurysms: A study using a flow model
    • Albertini JN, Macierewicz JA, Yusuf SW, et al. Pathophysiology of proximal perigraft endoleak following endovascular repair of abdominal aortic aneurysms: a study using a flow model. Eur J Vasc Endovasc Surg. 2001;22:53-56.
    • (2001) Eur J Vasc Endovasc Surg , vol.22 , pp. 53-56
    • Albertini, J.N.1    Macierewicz, J.A.2    Yusuf, S.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.