1
-
-
38049033240
-
What is the evidence on the safety and effectiveness of the reuse of medical devices labelled as single-use only?
-
P. Day, "What is the evidence on the safety and effectiveness of the reuse of medical devices labelled as single-use only?" New Zeland Health Technology Assessment, Technical Brief Series vol. 3, 2004.
-
(2004)
New Zeland Health Technology Assessment, Technical Brief Series
, vol.3
-
-
Day, P.1
-
2
-
-
0036899376
-
Can labelled single use devices be reused? An old question in the new era
-
Z. Quian, W. R. Castaneda, "Can labelled single use devices be reused? An old question in the new era", J. Vase. Inter. Radiol, vol. 13, pp. 1183-1186, 2002.
-
(2002)
J. Vase. Inter. Radiol
, vol.13
, pp. 1183-1186
-
-
Quian, Z.1
Castaneda, W.R.2
-
3
-
-
0034932576
-
Risk of infection by reprocessed and resterilized virus-contaminated catheters: An in-vito study
-
D. S. Luijt, J. Schirm, P.H. Savelkoul, A. Hoekstra, "Risk of infection by reprocessed and resterilized virus-contaminated catheters: an in-vito study", Eur. Heart. J., vol. 22, pp. 378-384, 2001.
-
(2001)
Eur. Heart. J
, vol.22
, pp. 378-384
-
-
Luijt, D.S.1
Schirm, J.2
Savelkoul, P.H.3
Hoekstra, A.4
-
4
-
-
0036704429
-
In vitro performance characteristics of reused ablation catheters
-
I. Ayzman, S. R. Dibs, J. Goldberger, R. Passman, A. Kadish, "In vitro performance characteristics of reused ablation catheters", J. Interv. Card. Electrophysiol., vol. 7, pp.53-59, 2002.
-
(2002)
J. Interv. Card. Electrophysiol
, vol.7
, pp. 53-59
-
-
Ayzman, I.1
Dibs, S.R.2
Goldberger, J.3
Passman, R.4
Kadish, A.5
-
5
-
-
0034890767
-
NASPE policy statement. Reprocessing of electrophysiology catheters: Clinical studies, regulations, and recommendations. A report of the NASPE Task Force on Reprocessing of Electrophysiological Catheters
-
B. D. Lindsay, S. P. Kutalek, D. S. Cannom, S. C. Hammill, G. V. Naccarelli, "NASPE policy statement. Reprocessing of electrophysiology catheters: clinical studies, regulations, and recommendations. A report of the NASPE Task Force on Reprocessing of Electrophysiological Catheters", "Pacing Clin. Electrophysiol. Vol 24, pp. 1297-1305, 2001.
-
(2001)
Pacing Clin. Electrophysiol
, vol.24
, pp. 1297-1305
-
-
Lindsay, B.D.1
Kutalek, S.P.2
Cannom, D.S.3
Hammill, S.C.4
Naccarelli, G.V.5
-
6
-
-
0001426203
-
The reuse of single use cardiac catheters: Safety, economical, ethical and legal issues
-
Conseil d'Evaluation des Technologies de la Sante du Quebec
-
Conseil d'Evaluation des Technologies de la Sante du Quebec. "The reuse of single use cardiac catheters: safety, economical, ethical and legal issues", Can. J. Cardiol., vol. 10, pp. 413-421, 1994.
-
(1994)
Can. J. Cardiol
, vol.10
, pp. 413-421
-
-
-
7
-
-
0345320141
-
The safety of reusing ablation catheters with temperature control and the need for a validation protocol and guidelines for reprocessing
-
C. Blomstrom-Lundqvist, "The safety of reusing ablation catheters with temperature control and the need for a validation protocol and guidelines for reprocessing", Pacing Clin. Electrophysiol., vol. 21, pp. 2563-2570, 1998.
-
(1998)
Pacing Clin. Electrophysiol
, vol.21
, pp. 2563-2570
-
-
Blomstrom-Lundqvist, C.1
-
8
-
-
38049017854
-
-
Canadian Hospital Association, last access: 1 October
-
Canadian Hospital Association. "The reuse of single-use medical devices", http://sprojects.mmi.mcgill.ca/heart/carecha2ca.html. (last access: 1 October 2006)
-
(2006)
The reuse of single-use medical devices
-
-
-
9
-
-
0031010667
-
Priority-Setting for Health Technology Assessment. Theoretical Considerations and Practical Approaches
-
C. Henshall, W. Oortwijn, A. Stevens, A. Granados, D. Banta, "Priority-Setting for Health Technology Assessment. Theoretical Considerations and Practical Approaches", Int. J. Technol Assess. Health Care vol. 13, pp. 144-185, 1997.
-
(1997)
Int. J. Technol Assess. Health Care
, vol.13
, pp. 144-185
-
-
Henshall, C.1
Oortwijn, W.2
Stevens, A.3
Granados, A.4
Banta, D.5
-
10
-
-
33947600730
-
Different protocols for decontamination affect cleaning of medical devices. A preliminary electron microscopy analysis
-
F. Tessarolo, I. Caola, M. Fedel, P. Caciagli, G. M. Guarrera, A. Motta, G. Nollo, "Different protocols for decontamination affect cleaning of medical devices. A preliminary electron microscopy analysis", J. Hosp. Infect., vol. 65, pp. 326-333, 2007.
-
(2007)
J. Hosp. Infect
, vol.65
, pp. 326-333
-
-
Tessarolo, F.1
Caola, I.2
Fedel, M.3
Caciagli, P.4
Guarrera, G.M.5
Motta, A.6
Nollo, G.7
-
11
-
-
33846006575
-
Sterility and microbiological assessment in reusing single-use cardiac electrophysiology catheters
-
F. Tessarolo, I. Caola, P. Caciagli, G. M. Guarrera, G. Nollo, "Sterility and microbiological assessment in reusing single-use cardiac electrophysiology catheters", Infect. Control. Hosp. Epidemiol, vol. 27, pp.1385-1392, 2006.
-
(2006)
Infect. Control. Hosp. Epidemiol
, vol.27
, pp. 1385-1392
-
-
Tessarolo, F.1
Caola, I.2
Caciagli, P.3
Guarrera, G.M.4
Nollo, G.5
-
12
-
-
33750034623
-
Efficiency in endotoxins removal by a reprocessing protocol for electrophysiology catheters based on hydrogen peroxide sterilization
-
F. Tessarolo, I. Caola, G. Nollo, R. Antolini, G. M. Guarrera, P. Caciagli, "Efficiency in endotoxins removal by a reprocessing protocol for electrophysiology catheters based on hydrogen peroxide sterilization", J. Hyg. Environ. Health, vol. 209, pp. 557-565, 2006.
-
(2006)
J. Hyg. Environ. Health
, vol.209
, pp. 557-565
-
-
Tessarolo, F.1
Caola, I.2
Nollo, G.3
Antolini, R.4
Guarrera, G.M.5
Caciagli, P.6
-
13
-
-
38049036719
-
Dispositivi medici monouso. Rigenerazione di dispositivi medici e responsabilità. Verso nuovi equilibri fra tecnologia, medicina e diritto
-
U. Izzo, B. Sief, S. Winkler, "Dispositivi medici monouso. Rigenerazione di dispositivi medici e responsabilità. Verso nuovi equilibri fra tecnologia, medicina e diritto", Danno e Responsabilità, vol. 7, pp. 769-803, 2004.
-
(2004)
Danno e Responsabilità
, vol.7
, pp. 769-803
-
-
Izzo, U.1
Sief, B.2
Winkler, S.3
-
14
-
-
38049019361
-
Modello di calcolo della convenienza economica per l'ospedale: Il caso dei cateteri cardiaci rigenerabili vs. i cateteri monouso
-
S. Capri, P. Ferrari, F. Tessarolo, G. M. Guarrera, F. Fontana, G. Nollo, "Modello di calcolo della convenienza economica per l'ospedale: il caso dei cateteri cardiaci rigenerabili vs. i cateteri monouso", Politiche Sanitarie, vol. 6, pp. 188-196, 2005.
-
(2005)
Politiche Sanitarie
, vol.6
, pp. 188-196
-
-
Capri, S.1
Ferrari, P.2
Tessarolo, F.3
Guarrera, G.M.4
Fontana, F.5
Nollo, G.6
-
15
-
-
38049064299
-
Attività dei laboratori di elettrofisiologia italiani nel 2004
-
G. Inama, P. Della Bella, M. Landolina, A. Bonso, C. Pandozi, "Attività dei laboratori di elettrofisiologia italiani nel 2004" Giornale Italiano di Aritmologia e Cardiostimolazione, vol. 4 supp. 1, pp. S1-S15, 2005.
-
(2005)
Giornale Italiano di Aritmologia e Cardiostimolazione
, vol.4
, Issue.SUPP. 1
-
-
Inama, G.1
Della Bella, P.2
Landolina, M.3
Bonso, A.4
Pandozi, C.5
-
16
-
-
4644372560
-
Evaluation and quantification of reprocessing modification in single use devices in interventional cardiology
-
F. Tessarolo, P. Ferrari, G. Nollo, A. Motta, C. Migliaresi, L. Zennaro, A. Rigo, G. M. Guarrera, "Evaluation and quantification of reprocessing modification in single use devices in interventional cardiology", Applied Surface Science, vol. 238, pp. 341-346, 2004.
-
(2004)
Applied Surface Science
, vol.238
, pp. 341-346
-
-
Tessarolo, F.1
Ferrari, P.2
Nollo, G.3
Motta, A.4
Migliaresi, C.5
Zennaro, L.6
Rigo, A.7
Guarrera, G.M.8
-
17
-
-
38049027670
-
Radiofrequency ablation on heart-equivalent phantom. Functionality testing of percutaneous single-use catheter
-
A. Mendez-Vilas ed, Elsevier;
-
F. Tessarolo, P. Ferrari, R. Antolini, G. Nollo, "Radiofrequency ablation on heart-equivalent phantom. Functionality testing of percutaneous single-use catheter", In: A. Mendez-Vilas ed. Recent Advances in Multidisciplinary Applied Physics. Elsevier; 2005. pp. 229-234.
-
(2005)
Recent Advances in Multidisciplinary Applied Physics
, pp. 229-234
-
-
Tessarolo, F.1
Ferrari, P.2
Antolini, R.3
Nollo, G.4
-
18
-
-
4043153397
-
Novel methods for disinfection of prion-contaminated medical devices
-
G. Fichet, E. Comoy, C. Duval, K. Antloga, C. Dehen, A. Charbonnier, G. McDonnell, P. Brown, C. I. Lasmezas, J. P. Deslys, "Novel methods for disinfection of prion-contaminated medical devices", Lancet, vol. 364, pp. 521-526, 2004.
-
(2004)
Lancet
, vol.364
, pp. 521-526
-
-
Fichet, G.1
Comoy, E.2
Duval, C.3
Antloga, K.4
Dehen, C.5
Charbonnier, A.6
McDonnell, G.7
Brown, P.8
Lasmezas, C.I.9
Deslys, J.P.10
|