2
-
-
33947597274
-
Decreto Legislativo 28/09/1990: Norme di protezione dal contagio professionale da HIV nelle strutture sanitarie ed assistenziali pubbliche e private
-
Italian Health Government. Decreto Legislativo 28/09/1990: Norme di protezione dal contagio professionale da HIV nelle strutture sanitarie ed assistenziali pubbliche e private. Gazzetta Ufficiale Repubblica Italiana 235 (1990) 78-80
-
(1990)
Gazzetta Ufficiale Repubblica Italiana
, vol.235
, pp. 78-80
-
-
Italian Health Government1
-
4
-
-
4644372560
-
Evaluation and quantification of reprocessing modification in single use devices in interventional cardiology
-
Tessarolo F., Ferrari P., Bortoluzzi S., et al. Evaluation and quantification of reprocessing modification in single use devices in interventional cardiology. Appl Surf Sci 238 (2004) 341-346
-
(2004)
Appl Surf Sci
, vol.238
, pp. 341-346
-
-
Tessarolo, F.1
Ferrari, P.2
Bortoluzzi, S.3
-
5
-
-
0034579061
-
Plasma-based sterilization: effect on surface and bulk properties and hydrolytic stability of reprocessed polyurethane electrophysiology catheters
-
Lerouge S., Guignot C., Tabrizian M., Ferrier D., Yagoubi N., and Yahia L. Plasma-based sterilization: effect on surface and bulk properties and hydrolytic stability of reprocessed polyurethane electrophysiology catheters. J Biomed Mater Res 15 (2000) 774-782
-
(2000)
J Biomed Mater Res
, vol.15
, pp. 774-782
-
-
Lerouge, S.1
Guignot, C.2
Tabrizian, M.3
Ferrier, D.4
Yagoubi, N.5
Yahia, L.6
-
6
-
-
0037086103
-
Bactericidal efficacy of sterilizing protocol for reused cardiac electrophysiology catheters
-
Grabsch E.A., Grayson M.L., Johnson P.D.R., Yates L.A., Harper R.W., and Smolic J.J. Bactericidal efficacy of sterilizing protocol for reused cardiac electrophysiology catheters. Am J Cardiol 89 (2002) 770-772
-
(2002)
Am J Cardiol
, vol.89
, pp. 770-772
-
-
Grabsch, E.A.1
Grayson, M.L.2
Johnson, P.D.R.3
Yates, L.A.4
Harper, R.W.5
Smolic, J.J.6
-
7
-
-
0344835814
-
Gas-plasma sterilization: relative efficacy of the hydrogen peroxide phase compared with that of the plasma phase
-
Krebs M.C., Bécasse P., Verjat D., and Darbord J.C. Gas-plasma sterilization: relative efficacy of the hydrogen peroxide phase compared with that of the plasma phase. Int J Pharm 160 (1998) 75-81
-
(1998)
Int J Pharm
, vol.160
, pp. 75-81
-
-
Krebs, M.C.1
Bécasse, P.2
Verjat, D.3
Darbord, J.C.4
-
8
-
-
0032213346
-
Safety and efficacy of hydrogen peroxide plasma sterilization for repeated use of electrophysiology catheters
-
Bathina M.N., Mickelsen S., Brooks C., Jaramillo J., Hepton T., and Kusumoto F.M. Safety and efficacy of hydrogen peroxide plasma sterilization for repeated use of electrophysiology catheters. J Am Coll Cardiol 32 (1998) 1384-1388
-
(1998)
J Am Coll Cardiol
, vol.32
, pp. 1384-1388
-
-
Bathina, M.N.1
Mickelsen, S.2
Brooks, C.3
Jaramillo, J.4
Hepton, T.5
Kusumoto, F.M.6
-
9
-
-
33749356335
-
Attualità nella decontaminazione di strumenti chirurgici per la prevenzione delle infezioni occupazionali da HIV, HBV, HCV
-
Agolini G., Clementi M., Lipartiti T., et al. Attualità nella decontaminazione di strumenti chirurgici per la prevenzione delle infezioni occupazionali da HIV, HBV, HCV. Giornale Italiano delle Infezioni Ospedaliere 9 (2002) 90-98
-
(2002)
Giornale Italiano delle Infezioni Ospedaliere
, vol.9
, pp. 90-98
-
-
Agolini, G.1
Clementi, M.2
Lipartiti, T.3
-
11
-
-
0029738949
-
APIC guideline for selection and use of disinfectants. 1994, 1995, and 1996 APIC Guidelines Committee. Association for Professionals in Infection Control and Epidemiology, Inc
-
[Review]
-
Rutala W.A. APIC guideline for selection and use of disinfectants. 1994, 1995, and 1996 APIC Guidelines Committee. Association for Professionals in Infection Control and Epidemiology, Inc. Am J Infect Control 24 (1996) 313-342 [Review]
-
(1996)
Am J Infect Control
, vol.24
, pp. 313-342
-
-
Rutala, W.A.1
-
12
-
-
0001870548
-
Disinfection, sterilization and waste disposal
-
Wenzel B.P. (Ed), Williams and Wilkins, Baltimore
-
Rutala W.A. Disinfection, sterilization and waste disposal. In: Wenzel B.P. (Ed). Prevention and control of nosocominal infection (1987), Williams and Wilkins, Baltimore 257-282
-
(1987)
Prevention and control of nosocominal infection
, pp. 257-282
-
-
Rutala, W.A.1
-
13
-
-
0002825191
-
Chlorine and chlorine releasing compounds
-
Block S.S. (Ed), Lea & Febiger, Philadelphia
-
Dychdala G.R. Chlorine and chlorine releasing compounds. In: Block S.S. (Ed). Disinfection, sterilization and preservation. 4th ed. (1991), Lea & Febiger, Philadelphia 131-151
-
(1991)
Disinfection, sterilization and preservation. 4th ed.
, pp. 131-151
-
-
Dychdala, G.R.1
-
14
-
-
33947608632
-
Effects of chlorine-releasing compounds on medical devices decontamination
-
Tessarolo F., Caola I., Fedel M., Caciagli P., Guarrera G.M., and Nollo G. Effects of chlorine-releasing compounds on medical devices decontamination. J Appl Biomater Biomech 2 (2004) 219
-
(2004)
J Appl Biomater Biomech
, vol.2
, pp. 219
-
-
Tessarolo, F.1
Caola, I.2
Fedel, M.3
Caciagli, P.4
Guarrera, G.M.5
Nollo, G.6
-
15
-
-
1942417548
-
Surface fixation of dried blood by glutaraldehyde and peracetic acid
-
Kampf G., Bloss R., and Martiny H. Surface fixation of dried blood by glutaraldehyde and peracetic acid. J Hosp Infect 57 (2004) 139-143
-
(2004)
J Hosp Infect
, vol.57
, pp. 139-143
-
-
Kampf, G.1
Bloss, R.2
Martiny, H.3
-
16
-
-
0024400980
-
A comparison of hypochlorite and phenolic disinfectants for disinfection of clean and soiled surfaces and blood spillages
-
Bloomfield S.F., and Miller E.A. A comparison of hypochlorite and phenolic disinfectants for disinfection of clean and soiled surfaces and blood spillages. J Hosp Infect 13 (1989) 231-239
-
(1989)
J Hosp Infect
, vol.13
, pp. 231-239
-
-
Bloomfield, S.F.1
Miller, E.A.2
-
17
-
-
0035196544
-
Decontaminated single-use devices: an oxymoron that may be placing patients at risk for cross-contamination
-
Heeg P., Roth K., Reichl R., Cogdill C.P., and Bond W.W. Decontaminated single-use devices: an oxymoron that may be placing patients at risk for cross-contamination. Infect Control Hosp Epidemiol 22 (2001) 542-549
-
(2001)
Infect Control Hosp Epidemiol
, vol.22
, pp. 542-549
-
-
Heeg, P.1
Roth, K.2
Reichl, R.3
Cogdill, C.P.4
Bond, W.W.5
-
18
-
-
0023615585
-
Success of re-use of cardiac electrode catheters
-
Dunnigan A., Roberts C., McNamara M., Benson D.W., and Benditt D.G. Success of re-use of cardiac electrode catheters. Am J Cardiol 60 (1987) 807-810
-
(1987)
Am J Cardiol
, vol.60
, pp. 807-810
-
-
Dunnigan, A.1
Roberts, C.2
McNamara, M.3
Benson, D.W.4
Benditt, D.G.5
-
19
-
-
0029335621
-
Catheter ablation in a less privileged country: the importance of spreading the goods
-
Ruffy R. Catheter ablation in a less privileged country: the importance of spreading the goods. Pacing Clin Electrophysiol 18 (1995) 1463-1464
-
(1995)
Pacing Clin Electrophysiol
, vol.18
, pp. 1463-1464
-
-
Ruffy, R.1
-
20
-
-
0018866702
-
Detection of endotoxin on sterile catheters used for cardiac catheterisation
-
Kundsin R.B., and Walter C.W. Detection of endotoxin on sterile catheters used for cardiac catheterisation. J Clin Microbiol 11 (1980) 209-212
-
(1980)
J Clin Microbiol
, vol.11
, pp. 209-212
-
-
Kundsin, R.B.1
Walter, C.W.2
-
21
-
-
0034108982
-
Effect of gas composition on spore mortality and etching during low-pressure plasma sterilization
-
Lerouge S., Wertheimer M.R., Marchand R., Tabrizian M., and Yahia L. Effect of gas composition on spore mortality and etching during low-pressure plasma sterilization. J Biomed Mater Res 51 (2000) 128-135
-
(2000)
J Biomed Mater Res
, vol.51
, pp. 128-135
-
-
Lerouge, S.1
Wertheimer, M.R.2
Marchand, R.3
Tabrizian, M.4
Yahia, L.5
|