메뉴 건너뛰기




Volumn 44, Issue 11, 2008, Pages 1007-1010

Exploration of three-dimensional biometric measurement of emmetropic adult eye-ball by using magnetic resonance imaging technology

Author keywords

Anthropometry; Dimension; Eye; Magnetic resonance spectroscopy

Indexed keywords

ADOLESCENT; ADULT; ANTHROPOMETRY; ARTICLE; EYE; FEMALE; HISTOLOGY; HUMAN; MALE; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; ANATOMY AND HISTOLOGY; PROCEDURES; YOUNG ADULT;

EID: 57649136852     PISSN: 04124081     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 57649130372 scopus 로고    scopus 로고
    • Clinical visual optics
    • New York: Butterworth
    • Rabbetts RB. Clinical visual optics. 3rd eds. New York: Butterworth, 2007: 15.
    • (2007) 3rd eds , pp. 15
    • Rabbetts, R.B.1
  • 2
    • 57649115858 scopus 로고    scopus 로고
    • Chinese source.
    • Chinese source.
  • 3
    • 57649128108 scopus 로고    scopus 로고
    • Chinese source.
    • Chinese source.
  • 4
    • 0036370742 scopus 로고    scopus 로고
    • Three-dimensional posterior segment ultrasonography: Clinical experiences
    • Kutchoukov B, Lafaut B, De Laey JJ. Three-dimensional posterior segment ultrasonography: clinical experiences. Bull Soc Belge Ophtalmol, 2002,283:51-57.
    • (2002) Bull Soc Belge Ophtalmol , vol.283 , pp. 51-57
    • Kutchoukov, B.1    Lafaut, B.2    De Laey, J.J.3
  • 5
    • 0020066383 scopus 로고    scopus 로고
    • Crow W. Normal in vivo eye dimensions by computed tomography. J Comput Assist Tomogr, 1982, 6:708-710.
    • Crow W. Normal in vivo eye dimensions by computed tomography. J Comput Assist Tomogr, 1982, 6:708-710.
  • 6
    • 0026352955 scopus 로고
    • Magnetic resonance imaging of the human eye in vivo
    • Chen HM. Magnetic resonance imaging of the human eye in vivo. Optom Vis Sci,1991, 68:976-980.
    • (1991) Optom Vis Sci , vol.68 , pp. 976-980
    • Chen, H.M.1
  • 7
    • 0026630437 scopus 로고
    • Shape of the myopia eye as seen with high resolution magnetic resonance imaging
    • Chen HM, Singh OS, Kwong KK, et al Shape of the myopia eye as seen with high resolution magnetic resonance imaging. Optom Vis Sci, 1992,69:698-710.
    • (1992) Optom Vis Sci , vol.69 , pp. 698-710
    • Chen, H.M.1    Singh, O.S.2    Kwong, K.K.3
  • 8
    • 0036769181 scopus 로고    scopus 로고
    • Magetia resonace imaging studies of the volume of the rabbit eye with intravenous mannitol
    • Sawada T, Nakamura J,Nishida Y, et al. Magetia resonace imaging studies of the volume of the rabbit eye with intravenous mannitol. Curr Eye Res, 2002, 25:173-177.
    • (2002) Curr Eye Res , vol.25 , pp. 173-177
    • Sawada, T.1    Nakamura, J.2    Nishida, Y.3
  • 9
    • 0042870142 scopus 로고    scopus 로고
    • MR-based volumetric analysis of small tumor volumes: Accuracy of phantom examination of simulated eye tumors
    • Lemke AJ, Kazi I, Hosten N, et al. MR-based volumetric analysis of small tumor volumes: accuracy of phantom examination of simulated eye tumors. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Vexfahr, 2003,175:958-962.
    • (2003) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Vexfahr , vol.175 , pp. 958-962
    • Lemke, A.J.1    Kazi, I.2    Hosten, N.3
  • 10
    • 57649117688 scopus 로고    scopus 로고
    • Chinese source.
    • Chinese source.
  • 11
    • 57649114401 scopus 로고    scopus 로고
    • Chinese source.
    • Chinese source.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.