메뉴 건너뛰기




Volumn 175, Issue 7, 2003, Pages 958-962

MR-based volumetric analysis of small tumor volumes: Accuracy of phantom examinations of simulated eye tumors;Evaluierung der MR-volumetrie kleiner volumina am beispiel von augentumoren mittels phantomuntersuchungen

Author keywords

MRI; Ocular metastasis; Surface coil; Uveal melanoma; Volumetric measurement

Indexed keywords

GADOLINIUM PENTETATE;

EID: 0042870142     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-40428     Document Type: Article
Times cited : (7)

References (19)
  • 1
    • 0343618648 scopus 로고    scopus 로고
    • Aktuelle therapieaspekte intraokularer tumoren
    • Schueler AO, Bornfeld N. Aktuelle Therapieaspekte intraokularer Tumoren. Der Ophthalmologe 2000; 97: 207-222
    • (2000) Der Ophthalmologe , vol.97 , pp. 207-222
    • Schueler, A.O.1    Bornfeld, N.2
  • 3
    • 0021958329 scopus 로고
    • Accuracy of clinical estimates of tumor dimensions. A clinical-pathologic correlation study of posterior uveal melanomas
    • Augsburger JJ, Gamel JW, Bailey Jr RS, Donoso LA, Gonder JR, Shields JA. Accuracy of clinical estimates of tumor dimensions. A clinical-pathologic correlation study of posterior uveal melanomas. Retina 1985; 5: 26-29
    • (1985) Retina , vol.5 , pp. 26-29
    • Augsburger, J.J.1    Gamel, J.W.2    Bailey R.S., Jr.3    Donoso, L.A.4    Gonder, J.R.5    Shields, J.A.6
  • 6
    • 0018355241 scopus 로고
    • Accurate measurement of liver, kidney, and spleen volume and mass by computerized axial tomography
    • Heymsfield SB, Fulenwider T, Nordlinger B, Barlow R, Sones P, Kutner M. Accurate measurement of liver, kidney, and spleen volume and mass by computerized axial tomography. Ann Intern Med 1979; 90: 185-187
    • (1979) Ann Intern Med , vol.90 , pp. 185-187
    • Heymsfield, S.B.1    Fulenwider, T.2    Nordlinger, B.3    Barlow, R.4    Sones, P.5    Kutner, M.6
  • 7
    • 0028028468 scopus 로고
    • Magnetic resonance measurement of volumes using a phantom: Application to the cardiac ventricles of infants and small children
    • Greenberg SB, Singh GK, Stauffer NR. Magnetic resonance measurement of volumes using a phantom: application to the cardiac ventricles of infants and small children. Invest Radiol 1994; 29: 787-789
    • (1994) Invest Radiol , vol.29 , pp. 787-789
    • Greenberg, S.B.1    Singh, G.K.2    Stauffer, N.R.3
  • 9
    • 0028721967 scopus 로고
    • Mesure du volume hepatique par tomodensitometrie 3D avec correlation anatomique
    • Tudoret L. Mesure du volume hepatique par tomodensitometrie 3D avec correlation anatomique. Ann Radiol Paris 1994; 37: 401-404
    • (1994) Ann Radiol Paris , vol.37 , pp. 401-404
    • Tudoret, L.1
  • 10
    • 0018839841 scopus 로고
    • Diagnostic modalities in choroidal melanoma
    • Char DH, Stone RD, Irvine AR. Diagnostic modalities in choroidal melanoma. Am J Ophthalmol 1980; 89: 223-230
    • (1980) Am J Ophthalmol , vol.89 , pp. 223-230
    • Char, D.H.1    Stone, R.D.2    Irvine, A.R.3
  • 11
    • 0025214319 scopus 로고
    • Ultrasonographic measurement of uveal melanoma thickness: Interobserver variability
    • Char DH, Kroll S, Stone RD. Ultrasonographic measurement of uveal melanoma thickness: interobserver variability. Br J Ophthalmol 1990; 74: 61-66
    • (1990) Br J Ophthalmol , vol.74 , pp. 61-66
    • Char, D.H.1    Kroll, S.2    Stone, R.D.3
  • 13
    • 0033015844 scopus 로고    scopus 로고
    • Uveal melanoma: Correlation of histopathologic and radiologic findings by using thin-section MR imaging with a surface coil
    • Lemke AJ, Hosten N, Bornfeld N, Bechrakis NE, Schüler A, Richter M, Stroszczynski C, Felix R. Uveal melanoma: correlation of histopathologic and radiologic findings by using thin-section MR imaging with a surface coil. Radiology 1999; 210: 775-783
    • (1999) Radiology , vol.210 , pp. 775-783
    • Lemke, A.J.1    Hosten, N.2    Bornfeld, N.3    Bechrakis, N.E.4    Schüler, A.5    Richter, M.6    Stroszczynski, C.7    Felix, R.8
  • 16
    • 0018404258 scopus 로고
    • Abbildungseigenschaften der computertomographie. II. Räumliches auflösungsvermögen, dichteauflösung und partial-volumen-effekt bei kugelförmigen objekten verschiedenen durchmessers
    • Schulz E, Felix R, Lackner K, Bergeder HD, Thurn P. Abbildungseigenschaften der Computertomographie. II. Räumliches Auflösungsvermögen, Dichteauflösung und Partial-Volumen-Effekt bei kugelförmigen Objekten verschiedenen Durchmessers. Fortschr Röntgenstr 1979; 130: 479-486
    • (1979) Fortschr Röntgenstr , vol.130 , pp. 479-486
    • Schulz, E.1    Felix, R.2    Lackner, K.3    Bergeder, H.D.4    Thurn, P.5
  • 18
    • 0025755302 scopus 로고
    • Magnetic resonance imaging of choroidal melanoma with and without gadolinium contrast enhancement
    • Bond JB, Haik BG, Mihara F, Gupta KL. Magnetic resonance imaging of choroidal melanoma with and without gadolinium contrast enhancement. Ophthalmology 1991; 98: 459-466
    • (1991) Ophthalmology , vol.98 , pp. 459-466
    • Bond, J.B.1    Haik, B.G.2    Mihara, F.3    Gupta, K.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.