메뉴 건너뛰기




Volumn 40, Issue 10, 2008, Pages 3673-3678

Is the Affinity Column-Mediated Immunoassay Method Suitable as an Alternative to the Microparticle Enzyme Immunoassay Method as a Blood Tacrolimus Assay?

Author keywords

[No Author keywords available]

Indexed keywords

TACROLIMUS;

EID: 57549088671     PISSN: 00411345     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.transproceed.2008.04.019     Document Type: Article
Times cited : (21)

References (14)
  • 1
    • 0032128129 scopus 로고    scopus 로고
    • Therapeutic drug monitoring of cyclosporin and tacrolimus
    • Ollerich M., Armstrong V.W., Schutz E., et al. Therapeutic drug monitoring of cyclosporin and tacrolimus. Clin Biochem 31 (1998) 309
    • (1998) Clin Biochem , vol.31 , pp. 309
    • Ollerich, M.1    Armstrong, V.W.2    Schutz, E.3
  • 2
    • 0027174992 scopus 로고
    • Cyclosporin clinical pharmacokinetics
    • Fahr A. Cyclosporin clinical pharmacokinetics. Clin Pharmacokinet 24 (1993) 472
    • (1993) Clin Pharmacokinet , vol.24 , pp. 472
    • Fahr, A.1
  • 3
    • 0031781987 scopus 로고    scopus 로고
    • Evaluation of the tacrolimus II microparticle enzyme immunoassay (MEIA II) in liver and renal transplant recipients
    • Cogil J.L., Taylor P.J., Westley I.S., et al. Evaluation of the tacrolimus II microparticle enzyme immunoassay (MEIA II) in liver and renal transplant recipients. Clin Chem 44 (1998) 1942
    • (1998) Clin Chem , vol.44 , pp. 1942
    • Cogil, J.L.1    Taylor, P.J.2    Westley, I.S.3
  • 4
    • 0028204924 scopus 로고
    • Distribution and protein binding of FK506, a potent immunosuppressive macrolide lactone, in human blood and its uptake by erythrocytes
    • Nagase K., Iwasaki K., Nozaki K., et al. Distribution and protein binding of FK506, a potent immunosuppressive macrolide lactone, in human blood and its uptake by erythrocytes. J Pharm Pharmacol 46 (1994) 113
    • (1994) J Pharm Pharmacol , vol.46 , pp. 113
    • Nagase, K.1    Iwasaki, K.2    Nozaki, K.3
  • 5
    • 14544287267 scopus 로고    scopus 로고
    • Low hematocrit and serum albumin concentrations underlie the overestimation of tacrolimus concentrations by microparticle enzyme immunoassay versus liquid chromatography-tandem mass spectrometry
    • Nigel W.B., Christopher E.G., Jemimah E.A., et al. Low hematocrit and serum albumin concentrations underlie the overestimation of tacrolimus concentrations by microparticle enzyme immunoassay versus liquid chromatography-tandem mass spectrometry. Clin Chem 51 (2005) 586
    • (2005) Clin Chem , vol.51 , pp. 586
    • Nigel, W.B.1    Christopher, E.G.2    Jemimah, E.A.3
  • 6
    • 57549093782 scopus 로고    scopus 로고
    • Tacrolimus II: IMx System. Ref 3C10, 34-3782/R7. Abbott Park, Ill Abbott Laboratories
    • Tacrolimus II: IMx System. Ref 3C10, 34-3782/R7. Abbott Park, Ill Abbott Laboratories
  • 7
    • 57549114803 scopus 로고    scopus 로고
    • O'Connor M: Dimension TACR Technical Training, 06/06. Newark, Del: Dade Behring
    • O'Connor M: Dimension TACR Technical Training, 06/06. Newark, Del: Dade Behring
  • 8
    • 34547910644 scopus 로고    scopus 로고
    • Performance of a no-pretreatment tacrolimus assay on the Dade Behring Dimension RxL clinical chemistry analyzer
    • Griffey M.A., Hock K.G., Kilgore D.C., et al. Performance of a no-pretreatment tacrolimus assay on the Dade Behring Dimension RxL clinical chemistry analyzer. Clin Chim Acta 384 (2007) 48
    • (2007) Clin Chim Acta , vol.384 , pp. 48
    • Griffey, M.A.1    Hock, K.G.2    Kilgore, D.C.3
  • 9
    • 0036333913 scopus 로고    scopus 로고
    • Interference of hematocrit in the tacrolimus II microparticle enzyme immunoassay
    • Kuzuya T., Ogura Y., Motegi Y., Moriyama N., et al. Interference of hematocrit in the tacrolimus II microparticle enzyme immunoassay. Ther Drug Monit 24 (2002) 507
    • (2002) Ther Drug Monit , vol.24 , pp. 507
    • Kuzuya, T.1    Ogura, Y.2    Motegi, Y.3    Moriyama, N.4
  • 10
    • 0036689906 scopus 로고    scopus 로고
    • False positive blood tacrolimus concentration in microparticle enzyme immunoassay
    • Homma M., Tomita T., Yuzawa K., et al. False positive blood tacrolimus concentration in microparticle enzyme immunoassay. Biol Pharm Bull 25 (2002) 1119
    • (2002) Biol Pharm Bull , vol.25 , pp. 1119
    • Homma, M.1    Tomita, T.2    Yuzawa, K.3
  • 11
    • 0030984839 scopus 로고    scopus 로고
    • Effect of hematocrit and albumin concentration on hepatic clearance of tacrolimus (FK506) during rabbit liver perfusion
    • Chow F.S., Piekoszewski W., and Jusko W.J. Effect of hematocrit and albumin concentration on hepatic clearance of tacrolimus (FK506) during rabbit liver perfusion. Drug Metab Dispos 25 (1997) 610
    • (1997) Drug Metab Dispos , vol.25 , pp. 610
    • Chow, F.S.1    Piekoszewski, W.2    Jusko, W.J.3
  • 12
    • 0038780593 scopus 로고    scopus 로고
    • Tacrolimus measurement by microparticle enzyme immunoassay II
    • Taylor P.J., and Morris R.G. Tacrolimus measurement by microparticle enzyme immunoassay II. Ther Drug Monit 25 (2003) 259
    • (2003) Ther Drug Monit , vol.25 , pp. 259
    • Taylor, P.J.1    Morris, R.G.2
  • 13
    • 0031781987 scopus 로고    scopus 로고
    • Evaluation of the tacrolimus II microparticle enzyme immunoassay (MEIA II) in liver and renal transplant recipients
    • Cogill J.L., Taylor P.J., Westley I.S., et al. Evaluation of the tacrolimus II microparticle enzyme immunoassay (MEIA II) in liver and renal transplant recipients. Clin Chem 44 (1998) 1942
    • (1998) Clin Chem , vol.44 , pp. 1942
    • Cogill, J.L.1    Taylor, P.J.2    Westley, I.S.3
  • 14
    • 0031648810 scopus 로고    scopus 로고
    • Modified pentamer formation assay for measurement of tacrolimus and its active metabolites:comparison with liquid chromatography-tandem mass spectrometry and microparticle enzyme-linked immunoassay (MEIA-II)
    • Armstrong V.W., Schuetz E., Zhang Q., et al. Modified pentamer formation assay for measurement of tacrolimus and its active metabolites:comparison with liquid chromatography-tandem mass spectrometry and microparticle enzyme-linked immunoassay (MEIA-II). Clin Chem 44 (1998) 2516
    • (1998) Clin Chem , vol.44 , pp. 2516
    • Armstrong, V.W.1    Schuetz, E.2    Zhang, Q.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.