메뉴 건너뛰기




Volumn 44, Issue 9, 1998, Pages 1942-1946

Evaluation of the tacrolimus II microparticle enzyme immunoassay (MEIA II) in liver and renal transplant recipients

Author keywords

[No Author keywords available]

Indexed keywords

ASCOMYCIN; TACROLIMUS;

EID: 0031781987     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/44.9.1942     Document Type: Article
Times cited : (57)

References (26)
  • 2
    • 0027485716 scopus 로고
    • Tacrolimus. A review of its pharmacology, and therapeutic potential in hepatic and renal transplantation
    • Peters DH, Fitton A, Plosker GL, Faulds D. Tacrolimus. A review of its pharmacology, and therapeutic potential in hepatic and renal transplantation. Drugs 1993;46:746-96.
    • (1993) Drugs , vol.46 , pp. 746-796
    • Peters, D.H.1    Fitton, A.2    Plosker, G.L.3    Faulds, D.4
  • 5
    • 0027230926 scopus 로고
    • Improvement and assessment of enzyme-linked immunosorbent assay to detect low FK506 concentrations in plasma or whole blood within 6 hours
    • Wallemacq PE, Firdaous I, Hassoun A. Improvement and assessment of enzyme-linked immunosorbent assay to detect low FK506 concentrations in plasma or whole blood within 6 hours. Clin Chem 1993;39:1045-9.
    • (1993) Clin Chem , vol.39 , pp. 1045-1049
    • Wallemacq, P.E.1    Firdaous, I.2    Hassoun, A.3
  • 6
    • 0028006020 scopus 로고
    • Improved procedures for enzyme immunoassay for tacrolimus (FK506) in whole blood
    • D'ambrosio R, Jusko WJ, Stabler T, Kobayashi M. Improved procedures for enzyme immunoassay for tacrolimus (FK506) in whole blood [Letter]. Clin Chem 1994;40:159-60.
    • (1994) Clin Chem , vol.40 , pp. 159-160
    • D'ambrosio, R.1    Jusko, W.J.2    Stabler, T.3    Kobayashi, M.4
  • 8
    • 0031469727 scopus 로고    scopus 로고
    • Tacrolimus quality assessment
    • Holt DW, Johnston A. Tacrolimus quality assessment [Letter]. Ther Drug Monit 1997;19:243.
    • (1997) Ther Drug Monit , vol.19 , pp. 243
    • Holt, D.W.1    Johnston, A.2
  • 9
    • 0027518214 scopus 로고
    • Isolation, identification, and biological activities of oxidative metabolites of FK506, a potent immunosuppressive macrolide lactone
    • Iwasaki K, Shiraga T, Nagase Z, Tozuka Z, Noda K, Sakuma S, et al. Isolation, identification, and biological activities of oxidative metabolites of FK506, a potent immunosuppressive macrolide lactone. Drug Metab Dispos 1993;21:971-7.
    • (1993) Drug Metab Dispos , vol.21 , pp. 971-977
    • Iwasaki, K.1    Shiraga, T.2    Nagase, Z.3    Tozuka, Z.4    Noda, K.5    Sakuma, S.6
  • 10
    • 0028893714 scopus 로고
    • Further metabolism of FK506 (tacrolimus). Identification and biological activities of the metabolites oxidised at multiple sites of FK506
    • Iwasaki K, Shiraga T, Matsuda H, Nagase K, Tokuma Y, Hata T, et al. Further metabolism of FK506 (tacrolimus). Identification and biological activities of the metabolites oxidised at multiple sites of FK506. Drug Metab Dispos 1995;23:28-34.
    • (1995) Drug Metab Dispos , vol.23 , pp. 28-34
    • Iwasaki, K.1    Shiraga, T.2    Matsuda, H.3    Nagase, K.4    Tokuma, Y.5    Hata, T.6
  • 11
    • 0027945930 scopus 로고
    • Measurement of blood concentrations of FK506 (tacrolimus) and its metabolites in seven liver graft patients after the first dose by h.p.l.c.-MS and microparticle enzyme immunoassay (MEIA)
    • Gonschior A-K, Christians U, Braun F, Winkler M, Linck A, Baumann J, Sewing K-F. Measurement of blood concentrations of FK506 (tacrolimus) and its metabolites in seven liver graft patients after the first dose by h.p.l.c.-MS and microparticle enzyme immunoassay (MEIA). Br J Clin Pharmacol 1994;38:567-71.
    • (1994) Br J Clin Pharmacol , vol.38 , pp. 567-571
    • Gonschior, A.-K.1    Christians, U.2    Braun, F.3    Winkler, M.4    Linck, A.5    Baumann, J.6    Sewing, K.-F.7
  • 13
    • 0028981733 scopus 로고
    • HPLC-microparticle enzyme immunoassay specific for tacrolimus in whole blood of hepatic and renal transplant patients
    • Firdaous I, Hassoun A, Otte JB, Reding R, Squifflet JP, Besse T, Wallemacq PE. HPLC-microparticle enzyme immunoassay specific for tacrolimus in whole blood of hepatic and renal transplant patients. Clin Chem 1995;41:1292-6.
    • (1995) Clin Chem , vol.41 , pp. 1292-1296
    • Firdaous, I.1    Hassoun, A.2    Otte, J.B.3    Reding, R.4    Squifflet, J.P.5    Besse, T.6    Wallemacq, P.E.7
  • 14
    • 0029807891 scopus 로고    scopus 로고
    • Clinical relevance of monitoring tacrolimus: Comparison of microparticle enzyme immunoassay, enzyme-linked immunosorbent assay, and liquid chromatography mass spectrometry in renal transplant recipients converted from cyclosporine to tacrolimus
    • Braun F, Lorf T, Schütz E, Christians U, Grupp C, Sattler B, et al. Clinical relevance of monitoring tacrolimus: comparison of microparticle enzyme immunoassay, enzyme-linked immunosorbent assay, and liquid chromatography mass spectrometry in renal transplant recipients converted from cyclosporine to tacrolimus. Transplant Proc 1996;28:3175-6.
    • (1996) Transplant Proc , vol.28 , pp. 3175-3176
    • Braun, F.1    Lorf, T.2    Schütz, E.3    Christians, U.4    Grupp, C.5    Sattler, B.6
  • 15
    • 0031441675 scopus 로고    scopus 로고
    • High-performance liquid chromatography-tandem mass spectrometry as a reference for analysis of tacrolimus (FK506) to assess two immunoassays in patients with liver and renal transplants
    • Salm P, Taylor PJ, Clark A, Balderson GA, Grygotis A, Norris RLG, et al. High-performance liquid chromatography-tandem mass spectrometry as a reference for analysis of tacrolimus (FK506) to assess two immunoassays in patients with liver and renal transplants. Ther Drug Monit 1997;19:694-700.
    • (1997) Ther Drug Monit , vol.19 , pp. 694-700
    • Salm, P.1    Taylor, P.J.2    Clark, A.3    Balderson, G.A.4    Grygotis, A.5    Norris, R.L.G.6
  • 17
    • 0029156771 scopus 로고
    • Simplified high-performance liquid chromatography-mass spectrometry assay for measurement of tacrolimus and its metabolites and cross-validation with microparticle enzyme immunoassay
    • Gonschior A-K, Christians U, Winkler M, Schiebel HM, Linck A, Sewing K-F. Simplified high-performance liquid chromatography-mass spectrometry assay for measurement of tacrolimus and its metabolites and cross-validation with microparticle enzyme immunoassay. Ther Drug Monit 1995;17:504-10.
    • (1995) Ther Drug Monit , vol.17 , pp. 504-510
    • Gonschior, A.-K.1    Christians, U.2    Winkler, M.3    Schiebel, H.M.4    Linck, A.5    Sewing, K.-F.6
  • 18
    • 0030063763 scopus 로고    scopus 로고
    • Sensitive, specific quantitative analysis of tacrolimus (FK506) in blood by liquid chromatography-electrospray tandem mass spectrometry
    • Taylor PJ, Jones A, Balderson GA, Lynch SV, Norris RLG, Pond SM. Sensitive, specific quantitative analysis of tacrolimus (FK506) in blood by liquid chromatography-electrospray tandem mass spectrometry. Clin Chem 1996;42:279-85.
    • (1996) Clin Chem , vol.42 , pp. 279-285
    • Taylor, P.J.1    Jones, A.2    Balderson, G.A.3    Lynch, S.V.4    Norris, R.L.G.5    Pond, S.M.6
  • 19
    • 0028168171 scopus 로고
    • Reference materials and reference methods in laboratory medicine: A challenge to international cooperation
    • Büttner J. Reference materials and reference methods in laboratory medicine: a challenge to international cooperation. Eur J Clin Chem Clin Biochem 1994;32:571-77.
    • (1994) Eur J Clin Chem Clin Biochem , vol.32 , pp. 571-577
    • Büttner, J.1
  • 20
    • 0030683959 scopus 로고    scopus 로고
    • An improved method for the therapeutic drug monitoring of tacrolimus (FK506) using tandem mass spectrometry [Technical Brief]
    • Taylor PJ, Hogan NS, Lynch SV, Johnson AG, Pond SM. An improved method for the therapeutic drug monitoring of tacrolimus (FK506) using tandem mass spectrometry [Technical Brief]. Clin Chem 1997;43:2189-90.
    • (1997) Clin Chem , vol.43 , pp. 2189-2190
    • Taylor, P.J.1    Hogan, N.S.2    Lynch, S.V.3    Johnson, A.G.4    Pond, S.M.5
  • 21
    • 0021319146 scopus 로고
    • How to improve estimates of imprecision
    • Krouwer JS, Rabinowitz R. How to improve estimates of imprecision. Clin Chem 1984;30:290-2.
    • (1984) Clin Chem , vol.30 , pp. 290-292
    • Krouwer, J.S.1    Rabinowitz, R.2
  • 22
    • 84988175795 scopus 로고
    • Analytical methods validation: Bioavailability, bioequivalence, and pharmacokinetic studies
    • Shah VP, Midha KK, Dighe S, McGilveray IJ, Skelly JP, Yacobi A, et al. Analytical methods validation: bioavailability, bioequivalence, and pharmacokinetic studies. J Pharm Sci 1992;81:309-12.
    • (1992) J Pharm Sci , vol.81 , pp. 309-312
    • Shah, V.P.1    Midha, K.K.2    Dighe, S.3    McGilveray, I.J.4    Skelly, J.P.5    Yacobi, A.6
  • 23
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;i:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 24
    • 0023619772 scopus 로고
    • Physiochemical properties of FK-506, a novel immunosuppressant isolated from Streptomyces tsukubaensis
    • Tanaka H, Kuroda A, Marusawa H, Hashimoto M, Hatanaka H, Kino T, et al. Physiochemical properties of FK-506, a novel immunosuppressant isolated from Streptomyces tsukubaensis. Transplant Proc 1987;5(Suppl 6):11-6.
    • (1987) Transplant Proc , vol.5 , Issue.6 SUPPL. , pp. 11-16
    • Tanaka, H.1    Kuroda, A.2    Marusawa, H.3    Hashimoto, M.4    Hatanaka, H.5    Kino, T.6
  • 26
    • 15444359996 scopus 로고    scopus 로고
    • Abbott Park, IL: Abbott Laboratories
    • Abbott Laboratories. Reagent pack insert for Tacrolimus II. Abbott Park, IL: Abbott Laboratories, 1996:4.
    • (1996) Reagent Pack Insert for Tacrolimus II , pp. 4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.