Volumn 18, Issue 2, 2004, Pages 212-214

Evaluation of real-time PCR data

Author keywords

Amplication; PCR; Quantification; Real time PCR; Validation

Indexed keywords

ACCURACY; ARTICLE; DATA ANALYSIS; MOLECULAR BIOLOGY; REAL TIME POLYMERASE CHAIN REACTION; RELIABILITY; SENSITIVITY AND SPECIFICITY;

EID: 5744232826     PISSN: 0393974X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (99)

References (9)
  • 1
    • 14744306436 scopus 로고
    • Simultaneous amplification and detection of specific DNA sequences
    • Higuchi R, Dollinger G, Walsh PS, et al. Simultaneous amplification and detection of specific DNA sequences. Biotechnology 1992; 10: 413-7.
    • (1992) Biotechnology , vol.10 , pp. 413-417
    • Higuchi, R.1    Dollinger, G.2    Walsh, P.S.3
  • 2
    • 0033775615 scopus 로고    scopus 로고
    • Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays
    • Bustin SA. Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays. J Mol Endocrinol 2000; 25: 169-93.
    • (2000) J. Mol. Endocrinol. , vol.25 , pp. 169-193
    • Bustin, S.A.1
  • 4
    • 17344392308 scopus 로고    scopus 로고
    • A new mathematical model for relative quantification in real-time RT-PCR
    • Pfaffl MW. A new mathematical model for relative quantification in real-time RT-PCR. Nucleic Acids Res 2001; 29: 2002-7.
    • (2001) Nucleic Acids Res. , vol.29 , pp. 2002-2007
    • Pfaffl, M.W.1
  • 5
    • 0037129827 scopus 로고    scopus 로고
    • Accurate normalization of real-time quantitative RT-PCR data by geometric averaging of multiple internal control genes
    • Vandesompele J, De Preter K, Pattyn F, et al. Accurate normalization of real-time quantitative RT-PCR data by geometric averaging of multiple internal control genes. Genome Biol 2002; 3: 0034.
    • (2002) Genome Biol. , vol.3 , pp. 0034
    • Vandesompele, J.1    De Preter, K.2    Pattyn, F.3
  • 7
    • 0002436838 scopus 로고    scopus 로고
    • Quantitative PCR by continuous fluorescence monitoring of a double strand DNA-specific bibding dye
    • Rasmussen R, Morrison T, Herrman M, et al. Quantitative PCR by continuous fluorescence monitoring of a double strand DNA-specific bibding dye. Biochemica 1998; 2: 8-11.
    • (1998) Biochemica , vol.2 , pp. 8-11
    • Rasmussen, R.1    Morrison, T.2    Herrman, M.3
  • 8
    • 0025861818 scopus 로고
    • Detection of specific polymerase chain reaction product by utizing the 5′ to 3′ exonuclease activity of Thermus aquaticus DNA polymerase
    • Holland PM, Abramson RD, Watson R, et al. Detection of specific polymerase chain reaction product by utizing the 5′ to 3′ exonuclease activity of Thermus aquaticus DNA polymerase. Proc Natl Acad Sci USA 1991; 88: 7276-80.
    • (1991) Proc. Natl. Acad. Sci. USA , vol.88 , pp. 7276-7280
    • Holland, P.M.1    Abramson, R.D.2    Watson, R.3
  • 9
    • 3042602665 scopus 로고    scopus 로고
    • Differentiation of acute myeloid leukemia from B- and T-lineage acute lymphoid leukemias by real-time quantitative reverse transcription-PCR of lineage marker mRNA
    • Saussoy P, Vaerman JL, Straetmans N, et al. Differentiation of acute myeloid leukemia from B- and T-lineage acute lymphoid leukemias by real-time quantitative reverse transcription-PCR of lineage marker mRNA. Clin Chem 2004; 50: 1165-73.
    • (2004) Clin. Chem. , vol.50 , pp. 1165-1173
    • Saussoy, P.1    Vaerman, J.L.2    Straetmans, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.