메뉴 건너뛰기




Volumn 68, Issue 8, 2008, Pages 685-691

Different elimination patterns of β-trace protein, β2-microglobulin and cystatin C in haemodialysis, haemodiafiltration and haemofiltration

Author keywords

Beta 2 microglobulin; Cystatins; Dialysis; Haemofiltration; Kidney artificial

Indexed keywords

BETA 2 MICROGLOBULIN; CREATININE; CYSTATIN C; PROTEIN BETA TRACE; UNCLASSIFIED DRUG; UREA; UREMIC TOXIN;

EID: 57349198062     PISSN: 00365513     EISSN: 15027686     Source Type: Journal    
DOI: 10.1080/00365510802047693     Document Type: Article
Times cited : (30)

References (23)
  • 2
    • 0037137562 scopus 로고    scopus 로고
    • Hemodialysis (HEMO) Study Group. Effect of dialysis dose and membrane flux in maintenance hemodialysis
    • Eknoyan G, Beck GJ, Cheung AK, Daugirdas JT, Greene T, Kusek JW, et al. Hemodialysis (HEMO) Study Group. Effect of dialysis dose and membrane flux in maintenance hemodialysis. N Engl J Med 2002;347:2010-19.
    • (2002) N Engl J Med , vol.347 , pp. 2010-2019
    • Eknoyan, G.1    Beck, G.J.2    Cheung, A.K.3    Daugirdas, J.T.4    Greene, T.5    Kusek, J.W.6
  • 3
    • 0037406406 scopus 로고    scopus 로고
    • European Uremic Toxin Work Group (EUTox). Review on uremic toxins: Classification, concentration and interindividual variability
    • Vanholder R, De Smet R, Glorieux G, Argiles A, Baurmeister U, Brunet P, et al. European Uremic Toxin Work Group (EUTox). Review on uremic toxins: classification, concentration and interindividual variability. Kidney Int 2003;63:1934-43.
    • (2003) Kidney Int , vol.63 , pp. 1934-1943
    • Vanholder, R.1    De Smet, R.2    Glorieux, G.3    Argiles, A.4    Baurmeister, U.5    Brunet, P.6
  • 4
    • 0033042913 scopus 로고    scopus 로고
    • Effect of dialysis membranes and middle molecule removal on chronic hemodialysis patient survival
    • Leypoldt JK, Cheung A, Carroll C, Stannard D, Pereira B, Agodoa L, et al. Effect of dialysis membranes and middle molecule removal on chronic hemodialysis patient survival. Am J Kidney Dis 1999;33:349-55.
    • (1999) Am J Kidney Dis , vol.33 , pp. 349-355
    • Leypoldt, J.K.1    Cheung, A.2    Carroll, C.3    Stannard, D.4    Pereira, B.5    Agodoa, L.6
  • 5
    • 0028245396 scopus 로고
    • Determinants of the serum concentrations of low molecular weight proteins in patients on maintenance hemodialysis
    • Kabanda A, Jadoul M, Pochet JM, Lauwerys R, van Ypersele de Strihou C, et al. Determinants of the serum concentrations of low molecular weight proteins in patients on maintenance hemodialysis. Kidney Int 1994;45:1689-96.
    • (1994) Kidney Int , vol.45 , pp. 1689-1696
    • Kabanda, A.1    Jadoul, M.2    Pochet, J.M.3    Lauwerys, R.4    van Ypersele de Strihou, C.5
  • 6
    • 15744382774 scopus 로고    scopus 로고
    • Dialyzer membranes as determinants of the adequacy of dialysis
    • Chelamcharla M, Leypoldt J, Cheung A. Dialyzer membranes as determinants of the adequacy of dialysis. Semin Nephrol 2005;25:81-9.
    • (2005) Semin Nephrol , vol.25 , pp. 81-89
    • Chelamcharla, M.1    Leypoldt, J.2    Cheung, A.3
  • 7
    • 0022396956 scopus 로고
    • Histochemical and immunohistochemical characterization of amyloid associated with chronic hemodialysis as beta 2-microglobulin
    • Shirahama T, Skinner M, Cohen AS, Gejyo F, Arakawa M, Suzuki M, et al. Histochemical and immunohistochemical characterization of amyloid associated with chronic hemodialysis as beta 2-microglobulin. Lab Invest 1985;53:705-9.
    • (1985) Lab Invest , vol.53 , pp. 705-709
    • Shirahama, T.1    Skinner, M.2    Cohen, A.S.3    Gejyo, F.4    Arakawa, M.5    Suzuki, M.6
  • 8
    • 8344252684 scopus 로고    scopus 로고
    • Could plasma cystatin C be useful as a marker of hemodialysis low molecular weight proteins removal?
    • Campo A, Lanfranco G, Gramaglia L, Goia F, Cottino R, Giusto V. Could plasma cystatin C be useful as a marker of hemodialysis low molecular weight proteins removal? Nephron Clin Pract 2004;98:79-82.
    • (2004) Nephron Clin Pract , vol.98 , pp. 79-82
    • Campo, A.1    Lanfranco, G.2    Gramaglia, L.3    Goia, F.4    Cottino, R.5    Giusto, V.6
  • 9
    • 0023698888 scopus 로고    scopus 로고
    • Thysell H, Grubb A, Lindholm T, Ljunggren L, Martensson L. Cystatin C: a new marker of biocompatibility or a good marker for the redistribution of LMW proteins during hemodialysis? ASAIO Trans 1988;34:202-4.
    • Thysell H, Grubb A, Lindholm T, Ljunggren L, Martensson L. Cystatin C: a new marker of biocompatibility or a good marker for the redistribution of LMW proteins during hemodialysis? ASAIO Trans 1988;34:202-4.
  • 10
    • 0015590063 scopus 로고
    • Distribution of serum proteins and beta-trace protein within the nervous system
    • Olsson JE, Link H. Distribution of serum proteins and beta-trace protein within the nervous system. J Neurochem 1973;20:837-46.
    • (1973) J Neurochem , vol.20 , pp. 837-846
    • Olsson, J.E.1    Link, H.2
  • 11
    • 0028173231 scopus 로고
    • Carbohydrate structures of beta-trace protein from human cerebrospinal fluid: Evidence for "brain-type" N-glycosylation
    • Hoffmann A, Nimtz M, Wurster U, Conradt H. Carbohydrate structures of beta-trace protein from human cerebrospinal fluid: evidence for "brain-type" N-glycosylation. J Neurochem 1994;63:2185-96.
    • (1994) J Neurochem , vol.63 , pp. 2185-2196
    • Hoffmann, A.1    Nimtz, M.2    Wurster, U.3    Conradt, H.4
  • 12
    • 0030962207 scopus 로고    scopus 로고
    • Molecular characterization of beta-trace protein in human serum and urine: A potential diagnostic marker for renal diseases
    • Hoffmann A, Nimtz M, Conradt H. Molecular characterization of beta-trace protein in human serum and urine: a potential diagnostic marker for renal diseases. Glycobiology 1997;7:499-506.
    • (1997) Glycobiology , vol.7 , pp. 499-506
    • Hoffmann, A.1    Nimtz, M.2    Conradt, H.3
  • 13
    • 0032940409 scopus 로고    scopus 로고
    • Beta-trace protein in serum: A new marker of glomerular filtration rate in the creatinine-blind range
    • Priem F, Althaus H, Birnbaum M, Sinha P. Conradt H, Jung K. Beta-trace protein in serum: a new marker of glomerular filtration rate in the creatinine-blind range. Clin Chem 1999;45:567-8.
    • (1999) Clin Chem , vol.45 , pp. 567-568
    • Priem, F.1    Althaus, H.2    Birnbaum, M.3    Sinha, P.4    Conradt, H.5    Jung, K.6
  • 14
    • 0028138577 scopus 로고
    • Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric metod, is a better marker than serum creatinine for glomerular filtration rate
    • Kyhse-Andersen J, Schmidt C, Nordin G, Andersson B, Nilsson-Ehle P, Lindström V, et al. Serum cystatin C, determined by a rapid, automated particle-enhanced turbidimetric metod, is a better marker than serum creatinine for glomerular filtration rate. Clin Chem 1994;40:1921-6.
    • (1994) Clin Chem , vol.40 , pp. 1921-1926
    • Kyhse-Andersen, J.1    Schmidt, C.2    Nordin, G.3    Andersson, B.4    Nilsson-Ehle, P.5    Lindström, V.6
  • 15
    • 0030861042 scopus 로고    scopus 로고
    • Reference intervals of the glomerular filtration rate and cell-proliferation markers: Serum cystatin C and serum beta 2-microglobulin/cystatin C-ratio
    • Norlund L, Fex G, Lanke J, von Schenk H, Nilsson JE, Leksell H, et al. Reference intervals of the glomerular filtration rate and cell-proliferation markers: serum cystatin C and serum beta 2-microglobulin/cystatin C-ratio. Scand J Clin Lab Invest 1997;57:463-70.
    • (1997) Scand J Clin Lab Invest , vol.57 , pp. 463-470
    • Norlund, L.1    Fex, G.2    Lanke, J.3    von Schenk, H.4    Nilsson, J.E.5    Leksell, H.6
  • 16
    • 0030035470 scopus 로고    scopus 로고
    • Consensus of a group pf professional societies and diagnostic companies on guidelines for interim reference ranges for 14 proteins in serum based on the standarization against the IFCC/BOR/CAP reference material (CRM 470)
    • Dati F, Schumann G, Thomas L, Aguzzi F, Baudner S, Bienvenu J, et al. Consensus of a group pf professional societies and diagnostic companies on guidelines for interim reference ranges for 14 proteins in serum based on the standarization against the IFCC/BOR/CAP reference material (CRM 470). Eur J Clin Chem Clin Biochem 1996;34:517-20.
    • (1996) Eur J Clin Chem Clin Biochem , vol.34 , pp. 517-520
    • Dati, F.1    Schumann, G.2    Thomas, L.3    Aguzzi, F.4    Baudner, S.5    Bienvenu, J.6
  • 17
    • 33745241637 scopus 로고    scopus 로고
    • Mortality risk for patients receiving hemodiafiltration versus hemodialysis: European results from the DOPPS
    • Canaud B, Bragg-Gresham JL, Marshall MR, Desmeules S, Gillespie BW, Depner T, et al. Mortality risk for patients receiving hemodiafiltration versus hemodialysis: European results from the DOPPS. Kidney Int 2006;69:2087-93.
    • (2006) Kidney Int , vol.69 , pp. 2087-2093
    • Canaud, B.1    Bragg-Gresham, J.L.2    Marshall, M.R.3    Desmeules, S.4    Gillespie, B.W.5    Depner, T.6
  • 18
    • 0034970142 scopus 로고    scopus 로고
    • Second Sardinian Multicentre Study. Predilution haemofiltration - the Second Sardinian Multicentre Study: Comparisons between haemofiltration and haemodialysis during identical Kt/V and session times in a long-term crossover study
    • Altieri P, Sorba G, Bolasco P, Asproni E, Ledebo I, Cossu M, et al. Second Sardinian Multicentre Study. Predilution haemofiltration - the Second Sardinian Multicentre Study: comparisons between haemofiltration and haemodialysis during identical Kt/V and session times in a long-term crossover study. Nephrol Dial Transplant 2001;16:1207-13.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 1207-1213
    • Altieri, P.1    Sorba, G.2    Bolasco, P.3    Asproni, E.4    Ledebo, I.5    Cossu, M.6
  • 19
    • 33645460223 scopus 로고    scopus 로고
    • Serum beta-2 microglobulin levels predict mortality in dialysis patients: Results of the HEMO Study
    • Cheung AK, Rocco MV, Yan G, Leypoldt JK, Levin NW, Greene T, et al. Serum beta-2 microglobulin levels predict mortality in dialysis patients: results of the HEMO Study. J Am Soc Nephrol 2006;17:546-55.
    • (2006) J Am Soc Nephrol , vol.17 , pp. 546-555
    • Cheung, A.K.1    Rocco, M.V.2    Yan, G.3    Leypoldt, J.K.4    Levin, N.W.5    Greene, T.6
  • 20
    • 0345098607 scopus 로고    scopus 로고
    • Effects of high-flux hemodialysis on clinical outcomes: Results of the HEMO study
    • Cheung AK, Levin NW, Greene T, Agodoa L, Bailey J, Beck G, et al. Effects of high-flux hemodialysis on clinical outcomes: results of the HEMO study. J Am Soc Nephrol 2003;14:3251-63.
    • (2003) J Am Soc Nephrol , vol.14 , pp. 3251-3263
    • Cheung, A.K.1    Levin, N.W.2    Greene, T.3    Agodoa, L.4    Bailey, J.5    Beck, G.6
  • 21
    • 0032928363 scopus 로고    scopus 로고
    • Highly elevated levels of prostaglandin D synthase in the serum of patients with renal failure
    • Melegos DN, Grass L, Pierratos A, Diamandis EP. Highly elevated levels of prostaglandin D synthase in the serum of patients with renal failure. Urology 1999;53:32-7.
    • (1999) Urology , vol.53 , pp. 32-37
    • Melegos, D.N.1    Grass, L.2    Pierratos, A.3    Diamandis, E.P.4
  • 22
    • 0026521445 scopus 로고
    • Comparison of hemodialysis and hemodiafiltration: A long-term longitudinal study
    • Kerr P, Argiles A, Flavier J, Canaud B, Mion C. Comparison of hemodialysis and hemodiafiltration: a long-term longitudinal study. Kidney Int 1992;41:1035-40.
    • (1992) Kidney Int , vol.41 , pp. 1035-1040
    • Kerr, P.1    Argiles, A.2    Flavier, J.3    Canaud, B.4    Mion, C.5
  • 23
    • 0036724389 scopus 로고    scopus 로고
    • Osteocalcin and myoglobin removal in on-line hemodiafiltration versus low- and high-flux hemodialysis
    • Maduell F, Navarro V, Cruz MC, Torregrosa E, Garcia D, Simon V, et al. Osteocalcin and myoglobin removal in on-line hemodiafiltration versus low- and high-flux hemodialysis. Am J Kidney Dis 2002;40:582-9.
    • (2002) Am J Kidney Dis , vol.40 , pp. 582-589
    • Maduell, F.1    Navarro, V.2    Cruz, M.C.3    Torregrosa, E.4    Garcia, D.5    Simon, V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.