메뉴 건너뛰기




Volumn 17, Issue 8, 2008, Pages 641-647

Accuracy of impression techniques for implants. Part 1 - Influence of transfer copings surface abrasion

Author keywords

Dental implants; Dental impression materials; Dental impression techniques; Prosthodontics

Indexed keywords

ACRYLIC ACID RESIN; ADHESIVE AGENT; ALUMINUM OXIDE; BIOMEDICAL AND DENTAL MATERIALS; CALCIUM SULFATE; RESIN;

EID: 57349162098     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2008.00308.x     Document Type: Article
Times cited : (25)

References (28)
  • 1
    • 0020805757 scopus 로고
    • Clinical results of osseointegrated implants supporting fixed prostheses in edentulous jaws
    • Adell R : Clinical results of osseointegrated implants supporting fixed prostheses in edentulous jaws. J Prosthet Dent 1983 50 : 251 254
    • (1983) J Prosthet Dent , vol.50 , pp. 251-254
    • Adell, R.1
  • 2
    • 0021952784 scopus 로고
    • Tissue integrated dental prostheses
    • Zarb GA, Zarb FL : Tissue integrated dental prostheses. Quintessence Int 1985 16 : 39 42
    • (1985) Quintessence Int , vol.16 , pp. 39-42
    • Zarb, G.A.1    Zarb, F.L.2
  • 3
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak R : Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983 49 : 843 848
    • (1983) J Prosthet Dent , vol.49 , pp. 843-848
    • Skalak, R.1
  • 4
    • 0035514703 scopus 로고    scopus 로고
    • Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster
    • Wise M : Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster. J Prosthet Dent 2001 86 : 532 538
    • (2001) J Prosthet Dent , vol.86 , pp. 532-538
    • Wise, M.1
  • 5
    • 0027016483 scopus 로고
    • Complex fixed and implant prosthodontics: Making nearly foolproof impressions
    • Christensen GJ : Complex fixed and implant prosthodontics: making nearly foolproof impressions. J Am Dent Assoc 1992 123 : 69 70
    • (1992) J Am Dent Assoc , vol.123 , pp. 69-70
    • Christensen, G.J.1
  • 6
    • 0030089442 scopus 로고    scopus 로고
    • One-step fixed edentulous implant impressions and maxillomandibular jaw relationships: Technical note
    • Dario LJ : One-step fixed edentulous implant impressions and maxillomandibular jaw relationships: technical note. Implant Dent 1996 5 : 23 25
    • (1996) Implant Dent , vol.5 , pp. 23-25
    • Dario, L.J.1
  • 7
    • 0028369033 scopus 로고
    • Segmental framework matrix: Master cast verification, corrected cast guide, and analog transfer template for implant-supported prostheses
    • McCartney JW, Pearson R : Segmental framework matrix: master cast verification, corrected cast guide, and analog transfer template for implant-supported prostheses. J Prosthet Dent 1994 71 : 197 200
    • (1994) J Prosthet Dent , vol.71 , pp. 197-200
    • McCartney, J.W.1    Pearson, R.2
  • 8
    • 84989001629 scopus 로고
    • Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants
    • Waskewickz GA, Ostrowski JS, Parks VJ : Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants. Int J Oral Maxillofac Implants 1994 9 : 405 411
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 405-411
    • Waskewickz, G.A.1    Ostrowski, J.S.2    Parks, V.J.3
  • 9
    • 0034220444 scopus 로고    scopus 로고
    • Comparison of the transfer precision of three different impression materials in combination with transfer caps for the Frialit-2 system
    • Lorenzoni M, Pertl C, Penkner K, et al : Comparison of the transfer precision of three different impression materials in combination with transfer caps for the Frialit-2 system. J Oral Rehabil 2000 27 : 629 638
    • (2000) J Oral Rehabil , vol.27 , pp. 629-638
    • Lorenzoni, M.1    Pertl, C.2    Penkner, K.3    Al, E.4
  • 10
    • 0034186663 scopus 로고    scopus 로고
    • In vitro comparison of master cast accuracy for single-tooth implant replacement
    • Vigolo P, Majzoub Z, Cordioli G : In vitro comparison of master cast accuracy for single-tooth implant replacement. J Prosthet Dent 2000 83 : 562 566
    • (2000) J Prosthet Dent , vol.83 , pp. 562-566
    • Vigolo, P.1    Majzoub, Z.2    Cordioli, G.3
  • 11
    • 0038727298 scopus 로고    scopus 로고
    • Evaluation of the accuracy of three techniques used for multiple implant abutment impressions
    • Vigolo P, Majzoub Z, Cordioli G : Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 2003 89 : 186 192
    • (2003) J Prosthet Dent , vol.89 , pp. 186-192
    • Vigolo, P.1    Majzoub, Z.2    Cordioli, G.3
  • 13
    • 11444261183 scopus 로고    scopus 로고
    • Evaluation of transfer impressions for osseointegrated implants at various angulations
    • Assunção WG, Gennari-Filho H, Zaniquelli O : Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 2004 13 : 358 366
    • (2004) Implant Dent , vol.13 , pp. 358-366
    • Assunção, W.G.1    Gennari-Filho, H.2    Zaniquelli, O.3
  • 14
    • 43949157843 scopus 로고
    • An accurate impression method for implant prosthesis fabrication
    • Shiau J, Chen L, Wu C : An accurate impression method for implant prosthesis fabrication. J Prosthet Dent 1994 72 : 23 25
    • (1994) J Prosthet Dent , vol.72 , pp. 23-25
    • Shiau, J.1    Chen, L.2    Wu, C.3
  • 17
    • 2342418510 scopus 로고    scopus 로고
    • Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments
    • Naconecy MM, Teixeira ER, Shikai RS, et al : Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004 19 : 192 198
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 192-198
    • Naconecy, M.M.1    Teixeira, E.R.2    Shikai, R.S.3    Al, E.4
  • 18
    • 0025622921 scopus 로고
    • The accuracy of implant master casts constructed from transfer impressions
    • Humphries RM, Yaman P, Bloem TJ : The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990 5 : 331 336
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 331-336
    • Humphries, R.M.1    Yaman, P.2    Bloem, T.J.3
  • 19
    • 0027615809 scopus 로고
    • A comparative analysis of the accuracy of implant transfer techniques
    • Hsu CC, Millstein PL, Stein RS : A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 1993 69 : 588 593
    • (1993) J Prosthet Dent , vol.69 , pp. 588-593
    • Hsu, C.C.1    Millstein, P.L.2    Stein, R.S.3
  • 20
    • 0034185646 scopus 로고    scopus 로고
    • Evaluation of impression accuracy for osseointegrated implant supported superstructures
    • Herbst D, Nel JC, Driessen CH, et al : Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 2000 83 : 555 561
    • (2000) J Prosthet Dent , vol.83 , pp. 555-561
    • Herbst, D.1    Nel, J.C.2    Driessen, C.H.3    Al, E.4
  • 21
    • 0025412492 scopus 로고
    • An evaluation of impression techniques for osseointegrated implants
    • Spector MR, Donovan TE, Nicholls JI : An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990 63 : 444 447
    • (1990) J Prosthet Dent , vol.63 , pp. 444-447
    • Spector, M.R.1    Donovan, T.E.2    Nicholls, J.I.3
  • 22
    • 0027597615 scopus 로고
    • Evaluation of three impression techniques for osseointegrated oral implants
    • Inturregui JA, Aquilino SA, Ryther JS, et al : Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 1993 69 : 503 509
    • (1993) J Prosthet Dent , vol.69 , pp. 503-509
    • Inturregui, J.A.1    Aquilino, S.A.2    Ryther, J.S.3    Al, E.4
  • 23
    • 0142111323 scopus 로고
    • The accuracy of three implant impression techniques: A three-dimensional analysis
    • Phillips KM, Nicholls JI, Ma T, et al : The accuracy of three implant impression techniques: a three-dimensional analysis. Int J Oral Maxillofac Implants 1994 9 : 533 540
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 533-540
    • Phillips, K.M.1    Nicholls, J.I.2    Ma, T.3    Al, E.4
  • 24
    • 0030641241 scopus 로고    scopus 로고
    • A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system
    • Burawi G, Houston F, Byrne D, et al : A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 1997 77 : 68 75
    • (1997) J Prosthet Dent , vol.77 , pp. 68-75
    • Burawi, G.1    Houston, F.2    Byrne, D.3    Al, E.4
  • 25
    • 0027031321 scopus 로고
    • Comparison of impression techniques for a two-implant 15-degree divergent model
    • Carr AB : Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implants 1992 7 : 468 475
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 468-475
    • Carr, A.B.1
  • 26
    • 0018967162 scopus 로고
    • Linear dimensional changes in elastic impression materials
    • Marcinak CF, Young FA, Draughn RA, et al : Linear dimensional changes in elastic impression materials. J Dent Res 1980 59 : 1152 1155
    • (1980) J Dent Res , vol.59 , pp. 1152-1155
    • Marcinak, C.F.1    Young, F.A.2    Draughn, R.A.3    Al, E.4
  • 27
    • 33645312706 scopus 로고    scopus 로고
    • Radiographic angles in hallux valgus: Differences between measurements made manually and with a computerized program
    • Pique-Vidal C, Maled-Garcia I, Arabi-Moreno J, et al : Radiographic angles in hallux valgus: differences between measurements made manually and with a computerized program. Foot Ankle Int 2006 27 : 175 180
    • (2006) Foot Ankle Int , vol.27 , pp. 175-180
    • Pique-Vidal, C.1    Maled-Garcia, I.2    Arabi-Moreno, J.3    Al, E.4
  • 28
    • 3042611430 scopus 로고    scopus 로고
    • Comparison of apical transportation between ProFile and ProTaper NiTi rotary instruments
    • Iqbal MK, Firic S, Tulcan J, et al : Comparison of apical transportation between ProFile and ProTaper NiTi rotary instruments. Int Endod J 2004 37 : 359 364
    • (2004) Int Endod J , vol.37 , pp. 359-364
    • Iqbal, M.K.1    Firic, S.2    Tulcan, J.3    Al, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.