메뉴 건너뛰기




Volumn 27, Issue 7, 2000, Pages 629-638

Comparison of the transfer precision of three different impression materials in combination with transfer caps for the Frialit®-2 system

Author keywords

[No Author keywords available]

Indexed keywords

ALGINIC ACID; ALUMINUM OXIDE; BIOMEDICAL AND DENTAL MATERIALS; POLYVINYL DERIVATIVE; RESIN; SILOXANE; VINYL POLYSILOXANE;

EID: 0034220444     PISSN: 0305182X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2842.2000.00594.x     Document Type: Review
Times cited : (65)

References (25)
  • 2
    • 0030641241 scopus 로고    scopus 로고
    • A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-lock implant system
    • BURAWI, G., HOUSTON, F., BYRNE, D. & CLAFFEY, N. (1997) A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-lock implant system. Journal of Prosthetic Dentistry, 77, 68.
    • (1997) Journal of Prosthetic Dentistry , vol.77 , pp. 68
    • Burawi, G.1    Houston, F.2    Byrne, D.3    Claffey, N.4
  • 4
    • 0027031321 scopus 로고
    • Comparison of impression techniques for a two-implant 15-degree divergent model
    • CARR, A.B. (1992) Comparison of impression techniques for a two-implant 15-degree divergent model. International Journal of Oral and Maxillofacial Implants, 7, 468.
    • (1992) International Journal of Oral and Maxillofacial Implants , vol.7 , pp. 468
    • Carr, A.B.1
  • 5
    • 0026955658 scopus 로고
    • Polyvinyl siloxan impression materials: A review of properties and techniques
    • CHEE, W.W. & DONOVAN, T.E. (1992) Polyvinyl siloxan impression materials: a review of properties and techniques. Journal of Prosthetic Dentistry, 68, 728.
    • (1992) Journal of Prosthetic Dentistry , vol.68 , pp. 728
    • Chee, W.W.1    Donovan, T.E.2
  • 8
    • 0027615809 scopus 로고
    • A comparative analysis of the accuracy of implant transfer techniques
    • HSU, C.C., MILLSTEIN, P.L. & STEIN, R.S. (1993) A comparative analysis of the accuracy of implant transfer techniques. Journal of Prosthetic Dentistry, 69, 588.
    • (1993) Journal of Prosthetic Dentistry , vol.69 , pp. 588
    • Hsu, C.C.1    Millstein, P.L.2    Stein, R.S.3
  • 10
    • 0026862039 scopus 로고
    • Accuracy of one-step versus two-step putty wash addition silicone impression technique
    • HUNG, S., PURK, J., TIRA, D. & EICK, J. (1992) Accuracy of one-step versus two-step putty wash addition silicone impression technique. Journal of Prosthetic Dentistry, 67, 583.
    • (1992) Journal of Prosthetic Dentistry , vol.67 , pp. 583
    • Hung, S.1    Purk, J.2    Tira, D.3    Eick, J.4
  • 11
    • 0029396278 scopus 로고
    • Comparison of the dimensional accuracy of one- And two-step techniques with the use of putty/wash addition silicone impression materials
    • IDRIS, B., HOUSTON, F. & CLAFFEY, N. (1995) Comparison of the dimensional accuracy of one- and two-step techniques with the use of putty/wash addition silicone impression materials. Journal of Prosthetic Dentistry, 74, 535.
    • (1995) Journal of Prosthetic Dentistry , vol.74 , pp. 535
    • Idris, B.1    Houston, F.2    Claffey, N.3
  • 15
    • 0027622922 scopus 로고
    • Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials
    • LIOU, A.D., NICHOLLS, J.I., YOUDELIS, R.A. & BRUDVIK, J.S. (1993) Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. International Journal of Prosthodontics, 6, 377.
    • (1993) International Journal of Prosthodontics , vol.6 , pp. 377
    • Liou, A.D.1    Nicholls, J.I.2    Youdelis, R.A.3    Brudvik, J.S.4
  • 18
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseo-integrated prostheses
    • SKALAK, R. (1983) Biomechanical considerations in osseo-integrated prostheses. Journal of Prosthetic Dentistry, 49, 843.
    • (1983) Journal of Prosthetic Dentistry , vol.49 , pp. 843
    • Skalak, R.1
  • 19
    • 0025412492 scopus 로고
    • An evaluation of impression techniques for osseo-integrated implants
    • SPECTOR, M., DONOVAN, T. & NICHOLLS, J. (1990) An evaluation of impression techniques for osseo-integrated implants. Journal of Prosthetic Dentistry, 63, 444.
    • (1990) Journal of Prosthetic Dentistry , vol.63 , pp. 444
    • Spector, M.1    Donovan, T.2    Nicholls, J.3
  • 20
    • 0028382084 scopus 로고
    • Pathogenesis of implant failures
    • TONETTI, M. & SCHMID, J. (1994) Pathogenesis of implant failures. Periodontology 2000, 4, 127.
    • (1994) Periodontology 2000 , vol.4 , pp. 127
    • Tonetti, M.1    Schmid, J.2
  • 21
    • 0021508448 scopus 로고
    • Dimensional stability of elastomeric impression materials in custom-made and stock trays
    • VALDERHAUG, J. & FLØYSTRAND, F. (1984) Dimensional stability of elastomeric impression materials in custom-made and stock trays. Journal of Prosthetic Dentistry, 52, 514.
    • (1984) Journal of Prosthetic Dentistry , vol.52 , pp. 514
    • Valderhaug, J.1    Fløystrand, F.2
  • 23
    • 0025473926 scopus 로고
    • Bestimmung der Abformgenauigkeiten verschiedener Elastomere mit Hilfe einer 3D- Koordinatenmeßmaschine
    • WICHMANN, M., BORCHERS, L. & LIMMROTH, E. (1990) Bestimmung der Abformgenauigkeiten verschiedener Elastomere mit Hilfe einer 3D- Koordinatenmeßmaschine. Deutsche Zahnärztliche Zeitung, 45, 499.
    • (1990) Deutsche Zahnärztliche Zeitung , vol.45 , pp. 499
    • Wichmann, M.1    Borchers, L.2    Limmroth, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.