1
-
-
0017698765
-
Mass fragmentography of creatinine proposed as a reference method
-
Björkhem, I., Blomstrand, R., and Öhman, G. 1977. Mass fragmentography of creatinine proposed as a reference method. Clin. Chem., 23: 2114-2121.
-
(1977)
Clin. Chem
, vol.23
, pp. 2114-2121
-
-
Björkhem, I.1
Blomstrand, R.2
Öhman, G.3
-
2
-
-
35648993029
-
Preparation of creatinine standard stock solution
-
Dai, X.H. 2007. Preparation of creatinine standard stock solution. Anal. Lett., 40: 2946-2948.
-
(2007)
Anal. Lett
, vol.40
, pp. 2946-2948
-
-
Dai, X.H.1
-
3
-
-
34548852204
-
Determination of serum uric acid using high-performance liquid chromatography (HPLC)/ isotope dilution mass spectrometry (ID-MS) as a candidate reference method
-
Dai, X.H., Fang, X., Zhang, C.M., Xu, R.F., and Xu, B. 2007. Determination of serum uric acid using high-performance liquid chromatography (HPLC)/ isotope dilution mass spectrometry (ID-MS) as a candidate reference method. J. Chromatogr. B, 857: 287-295.
-
(2007)
J. Chromatogr. B
, vol.857
, pp. 287-295
-
-
Dai, X.H.1
Fang, X.2
Zhang, C.M.3
Xu, R.F.4
Xu, B.5
-
4
-
-
0028829445
-
Three routine methods for serum cortisol evaluated by comparison with an isotope dilution gas chromatography-mass spectrometry method
-
De Brabandere, V.I., Veronique, I., Thienpont, L.M., Stöckl, D., and De Leenheer, A.P. 1995. Three routine methods for serum cortisol evaluated by comparison with an isotope dilution gas chromatography-mass spectrometry method. Clin. Chem., 41: 1781-1783.
-
(1995)
Clin. Chem
, vol.41
, pp. 1781-1783
-
-
De Brabandere, V.I.1
Veronique, I.2
Thienpont, L.M.3
Stöckl, D.4
De Leenheer, A.P.5
-
5
-
-
0020540170
-
External quality assessment of assays for cortisol in plasma: Use of target data obtained by gas chromatography/mass spectrometry
-
Gaskell, S.J., Collins, C.J., Thorne, G.C., and Groom, G.V. 1983. External quality assessment of assays for cortisol in plasma: Use of target data obtained by gas chromatography/mass spectrometry. Clin. Chem., 29: 862-867.
-
(1983)
Clin. Chem
, vol.29
, pp. 862-867
-
-
Gaskell, S.J.1
Collins, C.J.2
Thorne, G.C.3
Groom, G.V.4
-
6
-
-
0016174096
-
Creatinine metabolism in humans with decreased renal function: Creatinine deficit
-
Jones, J.D. and Burnett, P.C. 1974. Creatinine metabolism in humans with decreased renal function: Creatinine deficit. Clin. Chem., 20: 1204-1212.
-
(1974)
Clin. Chem
, vol.20
, pp. 1204-1212
-
-
Jones, J.D.1
Burnett, P.C.2
-
7
-
-
0018091953
-
Negligible effect of bilirubin on serum creatinine measurement by the kinetic Jaffe method
-
Knight, D.R. and Trainer, T.D. 1978. Negligible effect of bilirubin on serum creatinine measurement by the kinetic Jaffe method. Clin. Chem., 24: 1851-1852.
-
(1978)
Clin. Chem
, vol.24
, pp. 1851-1852
-
-
Knight, D.R.1
Trainer, T.D.2
-
8
-
-
0024826314
-
Assessment of renal function by serum creatinine and creatinine clearance: Glomerular filtration rate estimated by four procedures
-
Lente, F.V. and Suit, P. 1989. Assessment of renal function by serum creatinine and creatinine clearance: Glomerular filtration rate estimated by four procedures. Clin. Chem., 35: 2326-2330.
-
(1989)
Clin. Chem
, vol.35
, pp. 2326-2330
-
-
Lente, F.V.1
Suit, P.2
-
9
-
-
84949508848
-
-
2nd Ed, Hoboken, N.J, John Wiley and Sons
-
March, R.E. and Todd, J.F.J. 2005. Quadrupole Ion Trap Mass Spectrometry. 2nd Ed., Hoboken, N.J.: John Wiley and Sons, 1-33.
-
(2005)
Quadrupole Ion Trap Mass Spectrometry
, pp. 1-33
-
-
March, R.E.1
Todd, J.F.J.2
-
11
-
-
84945018793
-
Measurement of creatinine in human serum by isotope dilution mass spectrometry
-
Siekmann, L. 1985. Measurement of creatinine in human serum by isotope dilution mass spectrometry. J. Clin. Chem. Clin. Biochem., 23: 137-144.
-
(1985)
J. Clin. Chem. Clin. Biochem
, vol.23
, pp. 137-144
-
-
Siekmann, L.1
-
12
-
-
84946380079
-
Determination of cortisol in human plasma by isotope dilution-mass spectrometry: Definitive methods in clinical chemistry
-
Siekmann, L. and Breur, H. 1982. Determination of cortisol in human plasma by isotope dilution-mass spectrometry: Definitive methods in clinical chemistry. J. Clin. Chem. Clin. Biochem., 20: 883-892.
-
(1982)
J. Clin. Chem. Clin. Biochem
, vol.20
, pp. 883-892
-
-
Siekmann, L.1
Breur, H.2
-
13
-
-
0029804718
-
Calibration for isotope dilution mass spectrometry - Ddescription of an alternative to the bracketing procedure
-
Thienpont, L.M., van Nieuwenhove, B., Stockl, D., and de Leenheer, A.P. 1996. Calibration for isotope dilution mass spectrometry - Ddescription of an alternative to the bracketing procedure. J. Mass. Spectrom., 31: 1119-1125.
-
(1996)
J. Mass. Spectrom
, vol.31
, pp. 1119-1125
-
-
Thienpont, L.M.1
van Nieuwenhove, B.2
Stockl, D.3
de Leenheer, A.P.4
-
14
-
-
0030058559
-
Candidate reference method for determining serum cortisol based on isotope dilution-gas chromatography/mass spectrometry using heptafluorobutyrilation as derivatization method
-
Thienpont, L.M., Veronique, I., De Brabandere, V.I., Stöckl, D., and De Leenheer, A.P. 1996. Candidate reference method for determining serum cortisol based on isotope dilution-gas chromatography/mass spectrometry using heptafluorobutyrilation as derivatization method. Anal. Biochem., 234: 204-209.
-
(1996)
Anal. Biochem
, vol.234
, pp. 204-209
-
-
Thienpont, L.M.1
Veronique, I.2
De Brabandere, V.I.3
Stöckl, D.4
De Leenheer, A.P.5
-
15
-
-
0020608182
-
An automated dry-slide enzymatic method evaluated for measurement of creatinine in serum
-
Toffaletti, J., Blosser, N., Hall, T., Smith, S., and Tompkins, D. 1983. An automated dry-slide enzymatic method evaluated for measurement of creatinine in serum. Clin. Chem., 29: 684-687.
-
(1983)
Clin. Chem
, vol.29
, pp. 684-687
-
-
Toffaletti, J.1
Blosser, N.2
Hall, T.3
Smith, S.4
Tompkins, D.5
|