-
1
-
-
0025806883
-
Elastography: A quantitative method for imaging the elasticity in biological tissues
-
J. Ophir, E. I. Cespedes, H. Ponnekanti, Y. Yazdi, and X. Li, "Elastography: A quantitative method for imaging the elasticity in biological tissues," Ultrason. Imaging, vol. 13, no. 2, pp. 111-134, 1991.
-
(1991)
Ultrason. Imaging
, vol.13
, Issue.2
, pp. 111-134
-
-
Ophir, J.1
Cespedes, E.I.2
Ponnekanti, H.3
Yazdi, Y.4
Li, X.5
-
2
-
-
0034104646
-
The pathophysiology of acute coronary syndromes
-
M. J. Davies, "The pathophysiology of acute coronary syndromes," Heart, vol. 83, no. 3, pp. 361-366, 2000.
-
(2000)
Heart
, vol.83
, Issue.3
, pp. 361-366
-
-
Davies, M.J.1
-
3
-
-
0029090411
-
Coronary plaque disruption
-
E. Falk, P. K. Shah, and V. Fuster, "Coronary plaque disruption," Circulation, vol. 92, no. 3, pp. 657-671, 1995.
-
(1995)
Circulation
, vol.92
, Issue.3
, pp. 657-671
-
-
Falk, E.1
Shah, P.K.2
Fuster, V.3
-
4
-
-
3042621700
-
Terminology for high-risk and vulnerable coronary artery plaques
-
J. A. Schaar, J. E. Muller, E. Falk, R. Virmani, V. Fuster, P. W. Serruys, A. Colombo, C. Stefanadis, S. Ward Casscells, P. R. Moreno, A. Maseri, and A. F. W. van der Steen, "Terminology for high-risk and vulnerable coronary artery plaques," Eur. Heart J., vol. 25, no. 12, pp. 1077-1082, 2004.
-
(2004)
Eur. Heart J
, vol.25
, Issue.12
, pp. 1077-1082
-
-
Schaar, J.A.1
Muller, J.E.2
Falk, E.3
Virmani, R.4
Fuster, V.5
Serruys, P.W.6
Colombo, A.7
Stefanadis, C.8
Ward Casscells, S.9
Moreno, P.R.10
Maseri, A.11
van der Steen, A.F.W.12
-
5
-
-
0030825419
-
Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms
-
C. L. de Korte, E. I. Cespedes, A. F. W. van der Steen, and C. T. Lancee, "Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms," Ultrasound Med. Biol., vol. 23, no. 5, pp. 735-746, 1997.
-
(1997)
Ultrasound Med. Biol
, vol.23
, Issue.5
, pp. 735-746
-
-
de Korte, C.L.1
Cespedes, E.I.2
van der Steen, A.F.W.3
Lancee, C.T.4
-
6
-
-
0343729905
-
Intraluminal ultrasonic palpation: Assessment of local and crosssectional tissue stiffness
-
E. I. Cespedes, C. L. de Korte, and A. F. W. van der Steen, "Intraluminal ultrasonic palpation: Assessment of local and crosssectional tissue stiffness," Ultrasound Med. Biol., vol. 26, no. 3, pp. 385-396, 2000.
-
(2000)
Ultrasound Med. Biol
, vol.26
, Issue.3
, pp. 385-396
-
-
Cespedes, E.I.1
de Korte, C.L.2
van der Steen, A.F.W.3
-
7
-
-
0036992957
-
Real time intravascular ultrasound elastography with rotating single element transducer
-
C. Perrey, T. Neumann, W. Bojara, S. Holt, and H. Ermert, "Real time intravascular ultrasound elastography with rotating single element transducer," in Proc. IEEE Ultrason. Symp., 2002, pp. 1913-1916.
-
(2002)
Proc. IEEE Ultrason. Symp
, pp. 1913-1916
-
-
Perrey, C.1
Neumann, T.2
Bojara, W.3
Holt, S.4
Ermert, H.5
-
8
-
-
0344844424
-
Characterizing vulnerable plaque features with intravascular elastography
-
J. A. Schaar, C. L. De Korte, F. Mastik, C. Strijder, G. Pasterkamp, E. Boersma, P. W. Serruys, and A. F. van der Steen, "Characterizing vulnerable plaque features with intravascular elastography," Circulation, vol. 108, no. 21, pp. 2636-2641, 2003.
-
(2003)
Circulation
, vol.108
, Issue.21
, pp. 2636-2641
-
-
Schaar, J.A.1
De Korte, C.L.2
Mastik, F.3
Strijder, C.4
Pasterkamp, G.5
Boersma, E.6
Serruys, P.W.7
van der Steen, A.F.8
-
9
-
-
11844265861
-
On the potential of the Lagrangian speckle model estimator to characterize atherosclerotic plaques in endovascular elastography: In vitro experiments using an excised human carotid artery
-
R. L. Maurice, E. Brusseau, G. Finet, and G. Cloutier, "On the potential of the Lagrangian speckle model estimator to characterize atherosclerotic plaques in endovascular elastography: In vitro experiments using an excised human carotid artery," Ultrasound Med. Biol., vol. 31, no. 1, pp. 85-91, 2005.
-
(2005)
Ultrasound Med. Biol
, vol.31
, Issue.1
, pp. 85-91
-
-
Maurice, R.L.1
Brusseau, E.2
Finet, G.3
Cloutier, G.4
-
10
-
-
2942579077
-
Incidence of high-strain patterns in human coronary arteries: Assessment with three-dimensional intravascular palpography and correlation with clinical presentation
-
J. A. Schaar, E. Regar, F. Mastik, E. P. McFadden, F. Saia, C. Disco, C. L. de Korte, P. J. de Feyter, A. F. W. van der Steen, and P. W. Serruys, "Incidence of high-strain patterns in human coronary arteries: Assessment with three-dimensional intravascular palpography and correlation with clinical presentation," Circulation, vol. 109, no. 22, pp. 2716-2719, 2004.
-
(2004)
Circulation
, vol.109
, Issue.22
, pp. 2716-2719
-
-
Schaar, J.A.1
Regar, E.2
Mastik, F.3
McFadden, E.P.4
Saia, F.5
Disco, C.6
de Korte, C.L.7
de Feyter, P.J.8
van der Steen, A.F.W.9
Serruys, P.W.10
-
11
-
-
0030734228
-
A theoretical framework for performance characterization of elastography: The strain filter
-
T. Varghese and J. Ophir, "A theoretical framework for performance characterization of elastography: The strain filter," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, no. 1, pp. 164-172, 1997.
-
(1997)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.44
, Issue.1
, pp. 164-172
-
-
Varghese, T.1
Ophir, J.2
-
12
-
-
0029272023
-
A fundamental limit on delay estimation using partially correlated speckle signals
-
W. F. Walker and G. E. Trahey, "A fundamental limit on delay estimation using partially correlated speckle signals," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 42, no. 2, pp. 301-308, 1995.
-
(1995)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.42
, Issue.2
, pp. 301-308
-
-
Walker, W.F.1
Trahey, G.E.2
-
13
-
-
0032785966
-
Speckle tracking methods for ultrasonic elasticity imaging using shorttime correlation
-
M. A. Lubinski, S. Y. Emelianov, and M. O'Donnell, "Speckle tracking methods for ultrasonic elasticity imaging using shorttime correlation," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 46, no. 1, pp. 82-96, 1999.
-
(1999)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.46
, Issue.1
, pp. 82-96
-
-
Lubinski, M.A.1
Emelianov, S.Y.2
O'Donnell, M.3
-
14
-
-
0027177373
-
Reduction of image noise in elastography
-
I. Cespedes and J. Ophir, "Reduction of image noise in elastography," Ultrason. Imaging, vol. 15, no. 2, pp. 89-102, 1993.
-
(1993)
Ultrason. Imaging
, vol.15
, Issue.2
, pp. 89-102
-
-
Cespedes, I.1
Ophir, J.2
-
15
-
-
0031056017
-
Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography
-
S. K. Alam and J. Ophir, "Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography," Ultrasound Med. Biol., vol. 23, no. 1, pp. 95-105, 1997.
-
(1997)
Ultrasound Med. Biol
, vol.23
, Issue.1
, pp. 95-105
-
-
Alam, S.K.1
Ophir, J.2
-
16
-
-
0030736520
-
Enhancement of echo-signal correlation in elastography using temporal stretching
-
T. Varghese and J. Ophir, "Enhancement of echo-signal correlation in elastography using temporal stretching," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, no. 1, pp. 173-180, 1997.
-
(1997)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.44
, Issue.1
, pp. 173-180
-
-
Varghese, T.1
Ophir, J.2
-
17
-
-
0030361402
-
Crossambiguity and wavelet processing in ultrasound elasticity imaging
-
E. I. Cespedes, C. de Korte, and A. van der Steen, "Crossambiguity and wavelet processing in ultrasound elasticity imaging," in Proc. IEEE Ultrason. Symp., 1996, pp. 1135-1138.
-
(1996)
Proc. IEEE Ultrason. Symp
, pp. 1135-1138
-
-
Cespedes, E.I.1
de Korte, C.2
van der Steen, A.3
-
18
-
-
0032014719
-
An adaptive strain estimator for elastography
-
S. K. Alam, J. Ophir, and E. E. Konofagou, "An adaptive strain estimator for elastography," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 45, no. 2, pp. 461-472, 1998.
-
(1998)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.45
, Issue.2
, pp. 461-472
-
-
Alam, S.K.1
Ophir, J.2
Konofagou, E.E.3
-
19
-
-
8844242553
-
Theoretical derivation of SNR , CNR and spatial resolution for a local adaptive strain estimator for elastography
-
S. Srinivasan, J. Ophir, and S. K. Alam, "Theoretical derivation of SNR , CNR and spatial resolution for a local adaptive strain estimator for elastography," Ultrasound Med. Biol., vol. 30, no. 9, pp. 1185-1197, 2004.
-
(2004)
Ultrasound Med. Biol
, vol.30
, Issue.9
, pp. 1185-1197
-
-
Srinivasan, S.1
Ophir, J.2
Alam, S.K.3
-
20
-
-
0032820432
-
Power spectral strain estimators in elastography
-
E. E. Konofagou, T. Varghese, J. Ophir, and S. K. Alam, "Power spectral strain estimators in elastography," Ultrasound Med. Biol., vol. 25, no. 7, pp. 1115-1129, 1999.
-
(1999)
Ultrasound Med. Biol
, vol.25
, Issue.7
, pp. 1115-1129
-
-
Konofagou, E.E.1
Varghese, T.2
Ophir, J.3
Alam, S.K.4
-
21
-
-
0034508886
-
Direct strain estimation in elastography using spectral cross-correlation
-
T. Varghese, E. E. Konofagou, J. Ophir, S. K. Alam, and M. Bilgen, "Direct strain estimation in elastography using spectral cross-correlation," Ultrasound Med. Biol., vol. 26, no. 9, pp. 1525-1537, 2000.
-
(2000)
Ultrasound Med. Biol
, vol.26
, Issue.9
, pp. 1525-1537
-
-
Varghese, T.1
Konofagou, E.E.2
Ophir, J.3
Alam, S.K.4
Bilgen, M.5
-
22
-
-
0032694295
-
Axial movement of the intravascular ultrasound probe during the cardiac cycle: Implications for three-dimensional reconstruction and measurements of coronary dimensions
-
A. Arbab-Zadeh, A. N. DeMaria, W. F. Penny, R. J. Russo, B. J. Kimura, and V. Bhargava, "Axial movement of the intravascular ultrasound probe during the cardiac cycle: Implications for three-dimensional reconstruction and measurements of coronary dimensions," Am. Heart J., vol. 138, no. 5, pt. 1, pp. 865-872, 1999.
-
(1999)
Am. Heart J
, vol.138
, Issue.5 PART. 1
, pp. 865-872
-
-
Arbab-Zadeh, A.1
DeMaria, A.N.2
Penny, W.F.3
Russo, R.J.4
Kimura, B.J.5
Bhargava, V.6
-
23
-
-
0028343438
-
Speckle motion artifact under tissue rotation
-
F. Kallel, M. Bertrand, and J. Meunier, "Speckle motion artifact under tissue rotation," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 41, no. 1, pp. 105-122, 1994.
-
(1994)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.41
, Issue.1
, pp. 105-122
-
-
Kallel, F.1
Bertrand, M.2
Meunier, J.3
-
24
-
-
33746682435
-
Towards pointwise motion tracking in echocardiographic image sequences - Comparing the reliability of different features for speckle tracking
-
W. Yu, P. Yan, A. J. Sinusas, K. Thiele, and J. S. Duncan, "Towards pointwise motion tracking in echocardiographic image sequences - Comparing the reliability of different features for speckle tracking," Med. Image Anal., vol. 10, no. 4, pp. 495-508, 2006.
-
(2006)
Med. Image Anal
, vol.10
, Issue.4
, pp. 495-508
-
-
Yu, W.1
Yan, P.2
Sinusas, A.J.3
Thiele, K.4
Duncan, J.S.5
-
25
-
-
0030471104
-
Strain imaging of coronary arteries with intraluminal ultrasound: Experiments on an inhomogenous phantom
-
B. M. Shapo, J. R. Crowe, R. Erkamp, S. Y. Emelianov, M. J. Eberle, and M. O'Donnell, "Strain imaging of coronary arteries with intraluminal ultrasound: Experiments on an inhomogenous phantom," Ultrason. Imaging, vol. 18, no. 3, pp. 173-191, 1996.
-
(1996)
Ultrason. Imaging
, vol.18
, Issue.3
, pp. 173-191
-
-
Shapo, B.M.1
Crowe, J.R.2
Erkamp, R.3
Emelianov, S.Y.4
Eberle, M.J.5
O'Donnell, M.6
-
26
-
-
0032663956
-
Influence of catheter position on estimated strain in intravascular elastography
-
C. L. de Korte, E. I. Cespedes, and A. F. W. van der Steen, "Influence of catheter position on estimated strain in intravascular elastography," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 46, no. 3, pp. 616-625, 1999.
-
(1999)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.46
, Issue.3
, pp. 616-625
-
-
de Korte, C.L.1
Cespedes, E.I.2
van der Steen, A.F.W.3
-
27
-
-
0035731417
-
A modified synthetic aperture focusing technique for the correction of geometric artifacts in intravascular ultrasound elastography
-
C. Perrey, W. Wilkening, B. Brendel, and H. Ermert, "A modified synthetic aperture focusing technique for the correction of geometric artifacts in intravascular ultrasound elastography," in Proc. IEEE Ultrason. Symp., 2001, pp. 1585-1588.
-
(2001)
Proc. IEEE Ultrason. Symp
, pp. 1585-1588
-
-
Perrey, C.1
Wilkening, W.2
Brendel, B.3
Ermert, H.4
-
28
-
-
27744440945
-
A general solution for catheter position effects for strain estimation in intravascular elastography
-
H. Shi, Q. Chen, and T. Varghese, "A general solution for catheter position effects for strain estimation in intravascular elastography," Ultrasound Med. Biol., vol. 31, no. 11, pp. 1509-1526, 2005.
-
(2005)
Ultrasound Med. Biol
, vol.31
, Issue.11
, pp. 1509-1526
-
-
Shi, H.1
Chen, Q.2
Varghese, T.3
-
29
-
-
23844444674
-
Motion artifact reduction for IVUS-based thermal strain imaging
-
Y. Shi, F. Javier de Ana, S. J. Chetcuti, and M. O'Donnell, "Motion artifact reduction for IVUS-based thermal strain imaging," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 52, no. 8, pp. 1312-1319, 2005.
-
(2005)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.52
, Issue.8
, pp. 1312-1319
-
-
Shi, Y.1
Javier de Ana, F.2
Chetcuti, S.J.3
O'Donnell, M.4
-
30
-
-
0035660753
-
Advancing intravascular ultrasonic palpation toward clinical applications
-
M. M. Doyley, F. Mastik, C. L. de Korte, S. G. Carlier, E. I. Cespedes, P. W. Serruys, N. Bom, and A. F. W. van der Steen, "Advancing intravascular ultrasonic palpation toward clinical applications," Ultrasound Med. Biol., vol. 27, no. 11, pp. 1471-1480, 2001.
-
(2001)
Ultrasound Med. Biol
, vol.27
, Issue.11
, pp. 1471-1480
-
-
Doyley, M.M.1
Mastik, F.2
de Korte, C.L.3
Carlier, S.G.4
Cespedes, E.I.5
Serruys, P.W.6
Bom, N.7
van der Steen, A.F.W.8
-
31
-
-
33747205463
-
Motion compensation for intravascular ultrasound palpography
-
K. Y. Leung, R. A. Baldewsing, F. Mastik, J. A. Schaar, A. Gisolf, and A. F. W. van der Steen, "Motion compensation for intravascular ultrasound palpography," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 53, no. 7, pp. 1269-1280, 2006.
-
(2006)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.53
, Issue.7
, pp. 1269-1280
-
-
Leung, K.Y.1
Baldewsing, R.A.2
Mastik, F.3
Schaar, J.A.4
Gisolf, A.5
van der Steen, A.F.W.6
-
32
-
-
44449165569
-
Accuracy in prediction of catheter rotation in IVUS with feature-based optical flow - A phantom study
-
M. G. Danilouchkine, F. Mastik, and A. F. W. van der Steen, "Accuracy in prediction of catheter rotation in IVUS with feature-based optical flow - A phantom study," IEEE Trans. Inform. Technol. Biomed., vol. 12, no. 3, pp. 356-365, 2008.
-
(2008)
IEEE Trans. Inform. Technol. Biomed
, vol.12
, Issue.3
, pp. 356-365
-
-
Danilouchkine, M.G.1
Mastik, F.2
van der Steen, A.F.W.3
-
33
-
-
0036522194
-
Morphological and mechanical information of coronary arteries obtained with intravascular elastography: Feasibility study in vivo
-
C. L. de Korte, S. G. Carlier, F. Mastik, M. M. Doyley, A. F. W. van der Steen, P. W. Serruys, and N. Bom, "Morphological and mechanical information of coronary arteries obtained with intravascular elastography: Feasibility study in vivo," Eur. Heart J., vol. 23, no. 5, pp. 405-413, 2002.
-
(2002)
Eur. Heart J
, vol.23
, Issue.5
, pp. 405-413
-
-
de Korte, C.L.1
Carlier, S.G.2
Mastik, F.3
Doyley, M.M.4
van der Steen, A.F.W.5
Serruys, P.W.6
Bom, N.7
-
34
-
-
0027559559
-
Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes - A review
-
I. A. Hein and W. D. O'Brien, "Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes - A review," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 40, no. 2, pp. 84-102, 1993.
-
(1993)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.40
, Issue.2
, pp. 84-102
-
-
Hein, I.A.1
O'Brien, W.D.2
-
35
-
-
0026123398
-
A novel method for angle independent ultrasonic-imaging of blood-flow and tissue motion
-
L. N. Bohs and G. E. Trahey, "A novel method for angle independent ultrasonic-imaging of blood-flow and tissue motion," IEEE Trans. Biomed. Eng., vol. 38, no. 3, pp. 280-286, 1991.
-
(1991)
IEEE Trans. Biomed. Eng
, vol.38
, Issue.3
, pp. 280-286
-
-
Bohs, L.N.1
Trahey, G.E.2
-
36
-
-
0032033822
-
Intravascular ultrasound elastography in human arteries: Initial experience in vitro
-
C. L. de Korte, A. F. W. van der Steen, E. I. Cespedes, and G. Pasterkamp, "Intravascular ultrasound elastography in human arteries: Initial experience in vitro," Ultrasound Med. Biol., vol. 24, no. 3, pp. 401-408, 1998.
-
(1998)
Ultrasound Med. Biol
, vol.24
, Issue.3
, pp. 401-408
-
-
de Korte, C.L.1
van der Steen, A.F.W.2
Cespedes, E.I.3
Pasterkamp, G.4
-
37
-
-
12444319938
-
Carotid artery wall motion estimated from b-mode ultrasound using region tracking and block matching
-
S. Golemati, A. Sassano, M. J. Lever, A. A. Bharath, S. Dhanjil, and A. N. Nicolaides, "Carotid artery wall motion estimated from b-mode ultrasound using region tracking and block matching," Ultrasound Med. Biol., vol. 29, no. 3, pp. 387-399, 2003.
-
(2003)
Ultrasound Med. Biol
, vol.29
, Issue.3
, pp. 387-399
-
-
Golemati, S.1
Sassano, A.2
Lever, M.J.3
Bharath, A.A.4
Dhanjil, S.5
Nicolaides, A.N.6
-
38
-
-
4444228914
-
Improving motion estimation by accounting for local image distortion
-
V. Behar, D. Adam, P. Lysyansky, and Z. Friedman, "Improving motion estimation by accounting for local image distortion," Ultrasonics, vol. 43, no. 1, pp. 57-65, 2004.
-
(2004)
Ultrasonics
, vol.43
, Issue.1
, pp. 57-65
-
-
Behar, V.1
Adam, D.2
Lysyansky, P.3
Friedman, Z.4
-
39
-
-
0030107866
-
Displacement and strain imaging of coronary arteries with intraluminal ultrasound
-
B. M. Shapo, J. R. Crowe, A. R. Skovoroda, M. J. Eberle, N. A. Cohn, and M. O'Donnell, "Displacement and strain imaging of coronary arteries with intraluminal ultrasound," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 43, no. 2, pp. 234-246, 1996.
-
(1996)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.43
, Issue.2
, pp. 234-246
-
-
Shapo, B.M.1
Crowe, J.R.2
Skovoroda, A.R.3
Eberle, M.J.4
Cohn, N.A.5
O'Donnell, M.6
-
40
-
-
0034154679
-
Angle matching in intravascular elastography
-
C. R. M. Janssen, C. L. de Korte, M. S. van der Heiden, C. P. Wapenaar, and A. F. W. van der Steen, "Angle matching in intravascular elastography," Ultrasonics, vol. 38, no. 1-8, pp. 417-423, 2000.
-
(2000)
Ultrasonics
, vol.38
, Issue.1-8
, pp. 417-423
-
-
Janssen, C.R.M.1
de Korte, C.L.2
van der Heiden, M.S.3
Wapenaar, C.P.4
van der Steen, A.F.W.5
-
41
-
-
0038714256
-
A comparison of the performance of time-delay estimators in medical ultrasound
-
F. Viola and W. F. Walker, "A comparison of the performance of time-delay estimators in medical ultrasound," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 50, no. 4, pp. 392-401, 2003.
-
(2003)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.50
, Issue.4
, pp. 392-401
-
-
Viola, F.1
Walker, W.F.2
-
42
-
-
29244433732
-
Comparison of shift estimation strategies in spectral elastography
-
K. Hoyt, F. Forsberg, and J. Ophir, "Comparison of shift estimation strategies in spectral elastography," Ultrasonics, vol. 44, no. 1, pp. 99-108, 2006.
-
(2006)
Ultrasonics
, vol.44
, Issue.1
, pp. 99-108
-
-
Hoyt, K.1
Forsberg, F.2
Ophir, J.3
-
43
-
-
1442324441
-
Musculoskeletal motion flow fields using hierarchical variable-sized block matching in ultrasonographic video sequences
-
J. D. Revell, M. Mirmehdi, and D. S. McNally, "Musculoskeletal motion flow fields using hierarchical variable-sized block matching in ultrasonographic video sequences," J. Biomech., vol. 37, no. 4, pp. 511-522, 2004.
-
(2004)
J. Biomech
, vol.37
, Issue.4
, pp. 511-522
-
-
Revell, J.D.1
Mirmehdi, M.2
McNally, D.S.3
-
44
-
-
0032762144
-
An overlap invariant entropy measure of 3D medical image alignment
-
C. Studholme, D. L. G. Hill, and D. J. Hawkes, "An overlap invariant entropy measure of 3D medical image alignment," Pattern Recognit., vol. 32, no. 1, pp. 71-86, 1999.
-
(1999)
Pattern Recognit
, vol.32
, Issue.1
, pp. 71-86
-
-
Studholme, C.1
Hill, D.L.G.2
Hawkes, D.J.3
-
45
-
-
0042433431
-
Comparison of time-domain displacement estimators for twodimensional RF tracking
-
S. Langeland, J. D'Hooge, H. Torp, B. Bijnens, and P. Suetens, "Comparison of time-domain displacement estimators for twodimensional RF tracking," Ultrasound Med. Biol., vol. 29, no. 8, pp. 1177-1186, 2003.
-
(2003)
Ultrasound Med. Biol
, vol.29
, Issue.8
, pp. 1177-1186
-
-
Langeland, S.1
D'Hooge, J.2
Torp, H.3
Bijnens, B.4
Suetens, P.5
-
46
-
-
0019597413
-
Determining optical flow
-
B. Horn and B. Schunck, "Determining optical flow," Artif. Intell., vol. 17, no. 1-3, pp. 185-203, 1981.
-
(1981)
Artif. Intell
, vol.17
, Issue.1-3
, pp. 185-203
-
-
Horn, B.1
Schunck, B.2
-
47
-
-
0029772518
-
The robust estimation of multiple motions: Parametric and piecewise-smooth flow fields
-
M. J. Black and P. Anandan, "The robust estimation of multiple motions: Parametric and piecewise-smooth flow fields," Comput. Vis. Image Underst., vol. 63, no. 1, pp. 75-104, 1996.
-
(1996)
Comput. Vis. Image Underst
, vol.63
, Issue.1
, pp. 75-104
-
-
Black, M.J.1
Anandan, P.2
-
48
-
-
0030111001
-
Evaluation of differential optical flow techniques on synthesized echo images
-
P. Baraldi, A. Sarti, C. Lamberti, A. Prandini, and F. Sgallari, "Evaluation of differential optical flow techniques on synthesized echo images," IEEE Trans. Biomed. Eng., vol. 43, no. 3, pp. 259-272, 1996.
-
(1996)
IEEE Trans. Biomed. Eng
, vol.43
, Issue.3
, pp. 259-272
-
-
Baraldi, P.1
Sarti, A.2
Lamberti, C.3
Prandini, A.4
Sgallari, F.5
-
49
-
-
30744440614
-
Tracking of left ventricular long axis from real-time threedimensional echocardiography using optical flow techniques
-
F. Veronesi, C. Corsi, E. G. Caiani, A. Sarti, and C. Lamberti, "Tracking of left ventricular long axis from real-time threedimensional echocardiography using optical flow techniques," IEEE Trans. Inf. Technol. Biomed., vol. 10, no. 1, pp. 174-181, 2006.
-
(2006)
IEEE Trans. Inf. Technol. Biomed
, vol.10
, Issue.1
, pp. 174-181
-
-
Veronesi, F.1
Corsi, C.2
Caiani, E.G.3
Sarti, A.4
Lamberti, C.5
-
51
-
-
0035209263
-
Ultrasonic properties of random media under uniaxial loading
-
M. F. Insana, T. J. Hall, P. Chaturvedi, and C. Kargel, "Ultrasonic properties of random media under uniaxial loading," J. Acoust. Soc. Am., vol. 110, no. 6, pp. 3243-3251, 2001.
-
(2001)
J. Acoust. Soc. Am
, vol.110
, Issue.6
, pp. 3243-3251
-
-
Insana, M.F.1
Hall, T.J.2
Chaturvedi, P.3
Kargel, C.4
-
52
-
-
67649320193
-
Quantification of vessel wall motion in IVUS pull-backs with dense optical flow
-
M. G. Danilouchkine, F. Mastik, and A. F. W. van der Steen, "Quantification of vessel wall motion in IVUS pull-backs with dense optical flow," in Proc. 2nd MICCAI Workshop on Comp. Vis. for Intravascular and Intracardiac Imaging, 2008, pp. 8-13.
-
(2008)
Proc. 2nd MICCAI Workshop on Comp. Vis. for Intravascular and Intracardiac Imaging
, pp. 8-13
-
-
Danilouchkine, M.G.1
Mastik, F.2
van der Steen, A.F.W.3
-
53
-
-
0029210315
-
Robust computation of optical-flow in a multiscale differential framework
-
J. Weber and J. Malik, "Robust computation of optical-flow in a multiscale differential framework," Int. J. Comput. Vis., vol. 14, no. 1, pp. 67-81, 1995.
-
(1995)
Int. J. Comput. Vis
, vol.14
, Issue.1
, pp. 67-81
-
-
Weber, J.1
Malik, J.2
-
54
-
-
0002836012
-
An iterative image registration technique with an application to stereo vision
-
B. Lucas and T. Kanade, "An iterative image registration technique with an application to stereo vision," in Proc. DARPA Image Understanding Workshop, 1981, pp. 121-130.
-
(1981)
Proc. DARPA Image Understanding Workshop
, pp. 121-130
-
-
Lucas, B.1
Kanade, T.2
-
56
-
-
0028423506
-
General intensity transformations and differential invariants
-
L. M. J. Florack, B. M. ter Haar Romeny, J. J. Koenderink, and M. A. Viergever, "General intensity transformations and differential invariants," J. Math. Imaging Vis., vol. 4, no. 2, pp. 171-187, 1994.
-
(1994)
J. Math. Imaging Vis
, vol.4
, Issue.2
, pp. 171-187
-
-
Florack, L.M.J.1
ter Haar Romeny, B.M.2
Koenderink, J.J.3
Viergever, M.A.4
-
57
-
-
84976670463
-
The computation of optical flow
-
S. S. Beauchemin and J. L. Barron, "The computation of optical flow," ACM Comput. Surv., vol. 27, no. 3, pp. 433-467, 1995.
-
(1995)
ACM Comput. Surv
, vol.27
, Issue.3
, pp. 433-467
-
-
Beauchemin, S.S.1
Barron, J.L.2
-
58
-
-
0031021607
-
Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity
-
K. C. Chu and B. K. Rutt, "Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity," Magn. Reson. Med., vol. 37, no. 2, pp. 314-319, 1997.
-
(1997)
Magn. Reson. Med
, vol.37
, Issue.2
, pp. 314-319
-
-
Chu, K.C.1
Rutt, B.K.2
-
59
-
-
0029324838
-
Ultrasonic texture motion analysis: Theory and simulation
-
J. Meunier and M. Bertrand, "Ultrasonic texture motion analysis: Theory and simulation," IEEE Trans. Med. Imaging, vol. 14, no. 2, pp. 223-240, 1995.
-
(1995)
IEEE Trans. Med. Imaging
, vol.14
, Issue.2
, pp. 223-240
-
-
Meunier, J.1
Bertrand, M.2
-
60
-
-
0029797499
-
The effect of variations in transducer position and sound speed in intravascular ultrasound: A theoretical study
-
R. S. Thompson and L. S. Wilson, "The effect of variations in transducer position and sound speed in intravascular ultrasound: A theoretical study," Ultrasound Med. Biol., vol. 22, no. 6, pp. 719-734, 1996.
-
(1996)
Ultrasound Med. Biol
, vol.22
, Issue.6
, pp. 719-734
-
-
Thompson, R.S.1
Wilson, L.S.2
-
61
-
-
33644917419
-
-
C. A. van Mieghem, E. P. McFadden, P. J. de Feyter, N. Bruining, J. A. Schaar, N. R. Mollet, F. Cademartiri, D. Goedhart, S. de Winter, G. R. Granillo, M. Valgimigli, F. Mastik, A. F. W. van der Steen, W. J. van der Giessen, G. Sianos, B. Backx, M. A. Morel, G. A. van Es, A. Zalewski, and P. W. Serruys, Noninvasive detection of subclinical coronary atherosclerosis coupled with assessment of changes in plaque characteristics using novel invasive imaging modalities: The integrated biomarker and imaging study (IBIS), J. Am. Coll. Cardiol., 47, no. 6, pp. 1134-1142, 2006.
-
C. A. van Mieghem, E. P. McFadden, P. J. de Feyter, N. Bruining, J. A. Schaar, N. R. Mollet, F. Cademartiri, D. Goedhart, S. de Winter, G. R. Granillo, M. Valgimigli, F. Mastik, A. F. W. van der Steen, W. J. van der Giessen, G. Sianos, B. Backx, M. A. Morel, G. A. van Es, A. Zalewski, and P. W. Serruys, "Noninvasive detection of subclinical coronary atherosclerosis coupled with assessment of changes in plaque characteristics using novel invasive imaging modalities: The integrated biomarker and imaging study (IBIS)," J. Am. Coll. Cardiol., vol. 47, no. 6, pp. 1134-1142, 2006.
-
-
-
-
62
-
-
0032691666
-
Echo decorrelation from displacement gradients in elasticity and velocity estimation
-
E. I. Cespedes, C. L. de Korte, and A. F. W. van der Steen, "Echo decorrelation from displacement gradients in elasticity and velocity estimation," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 46, no. 4, pp. 791-801, 1999.
-
(1999)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.46
, Issue.4
, pp. 791-801
-
-
Cespedes, E.I.1
de Korte, C.L.2
van der Steen, A.F.W.3
-
63
-
-
0033302585
-
The influence of through-plane motion on left ventricular volumes measured by magnetic resonance imaging: Implications for image acquisition and analysis
-
J. T. Marcus, M. J. Gotte, L. K. DeWaal, M. R. Stam, R. J. van der Geest, R. M. Heethaar, and A. C. Van Rossum, "The influence of through-plane motion on left ventricular volumes measured by magnetic resonance imaging: Implications for image acquisition and analysis," J. Cardiovasc. Magn. Reson., vol. 1, no. 1, pp. 1-6, 1999.
-
(1999)
J. Cardiovasc. Magn. Reson
, vol.1
, Issue.1
, pp. 1-6
-
-
Marcus, J.T.1
Gotte, M.J.2
DeWaal, L.K.3
Stam, M.R.4
van der Geest, R.J.5
Heethaar, R.M.6
Van Rossum, A.C.7
-
64
-
-
17744399502
-
Threedimensional palpography of human coronary arteries. Ex vivo validation and inpatient evaluation
-
J. A. Schaar, C. L. de Korte, F. Mastik, L. C. A. van Damme, R. Krams, P. W. Serruys, and A. F. W. van der Steen, "Threedimensional palpography of human coronary arteries. Ex vivo validation and inpatient evaluation," Herz, vol. 30, no. 2, pp. 125-133, 2005.
-
(2005)
Herz
, vol.30
, Issue.2
, pp. 125-133
-
-
Schaar, J.A.1
de Korte, C.L.2
Mastik, F.3
van Damme, L.C.A.4
Krams, R.5
Serruys, P.W.6
van der Steen, A.F.W.7
-
65
-
-
44449153871
-
An inverse method for imaging the local elasticity of atherosclerotic coronary plaques
-
R. A. Baldewsing, M. G. Danilouchkine, F. Mastik, J. A. Schaar, P. W. Serruys, and A. F. W. van der Steen, "An inverse method for imaging the local elasticity of atherosclerotic coronary plaques," IEEE Trans. Inform. Technol. Biomed., vol. 12, no. 3, pp. 277-289, 2008.
-
(2008)
IEEE Trans. Inform. Technol. Biomed
, vol.12
, Issue.3
, pp. 277-289
-
-
Baldewsing, R.A.1
Danilouchkine, M.G.2
Mastik, F.3
Schaar, J.A.4
Serruys, P.W.5
van der Steen, A.F.W.6
-
66
-
-
84862362359
-
Model-based reconstructive elasticity imaging of deep venous thrombosis
-
S. Aglyamov, A. R. Skovoroda, J. M. Rubin, M. O'Donnell, and S. Y. Emelianov, "Model-based reconstructive elasticity imaging of deep venous thrombosis," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 51, no. 5, pp. 521-531, 2004.
-
(2004)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr
, vol.51
, Issue.5
, pp. 521-531
-
-
Aglyamov, S.1
Skovoroda, A.R.2
Rubin, J.M.3
O'Donnell, M.4
Emelianov, S.Y.5
-
67
-
-
36849092323
-
Noninvasive vascular elastography: Toward a complementary characterization tool of atherosclerosis in carotid arteries
-
C. Schmitt, G. Soulez, R. L. Maurice, M. F. Giroux, and G. Cloutier, "Noninvasive vascular elastography: Toward a complementary characterization tool of atherosclerosis in carotid arteries," Ultrasound Med. Biol., vol. 33, no. 12, pp. 1841-1858, 2007.
-
(2007)
Ultrasound Med. Biol
, vol.33
, Issue.12
, pp. 1841-1858
-
-
Schmitt, C.1
Soulez, G.2
Maurice, R.L.3
Giroux, M.F.4
Cloutier, G.5
-
68
-
-
32044472533
-
Young's modulus reconstruction of vulnerable atherosclerotic plaque components using deformable curves
-
R. A. Baldewsing, F. Mastik, J. A. Schaar, P. W. Serruys, and A. F. W. van der Steen, "Young's modulus reconstruction of vulnerable atherosclerotic plaque components using deformable curves," Ultrasound Med. Biol., vol. 32, no. 2, pp. 201-210, 2006.
-
(2006)
Ultrasound Med. Biol
, vol.32
, Issue.2
, pp. 201-210
-
-
Baldewsing, R.A.1
Mastik, F.2
Schaar, J.A.3
Serruys, P.W.4
van der Steen, A.F.W.5
-
69
-
-
33845613478
-
Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom model
-
Y. Kawase, Y. Suzuki, F. Ikeno, R. Yoneyama, K. Hoshino, H. Q. Ly, G. T. Lau, M. Hayase, A. C. Yeung, R. J. Hajjar, and I. K. Jang, "Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom model," Ultrasound Med. Biol., vol. 33, no. 1, pp. 67-73, 2007.
-
(2007)
Ultrasound Med. Biol
, vol.33
, Issue.1
, pp. 67-73
-
-
Kawase, Y.1
Suzuki, Y.2
Ikeno, F.3
Yoneyama, R.4
Hoshino, K.5
Ly, H.Q.6
Lau, G.T.7
Hayase, M.8
Yeung, A.C.9
Hajjar, R.J.10
Jang, I.K.11
-
70
-
-
21644483386
-
Estimation of 2D displacement and strain field in high frequency ultrasound based elastography
-
M. Vogt, C. Perrey, and H. Ermert, "Estimation of 2D displacement and strain field in high frequency ultrasound based elastography," in Proc. IEEE Ultrason. Symp., 2004, pp. 376-379.
-
(2004)
Proc. IEEE Ultrason. Symp
, pp. 376-379
-
-
Vogt, M.1
Perrey, C.2
Ermert, H.3
-
71
-
-
44449097200
-
Azimuthal registration of image sequences affected by non-uniform rotation distortion
-
G. van Soest, J. G. Bosch, and A. F. W. van der Steen, "Azimuthal registration of image sequences affected by non-uniform rotation distortion," IEEE Trans. Inform. Technol. Biomed., vol. 12, no. 3, pp. 348-355, 2008.
-
(2008)
IEEE Trans. Inform. Technol. Biomed
, vol.12
, Issue.3
, pp. 348-355
-
-
van Soest, G.1
Bosch, J.G.2
van der Steen, A.F.W.3
|