메뉴 건너뛰기




Volumn 30, Issue 2, 2005, Pages 125-133

Three-dimensional palpography of human coronary arteries: Ex vivo validation and in-patient evaluation

Author keywords

Atherosclerosis; Catheters; Elasticity; Inflammation; Ultrasonic; Vulnerable plaque

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; ATHEROSCLEROTIC PLAQUE; CATHETER; CONTROLLED STUDY; CORONARY ARTERY; DEVICE; HUMAN; INTRAVASCULAR ULTRASOUND; MACROPHAGE; NONHUMAN; OBSERVATION; PALPOGRAM; PALPOGRAPHY; PRESSURE; RABBIT; REPRODUCIBILITY; THICKNESS; THREE DIMENSIONAL ECHOCARDIOGRAPHY; VASCULAR TISSUE;

EID: 17744399502     PISSN: 03409937     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00059-005-2642-4     Document Type: Article
Times cited : (45)

References (20)
  • 1
    • 3042621700 scopus 로고    scopus 로고
    • Terminology for high-risk and vulnerable coronary artery plaques
    • Report of a meeting on the vulnerable plaque, June 17 and 18, 2003, Santorini, Greece
    • Schaar JA, Muller JE, Falk E, et al. Terminology for high-risk and vulnerable coronary artery plaques. Report of a meeting on the vulnerable plaque, June 17 and 18, 2003, Santorini, Greece. Eur Heart J 2004;25:1077-82.
    • (2004) Eur Heart J , vol.25 , pp. 1077-1082
    • Schaar, J.A.1    Muller, J.E.2    Falk, E.3
  • 2
    • 0029800916 scopus 로고    scopus 로고
    • Stability and instability: Two faces of coronary atherosclerosis
    • Davies MJ. Stability and instability: two faces of coronary atherosclerosis. Circulation 1996;94:2013-20.
    • (1996) Circulation , vol.94 , pp. 2013-2020
    • Davies, M.J.1
  • 3
    • 0025980167 scopus 로고
    • Atherosclerotic plaque caps are locally weakened when macrophage density is increased
    • Lendon CL, Davies MJ, Born GVR, et al. Atherosclerotic plaque caps are locally weakened when macrophage density is increased. Atherosclerosis 1991;87:87-90.
    • (1991) Atherosclerosis , vol.87 , pp. 87-90
    • Lendon, C.L.1    Davies, M.J.2    Born, G.V.R.3
  • 4
    • 0032981584 scopus 로고    scopus 로고
    • Mechanisms of plaque rupture: Mechanical and biologic interactions
    • Arroyo L, Lee R. Mechanisms of plaque rupture: mechanical and biologic interactions. Cardiovasc Res 1999;41:369-75.
    • (1999) Cardiovasc Res , vol.41 , pp. 369-375
    • Arroyo, L.1    Lee, R.2
  • 5
    • 0034622623 scopus 로고    scopus 로고
    • Characterization of plaque components using intravascular ultrasound elastography in human femoral and coronary arteries in vitro
    • De Korte CL, Pasterkamp G, van der Steen AFW, et al. Characterization of plaque components using intravascular ultrasound elastography in human femoral and coronary arteries in vitro. Circulation 2000;102:617-23.
    • (2000) Circulation , vol.102 , pp. 617-623
    • De Korte, C.L.1    Pasterkamp, G.2    Van Der Steen, A.F.W.3
  • 6
    • 0344844424 scopus 로고    scopus 로고
    • Characterizing vulnerable plaque features with intravascular elastography
    • Schaar JA, de Korte CL, Mastik F, et al. Characterizing vulnerable plaque features with intravascular elastography. Circulation 2003;108:2636-41.
    • (2003) Circulation , vol.108 , pp. 2636-2641
    • Schaar, J.A.1    De Korte, C.L.2    Mastik, F.3
  • 7
    • 0037046228 scopus 로고    scopus 로고
    • Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo: A Yucatan pig study
    • De Korte CL, Sierevogel M, Mastik F, et al. Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo: a Yucatan pig study. Circulation 2002;105:1627-30.
    • (2002) Circulation , vol.105 , pp. 1627-1630
    • De Korte, C.L.1    Sierevogel, M.2    Mastik, F.3
  • 8
    • 0036522194 scopus 로고    scopus 로고
    • Morphological and mechanical information of coronary arteries obtained with intravascular elastography: A feasibility study in vivo
    • De Korte CL, Carlier SG, Mastik F, et al. Morphological and mechanical information of coronary arteries obtained with intravascular elastography: a feasibility study in vivo. Eur Heart J 2002;23:405-13.
    • (2002) Eur Heart J , vol.23 , pp. 405-413
    • De Korte, C.L.1    Carlier, S.G.2    Mastik, F.3
  • 9
    • 2942579077 scopus 로고    scopus 로고
    • Incidence of high-strain patterns in human coronary arteries: Assessment with three-dimensional intravascular palpography and correlation with clinical presentation
    • Schaar JA, Regar E, Mastik F, et al. Incidence of high-strain patterns in human coronary arteries: assessment with three-dimensional intravascular palpography and correlation with clinical presentation. Circulation 2004;109:2716-9.
    • (2004) Circulation , vol.109 , pp. 2716-2719
    • Schaar, J.A.1    Regar, E.2    Mastik, F.3
  • 10
    • 0032191886 scopus 로고    scopus 로고
    • A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues
    • Konofagou E, Ophir J. A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues. Ultrasound Med Biol 1998;24:1183-99.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 1183-1199
    • Konofagou, E.1    Ophir, J.2
  • 11
    • 0025806883 scopus 로고
    • Elastography: A method for imaging the elasticity in biological tissues
    • Ophir J, Céspedes EI, Ponnekanti H, et al. Elastography: a method for imaging the elasticity in biological tissues. Ultrason Imaging 1991;13:111-34.
    • (1991) Ultrason Imaging , vol.13 , pp. 111-134
    • Ophir, J.1    Céspedes, E.I.2    Ponnekanti, H.3
  • 12
    • 0031021607 scopus 로고    scopus 로고
    • PolyVinyl Alcohol Cryogel: An ideal phantom material for MR studies of arterial flow and elasticity
    • Chu K, Rutt B. PolyVinyl Alcohol Cryogel: an ideal phantom material for MR studies of arterial flow and elasticity. Magn Reson Med 1997;45:314-9.
    • (1997) Magn Reson Med , vol.45 , pp. 314-319
    • Chu, K.1    Rutt, B.2
  • 13
    • 0034254951 scopus 로고    scopus 로고
    • True 3-dimensional reconstruction of coronary arteries in patients by fusion of angiography and IVUS (ANGUS) and its quantitative validation
    • Slager C, Wentzel J, Schuurbiers J, et al. True 3-dimensional reconstruction of coronary arteries in patients by fusion of angiography and IVUS (ANGUS) and its quantitative validation. Circulation 2000;102:511-6.
    • (2000) Circulation , vol.102 , pp. 511-516
    • Slager, C.1    Wentzel, J.2    Schuurbiers, J.3
  • 14
    • 0029375496 scopus 로고
    • Theoretical bounds on strain estimation in elastography
    • Céspedes EI, Insana MF, Ophir J. Theoretical bounds on strain estimation in elastography. IEEE Trans UFFC 1995;42:969-72.
    • (1995) IEEE Trans UFFC , vol.42 , pp. 969-972
    • Céspedes, E.I.1    Insana, M.F.2    Ophir, J.3
  • 15
    • 0035660753 scopus 로고    scopus 로고
    • Advancing intravascular ultrasonic palpation towards clinical applications
    • Doyley M, Mastik F, de Korte CL, et al. Advancing intravascular ultrasonic palpation towards clinical applications. Ultrasound Med Biol 2001;27:1471-80.
    • (2001) Ultrasound Med Biol , vol.27 , pp. 1471-1480
    • Doyley, M.1    Mastik, F.2    De Korte, C.L.3
  • 17
    • 0030785945 scopus 로고    scopus 로고
    • The combined effect of signal decorrelation and random noise on the variance of time delay estimation
    • Céspedes EI, Ophir J, Alam SK. The combined effect of signal decorrelation and random noise on the variance of time delay estimation. IEEE Trans UFFC 1997;44:220-5.
    • (1997) IEEE Trans UFFC , vol.44 , pp. 220-225
    • Céspedes, E.I.1    Ophir, J.2    Alam, S.K.3
  • 18
    • 0032694295 scopus 로고    scopus 로고
    • Axial movement of the intravascular ultrasound probe during the cardiac cycle: Implications for three-dimensional reconstruction and measurements of coronary dimensions
    • Arbab-Zadeh A, DeMaria AN, Penny WF, et al. Axial movement of the intravascular ultrasound probe during the cardiac cycle: implications for three-dimensional reconstruction and measurements of coronary dimensions. Am Heart J 1999;138:865-72.
    • (1999) Am Heart J , vol.138 , pp. 865-872
    • Arbab-Zadeh, A.1    DeMaria, A.N.2    Penny, W.F.3
  • 19
    • 0026787340 scopus 로고
    • Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels
    • Loree HM, Kamm RD, Stringfellow RG, et al. Effects of fibrous cap thickness on peak circumferential stress in model atherosclerotic vessels. Circ Res 1992;71:850-8.
    • (1992) Circ Res , vol.71 , pp. 850-858
    • Loree, H.M.1    Kamm, R.D.2    Stringfellow, R.G.3
  • 20
    • 0037019329 scopus 로고    scopus 로고
    • Widespread coronary inflammation in unstable angina
    • Buffon A, Biasucci LM, Liuzzo G, et al. Widespread coronary inflammation in unstable angina. N Engl J Med 2002;347:5-12.
    • (2002) N Engl J Med , vol.347 , pp. 5-12
    • Buffon, A.1    Biasucci, L.M.2    Liuzzo, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.