Volumn 24, Issue 12, 2008, Pages 1506-1512
|
Relationship between failure behaviour and weld fusion zone attributes of austenitic stainless steel resistance spot welds
|
Author keywords
Austenitic stainless steel; Failure mode; Fusion zone size; Resistance spot weld
|
Indexed keywords
ABSORPTION;
AUSTENITE;
AUSTENITIC STAINLESS STEEL;
AUSTENITIC STEEL;
ELECTRIC WELDING;
ENERGY ABSORPTION;
FAILURE ANALYSIS;
FUSION REACTIONS;
HARDNESS;
INERT GAS WELDING;
MECHANICAL PROPERTIES;
RESISTANCE WELDING;
SPOT WELDING;
STEEL;
STEEL CORROSION;
STEEL METALLURGY;
STEEL SHEET;
WELDING;
WELDS;
ANALYTICAL MODELS;
AUSTENITIC;
ENERGY ABSORPTION CAPABILITIES;
FAILURE BEHAVIOURS;
FAILURE ENERGIES;
FAILURE LOCATIONS;
FAILURE MECHANISMS;
FUSION ZONE SIZE;
FUSION ZONES;
INDENTATION DEPTHS;
LOAD-CARRYING CAPACITIES;
MECHANICAL BEHAVIOURS;
PEAK LOADS;
RESISTANCE SPOT WELD;
RESISTANCE SPOT WELDING;
SHEAR TESTS;
SHEET THICKNESSES;
WELD FUSION ZONES;
STAINLESS STEEL;
|
EID: 56749159792
PISSN: 02670836
EISSN: None
Source Type: Journal
DOI: 10.1179/174328408X262418 Document Type: Article |
Times cited : (45)
|
References (18)
|