메뉴 건너뛰기




Volumn 124, Issue 5, 2008, Pages 3309-3314

Frequency dependence of backscatter from thin, oblique, finite-length cylinders measured with a focused transducer-with applications in cancellous bone

Author keywords

[No Author keywords available]

Indexed keywords

BACKSCATTER COEFFICIENTS; BEAM CENTERS; BROADBAND PULSES; CANCELLOUS BONES; CYLINDER AXIS; DIRECTIVITY PATTERNS; ECHO MEASUREMENTS; FREQUENCY DEPENDENCES; LATERAL DISPLACEMENTS; LINE INTEGRALS; MEMBRANE HYDROPHONES; POWER LAWS; SCATTERING PROPERTIES; ULTRASOUND BEAMS;

EID: 56749101842     PISSN: 00014966     EISSN: None     Source Type: Journal    
DOI: 10.1121/1.2980524     Document Type: Article
Times cited : (11)

References (28)
  • 1
    • 0033773586 scopus 로고    scopus 로고
    • Frequency dependence of ultrasonic backscattering in cancellous bone: Autocorrelation model and experimental results
    • " 0001-4966 10.1121/1.1316094.
    • Chaffai, S., Roberjot, V., Peyrin, F., Berger, G., and Laugier, P. (2000). " Frequency dependence of ultrasonic backscattering in cancellous bone: Autocorrelation model and experimental results.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.1316094 108, 2403-2411.
    • (2000) J. Acoust. Soc. Am. , vol.108 , pp. 2403-2411
    • Chaffai, S.1    Roberjot, V.2    Peyrin, F.3    Berger, G.4    Laugier, P.5
  • 2
    • 84955038759 scopus 로고
    • Sound scattering by solid cylinders and spheres
    • " 0001-4966 10.1121/1.1906780.
    • Faran, J. J., (1951). " Sound scattering by solid cylinders and spheres.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.1906780 23, 405-411.
    • (1951) J. Acoust. Soc. Am. , vol.23 , pp. 405-411
    • Faran, J.J.1
  • 5
    • 0023980552 scopus 로고
    • Hydrophone measurements in diagnostic ultrasound fields
    • 0885-3010 10.1109/58.4157.
    • Harris, G. R. (1988). " Hydrophone measurements in diagnostic ultrasound fields.," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 10.1109/58.4157 35, 87-101.
    • (1988) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.35 , pp. 87-101
    • Harris, G.R.1
  • 6
    • 0037363185 scopus 로고    scopus 로고
    • Prediction of frequency-dependent ultrasonic backscatter in cancellous bone using statistical weak scattering model
    • " 0301-5629 10.1016/S0301-5629(02)00742-1.
    • Jenson, F., Padilla, F., and Laugier, P. (2003). " Prediction of frequency-dependent ultrasonic backscatter in cancellous bone using statistical weak scattering model.," Ultrasound Med. Biol. 0301-5629 10.1016/S0301-5629(02)00742-1 29, 455-464.
    • (2003) Ultrasound Med. Biol. , vol.29 , pp. 455-464
    • Jenson, F.1    Padilla, F.2    Laugier, P.3
  • 7
    • 0017932869 scopus 로고
    • Swept-frequency diffraction of ultrasound by cylinders and arrays
    • " 0001-4966 10.1121/1.381759.
    • Lee, P. P. K., Waag, R. C., and Hunter, L. P. (1978). " Swept-frequency diffraction of ultrasound by cylinders and arrays.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.381759 63, 600-606.
    • (1978) J. Acoust. Soc. Am. , vol.63 , pp. 600-606
    • Lee, P.P.K.1    Waag, R.C.2    Hunter, L.P.3
  • 8
    • 0025365491 scopus 로고
    • Sound scattering of a spherical wave incident on a cylinder
    • 0001-4966 10.1121/1.399313.
    • Li, T., and Ueda, M. (1990a). " Sound scattering of a spherical wave incident on a cylinder.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.399313 87, 1871-1879.
    • (1990) J. Acoust. Soc. Am. , vol.87 , pp. 1871-1879
    • Li, T.1    Ueda, M.2
  • 9
    • 0025334688 scopus 로고
    • Analysis of echoes from a cylinder that includes the directivity of the transmitter and receiver
    • 0001-4966 10.1121/1.399314.
    • Li, T., and Ueda, M. (1990b). " Analysis of echoes from a cylinder that includes the directivity of the transmitter and receiver.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.399314 87, 1880-1879.
    • (1990) J. Acoust. Soc. Am. , vol.87 , pp. 1880-1879
    • Li, T.1    Ueda, M.2
  • 10
    • 0021491667 scopus 로고
    • Method of data reduction for accurate determination of acoustic backscatter coefficients
    • " 0001-4966 10.1121/1.391317.
    • Madsen, E. L., Insana, M. F., and Zagzebski, J. A. (1984). " Method of data reduction for accurate determination of acoustic backscatter coefficients.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.391317 76, 913-1879.
    • (1984) J. Acoust. Soc. Am. , vol.76 , pp. 913-1879
    • Madsen, E.L.1    Insana, M.F.2    Zagzebski, J.A.3
  • 11
    • 0036096812 scopus 로고    scopus 로고
    • Frequency-dependent attenuation-compensation functions for ultrasonic signals backscattered from random media
    • 0001-4966 10.1121/1.1452743.
    • Oelze, M. L., and O'Brien, W. D., Jr. (2002). " Frequency-dependent attenuation-compensation functions for ultrasonic signals backscattered from random media.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.1452743 111, 2308-1879.
    • (2002) J. Acoust. Soc. Am. , vol.111 , pp. 2308-1879
    • Oelze, M.L.1    O'brien Jr., W.D.2
  • 12
    • 0037324604 scopus 로고    scopus 로고
    • Prediction of backscatter coefficient in trabecular bones using a numerical model of three-dimensional microstructure
    • " 0001-4966 10.1121/1.1534835.
    • Padilla, F., Peyrin, F., and Laugier, P. (2003). " Prediction of backscatter coefficient in trabecular bones using a numerical model of three-dimensional microstructure.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.1534835 113, 1122-1879.
    • (2003) J. Acoust. Soc. Am. , vol.113 , pp. 1122-1879
    • Padilla, F.1    Peyrin, F.2    Laugier, P.3
  • 13
    • 0031187748 scopus 로고    scopus 로고
    • Pulse-echo field distribution measurement technique for high-frequency ultrasound sources
    • 0885-3010 10.1109/58.655196.
    • Raum, K., and O'Brien, W. D. (1997). " Pulse-echo field distribution measurement technique for high-frequency ultrasound sources.," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 10.1109/58.655196 44, 810-1879.
    • (1997) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.44 , pp. 810-1879
    • Raum, K.1    O'Brien, W.D.2
  • 15
    • 0027800633 scopus 로고
    • Spherical wave backscatter from straight cylinders: Thin-wire standard targets
    • 0001-4966 10.1121/1.407359.
    • Sheng, J., and Hay, A. (1993). " Spherical wave backscatter from straight cylinders: Thin-wire standard targets.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.407359 94, 2756-1879.
    • (1993) J. Acoust. Soc. Am. , vol.94 , pp. 2756-1879
    • Sheng, J.1    Hay, A.2
  • 16
    • 84967882475 scopus 로고
    • Sound scattering by cylinders of finite length. I. Fluid cylinders
    • Stanton, T. K. (1988a). " Sound scattering by cylinders of finite length. I. Fluid cylinders.," J. Acoust. Soc. Am. 83, 55-63.
    • (1988) J. Acoust. Soc. Am. , vol.83 , pp. 55-63
    • Stanton, T.K.1
  • 17
    • 84967805375 scopus 로고
    • Sound scattering by cylinders of finite length. II. Elastic cylinders
    • Stanton, T. K. (1988b). " Sound scattering by cylinders of finite length. II. Elastic cylinders.," J. Acoust. Soc. Am. 83, 64-67.
    • (1988) J. Acoust. Soc. Am. , vol.83 , pp. 64-67
    • Stanton, T.K.1
  • 18
    • 0027143875 scopus 로고
    • Ray representation of sound scattering by weakly scattering deformed fluid cylinders: Simple physics and application to zooplankton
    • ".
    • Stanton, T. K., Clay, C. S., and Chu, D. (1993a). " Ray representation of sound scattering by weakly scattering deformed fluid cylinders: Simple physics and application to zooplankton.," J. Acoust. Soc. Am. 94, 3454-3462.
    • (1993) J. Acoust. Soc. Am. , vol.94 , pp. 3454-3462
    • Stanton, T.K.1    Clay, C.S.2    Chu, D.3
  • 19
    • 0027138739 scopus 로고
    • Average echoes from randomly oriented random-length finite cylinders: Zooplankton models
    • ".
    • Stanton, T. K., Chu, D., Wiebe, P. H., and Clay, C. S., (1993b). " Average echoes from randomly oriented random-length finite cylinders: Zooplankton models.," J. Acoust. Soc. Am. 94, 3463-3472.
    • (1993) J. Acoust. Soc. Am. , vol.94 , pp. 3463-3472
    • Stanton, T.K.1    Chu, D.2    Wiebe, P.H.3    Clay, C.S.4
  • 21
    • 0032995520 scopus 로고    scopus 로고
    • The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
    • " 8756-3282 10.1016/S8756-3282(99)00098-8.
    • Ulrich, D., van Rietbergen, B., Laib, A., and Ruegsegger, P. (1999). " The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone.," Bone (N.Y.) 8756-3282 10.1016/S8756-3282(99) 00098-8 25, 55-60.
    • (1999) Bone (N.Y.) , vol.25 , pp. 55-60
    • Ulrich, D.1    Van Rietbergen, B.2    Laib, A.3    Ruegsegger, P.4
  • 22
    • 0032761734 scopus 로고    scopus 로고
    • Frequency dependence of ultrasonic backscatter from human trabecular bone: Theory and experiment
    • 0001-4966 10.1121/1.428218.
    • Wear, K. A. (1999). " Frequency dependence of ultrasonic backscatter from human trabecular bone: Theory and experiment.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.428218 106, 3659-3664.
    • (1999) J. Acoust. Soc. Am. , vol.106 , pp. 3659-3664
    • Wear, K.A.1
  • 23
    • 0034131128 scopus 로고    scopus 로고
    • Anisotropy of ultrasonic backscatter and attenuation from human calcaneus: Implications for relative roles of absorption and scattering in determining attenuation
    • 0001-4966 10.1121/1.429417.
    • Wear, K. A. (2000). " Anisotropy of ultrasonic backscatter and attenuation from human calcaneus: Implications for relative roles of absorption and scattering in determining attenuation.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.429417 107, 3474-3479.
    • (2000) J. Acoust. Soc. Am. , vol.107 , pp. 3474-3479
    • Wear, K.A.1
  • 24
    • 0035209136 scopus 로고    scopus 로고
    • Fundamental precision limitations for measurements of frequency dependence of backscatter: Applications in tissue-mimicking phantoms and trabecular bone
    • 0001-4966 10.1121/1.1416907.
    • Wear, K. A. (2001). " Fundamental precision limitations for measurements of frequency dependence of backscatter: Applications in tissue-mimicking phantoms and trabecular bone.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.1416907 110, 3275-3282.
    • (2001) J. Acoust. Soc. Am. , vol.110 , pp. 3275-3282
    • Wear, K.A.1
  • 25
    • 1642580531 scopus 로고    scopus 로고
    • Measurement of dependence of backscatter coefficient from cylinders on frequency and diameter using focused transducers-With applications in trabecular bone
    • Wear, K. A. (2004). " Measurement of dependence of backscatter coefficient from cylinders on frequency and diameter using focused transducers-With applications in trabecular bone.," J. Acoust. Soc. Am. 115, 66-72.
    • (2004) J. Acoust. Soc. Am. , vol.115 , pp. 66-72
    • Wear, K.A.1
  • 26
    • 23744507373 scopus 로고    scopus 로고
    • The dependences of phase velocity and dispersion on trabecular thickness and spacing in trabecular bone-mimicking phantoms
    • 0001-4966 10.1121/1.1940448.
    • Wear, K. A. (2005). " The dependences of phase velocity and dispersion on trabecular thickness and spacing in trabecular bone-mimicking phantoms.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.1940448 118, 1186-1192.
    • (2005) J. Acoust. Soc. Am. , vol.118 , pp. 1186-1192
    • Wear, K.A.1
  • 27
    • 0141957772 scopus 로고    scopus 로고
    • The relationship between ultrasonic scattering and microarchitecture in human calcaneus
    • 0885-3010 10.1109/TUFFC.2003.1226542.
    • Wear, K. A., and Laib, A. (2003). " The relationship between ultrasonic scattering and microarchitecture in human calcaneus.," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 10.1109/TUFFC.2003.1226542 50, 979-986.
    • (2003) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.50 , pp. 979-986
    • Wear, K.A.1    Laib, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.