-
1
-
-
33746737488
-
Safety of stress echocardiography (from the International Stress Echo Complication Registry)
-
Varga A., Garcia M.A., and Picano E. Safety of stress echocardiography (from the International Stress Echo Complication Registry). Am J Cardiol 98 (2006) 541-543
-
(2006)
Am J Cardiol
, vol.98
, pp. 541-543
-
-
Varga, A.1
Garcia, M.A.2
Picano, E.3
-
2
-
-
45849108271
-
Stress echocardiography expert consensus statement European Association of Echocardiography (EAE) (a registered branch of the ESC)
-
Sicari R., Nihoyannopoulos P., Evangelista A., Kasprzak J., Lancellotti P., Poldermans D., et al. Stress echocardiography expert consensus statement European Association of Echocardiography (EAE) (a registered branch of the ESC). Eur J Echocardiogr 9 (2008) 415-437
-
(2008)
Eur J Echocardiogr
, vol.9
, pp. 415-437
-
-
Sicari, R.1
Nihoyannopoulos, P.2
Evangelista, A.3
Kasprzak, J.4
Lancellotti, P.5
Poldermans, D.6
-
3
-
-
0027190017
-
Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients
-
Mertes H., Sawada S.G., Ryan T., Segar D.S., Kovacs R., Foltz J., et al. Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients. Circulation 88 (1993) 15-19
-
(1993)
Circulation
, vol.88
, pp. 15-19
-
-
Mertes, H.1
Sawada, S.G.2
Ryan, T.3
Segar, D.S.4
Kovacs, R.5
Foltz, J.6
-
4
-
-
0029435208
-
The side effects and safety of the echo-dobutamine test. The experience with 373 patients
-
Fetiveau R., Lanzarini L., Poli A., Diotallevi P., Mussini M.F., Montemartini C., et al. The side effects and safety of the echo-dobutamine test. The experience with 373 patients. G Ital Cardiol 25 (1995) 193-201
-
(1995)
G Ital Cardiol
, vol.25
, pp. 193-201
-
-
Fetiveau, R.1
Lanzarini, L.2
Poli, A.3
Diotallevi, P.4
Mussini, M.F.5
Montemartini, C.6
-
5
-
-
0027959932
-
Safety and tolerability of dobutamine-atropine stress echocardiography: a prospective, multicentre study: Echo Dobutamine International Cooperative Study Group
-
Picano E., Mathias Jr. W., Pingitore A., Bigi R., and Previtali M. Safety and tolerability of dobutamine-atropine stress echocardiography: a prospective, multicentre study: Echo Dobutamine International Cooperative Study Group. Lancet 344 (1994) 1190-1192
-
(1994)
Lancet
, vol.344
, pp. 1190-1192
-
-
Picano, E.1
Mathias Jr., W.2
Pingitore, A.3
Bigi, R.4
Previtali, M.5
-
6
-
-
0028919118
-
Stress echocardiography. Part II. Dobutamine stress echocardiography: techniques, implementation, clinical applications, and correlations
-
Pellikka P.A., Roger V.L., Oh J.K., Miller F.A., Seward J.B., Tajik A.J., et al. Stress echocardiography. Part II. Dobutamine stress echocardiography: techniques, implementation, clinical applications, and correlations. Mayo Clin Proc 70 (1995) 16-27
-
(1995)
Mayo Clin Proc
, vol.70
, pp. 16-27
-
-
Pellikka, P.A.1
Roger, V.L.2
Oh, J.K.3
Miller, F.A.4
Seward, J.B.5
Tajik, A.J.6
-
7
-
-
0029715636
-
Safety and feasibility of dobutamine-atropine stress echocardiography in patients with ischemic left ventricular dysfunction
-
Cornel J.H., Balk A.H., Boersma E., Maat A.P., Elhendy A., Arnese M., et al. Safety and feasibility of dobutamine-atropine stress echocardiography in patients with ischemic left ventricular dysfunction. J Am Soc Echocardiogr 9 (1996) 27-32
-
(1996)
J Am Soc Echocardiogr
, vol.9
, pp. 27-32
-
-
Cornel, J.H.1
Balk, A.H.2
Boersma, E.3
Maat, A.P.4
Elhendy, A.5
Arnese, M.6
-
8
-
-
0030043861
-
Feasibility and safety of dobutamine stress echocardiography: experiences with 1,000 studies
-
Zahn R., Lotter R., Nohl H., Schiele R., Bergmeier C., Zander M., et al. Feasibility and safety of dobutamine stress echocardiography: experiences with 1,000 studies. Z Kardiol 85 (1996) 28-34
-
(1996)
Z Kardiol
, vol.85
, pp. 28-34
-
-
Zahn, R.1
Lotter, R.2
Nohl, H.3
Schiele, R.4
Bergmeier, C.5
Zander, M.6
-
9
-
-
0029795101
-
Dipyridamole and dobutamine-atropine stress echocardiography in the diagnosis of coronary artery disease. Comparison with exercise stress test, analysis of agreement, and impact of antianginal treatment
-
San Román J.A., Vilacosta I., Castillo J.A., Rollán M.J., Peral V., Sánchez-Harguindey L., et al. Dipyridamole and dobutamine-atropine stress echocardiography in the diagnosis of coronary artery disease. Comparison with exercise stress test, analysis of agreement, and impact of antianginal treatment. Chest 110 (1996) 1248-1254
-
(1996)
Chest
, vol.110
, pp. 1248-1254
-
-
San Román, J.A.1
Vilacosta, I.2
Castillo, J.A.3
Rollán, M.J.4
Peral, V.5
Sánchez-Harguindey, L.6
-
10
-
-
0029949864
-
Adverse effects of dobutamine stress echocardiography
-
Cladellas Capdevila M., Bruguera Cortada J., Hernández Herrero J., Villena Segura J., and Serrat Serradell R. Adverse effects of dobutamine stress echocardiography. Rev Esp Cardiol 49 (1996) 22-28
-
(1996)
Rev Esp Cardiol
, vol.49
, pp. 22-28
-
-
Cladellas Capdevila, M.1
Bruguera Cortada, J.2
Hernández Herrero, J.3
Villena Segura, J.4
Serrat Serradell, R.5
-
11
-
-
0030958384
-
Evolution of dobutamine echocardiography protocols and indications: safety and side effects in 3011studies over 5 years
-
6
-
Secknus M.A., and Marwick T.H. Evolution of dobutamine echocardiography protocols and indications: safety and side effects in 3011studies over 5 years. J Am Coll Cardiol 29 (1997) 1234-1240 6
-
(1997)
J Am Coll Cardiol
, vol.29
, pp. 1234-1240
-
-
Secknus, M.A.1
Marwick, T.H.2
-
12
-
-
0030994120
-
Safety and feasibility of dobutamine-atropine stress testing in hypertensive patients
-
Elhendy A., van Domburg R.T., Roelandt J.R., Geleijnse M.L., Ibrahim M.M., and Fioretti P.M. Safety and feasibility of dobutamine-atropine stress testing in hypertensive patients. Hypertension 29 (1997) 1232-1239
-
(1997)
Hypertension
, vol.29
, pp. 1232-1239
-
-
Elhendy, A.1
van Domburg, R.T.2
Roelandt, J.R.3
Geleijnse, M.L.4
Ibrahim, M.M.5
Fioretti, P.M.6
-
13
-
-
0030962322
-
Safety of dobutamine stress echocardiography in 474 consecutive studies
-
Hennessy T.G., Codd M.B., Kane G., McCarthy C., McCann H.A., and Sugrue D.D. Safety of dobutamine stress echocardiography in 474 consecutive studies. Coron Artery Dis 8 (1997) 175-178
-
(1997)
Coron Artery Dis
, vol.8
, pp. 175-178
-
-
Hennessy, T.G.1
Codd, M.B.2
Kane, G.3
McCarthy, C.4
McCann, H.A.5
Sugrue, D.D.6
-
14
-
-
0031219289
-
Symptoms, complications and hemodynamic changes related to dobutamine stress echocardiography
-
Pinton R., Lemke W., and Garcia L.G. Symptoms, complications and hemodynamic changes related to dobutamine stress echocardiography. Arq Bras Cardiol 69 (1997) 161-164
-
(1997)
Arq Bras Cardiol
, vol.69
, pp. 161-164
-
-
Pinton, R.1
Lemke, W.2
Garcia, L.G.3
-
15
-
-
9844263752
-
Safety and feasibility of dobutamine-atropine stress echocardiography
-
Mathias Júnior W., Beneti L.P., dos Santos F.C., Duprat R., Beraldo A., Gil M.A., et al. Safety and feasibility of dobutamine-atropine stress echocardiography. Arq Bras Cardiol 69 (1997) 31-34
-
(1997)
Arq Bras Cardiol
, vol.69
, pp. 31-34
-
-
Mathias Júnior, W.1
Beneti, L.P.2
dos Santos, F.C.3
Duprat, R.4
Beraldo, A.5
Gil, M.A.6
-
16
-
-
0031264476
-
Dobutamine stress echocardiography; a monocentric experience on 600 consecutive patients. Effect of age
-
Lamisse N., Cohen A., Chauvel C., Benhalima B., Désert I., Buyukoglu B., et al. Dobutamine stress echocardiography; a monocentric experience on 600 consecutive patients. Effect of age. Arch Mal Coeur Vaiss 90 (1997) 1455-1461
-
(1997)
Arch Mal Coeur Vaiss
, vol.90
, pp. 1455-1461
-
-
Lamisse, N.1
Cohen, A.2
Chauvel, C.3
Benhalima, B.4
Désert, I.5
Buyukoglu, B.6
-
17
-
-
0033002753
-
Relation between the extent of coronary artery disease and tachyarrhythmias during dobutamine stress echocardiography
-
Elhendy A., van Domburg R.T., Bax J.J., and Roelandt J.R. Relation between the extent of coronary artery disease and tachyarrhythmias during dobutamine stress echocardiography. Am J Cardiol 83 (1999) 832-835
-
(1999)
Am J Cardiol
, vol.83
, pp. 832-835
-
-
Elhendy, A.1
van Domburg, R.T.2
Bax, J.J.3
Roelandt, J.R.4
-
18
-
-
0031935799
-
RITED (Registro Italiano Test Eco-Dobutamina): side effects and complications of echo-dobutamine stress test in 3041 examinations
-
Pezzano A., Gentile F., Mantero A., Morabito A., and Ravizza P. RITED (Registro Italiano Test Eco-Dobutamina): side effects and complications of echo-dobutamine stress test in 3041 examinations. G Ital Cardiol 28 (1998) 102-111
-
(1998)
G Ital Cardiol
, vol.28
, pp. 102-111
-
-
Pezzano, A.1
Gentile, F.2
Mantero, A.3
Morabito, A.4
Ravizza, P.5
-
19
-
-
0031859299
-
Safety of dobutamine stress echocardiography supervised by registered nurse sonographers
-
Bremer M.L., Monahan K.H., Stussy V.L., Miller Jr. F.A., Seward J.B., and Pellikka P.A. Safety of dobutamine stress echocardiography supervised by registered nurse sonographers. J Am Soc Echocardiogr 11 (1998) 601-605
-
(1998)
J Am Soc Echocardiogr
, vol.11
, pp. 601-605
-
-
Bremer, M.L.1
Monahan, K.H.2
Stussy, V.L.3
Miller Jr., F.A.4
Seward, J.B.5
Pellikka, P.A.6
-
20
-
-
0033205955
-
Side effects during dobutamine stress echocardiography: analysis of 582 studies
-
Płońska E., Szwed H., Gasior Z., Drozdz J., Gackowski A., Szyszka A., et al. Side effects during dobutamine stress echocardiography: analysis of 582 studies. Pol Merkur Lekarski 7 (1999) 164-168
-
(1999)
Pol Merkur Lekarski
, vol.7
, pp. 164-168
-
-
Płońska, E.1
Szwed, H.2
Gasior, Z.3
Drozdz, J.4
Gackowski, A.5
Szyszka, A.6
-
21
-
-
0033021539
-
Comparison of three different protocols for dobutamine stress echocardiography: does the addition of atropine increase complications, and does it improve diagnostic accuracy?
-
Takeuchi M., Miura Y., Sonoda S., and Kuroiwa A. Comparison of three different protocols for dobutamine stress echocardiography: does the addition of atropine increase complications, and does it improve diagnostic accuracy?. Echocardiography 16 (1999) 347-355
-
(1999)
Echocardiography
, vol.16
, pp. 347-355
-
-
Takeuchi, M.1
Miura, Y.2
Sonoda, S.3
Kuroiwa, A.4
-
22
-
-
0032911533
-
Long-term prognostic value of dobutamine-atropine stress echocardiography in 1737 patients with known or suspected coronary artery disease: a single-center experience
-
Poldermans D., Fioretti P.M., Boersma E., Bax J., Thomson I., Roelandt J., et al. Long-term prognostic value of dobutamine-atropine stress echocardiography in 1737 patients with known or suspected coronary artery disease: a single-center experience. Circulation 99 (1999) 757-762
-
(1999)
Circulation
, vol.99
, pp. 757-762
-
-
Poldermans, D.1
Fioretti, P.M.2
Boersma, E.3
Bax, J.4
Thomson, I.5
Roelandt, J.6
-
23
-
-
0032834445
-
Safety of dobutamine-atropine stress echocardiography: a prospective experience of 4,033 consecutive studies
-
Mathias Jr. W., Arruda A., Santos F.C., Arruda A.L., Mattos E., Oso'rio A., et al. Safety of dobutamine-atropine stress echocardiography: a prospective experience of 4,033 consecutive studies. J Am Soc Echocardiogr 12 (1999) 785-791
-
(1999)
J Am Soc Echocardiogr
, vol.12
, pp. 785-791
-
-
Mathias Jr., W.1
Arruda, A.2
Santos, F.C.3
Arruda, A.L.4
Mattos, E.5
Oso'rio, A.6
-
24
-
-
0035091502
-
Safety, feasibility, and prognostic implications of pharmacologic stress echocardiography in 1482 patients evaluated in an ambulatory setting
-
Echo Persantine International Cooperative (EPIC) Study Group; Echo Dobutamine International Cooperative (EDIC) Study Group
-
Cortigiani L., Picano E., Coletta C., Chiarella F., Mathias W., Gandolfo N., et al., Echo Persantine International Cooperative (EPIC) Study Group; Echo Dobutamine International Cooperative (EDIC) Study Group. Safety, feasibility, and prognostic implications of pharmacologic stress echocardiography in 1482 patients evaluated in an ambulatory setting. Am Heart J 141 (2001) 621-629
-
(2001)
Am Heart J
, vol.141
, pp. 621-629
-
-
Cortigiani, L.1
Picano, E.2
Coletta, C.3
Chiarella, F.4
Mathias, W.5
Gandolfo, N.6
-
25
-
-
0034870597
-
Complications of stress echocardiography
-
Hirano Y., Yamamoto T., Uehara H., Nakamura H., Wufuer M., and Yamada S. Complications of stress echocardiography. J Cardiol 38 (2001) 73-80
-
(2001)
J Cardiol
, vol.38
, pp. 73-80
-
-
Hirano, Y.1
Yamamoto, T.2
Uehara, H.3
Nakamura, H.4
Wufuer, M.5
Yamada, S.6
-
26
-
-
0036656322
-
Complications in stress echocardiography
-
João I., Cotrim C., do Rosário L., Duarte J.A., Freire G., Fazendas P., et al. Complications in stress echocardiography. Rev Port Cardiol 21 (2002) 871-881
-
(2002)
Rev Port Cardiol
, vol.21
, pp. 871-881
-
-
João, I.1
Cotrim, C.2
do Rosário, L.3
Duarte, J.A.4
Freire, G.5
Fazendas, P.6
-
27
-
-
0036628764
-
Safety and feasibility of dobutamine and dipyridamole stress echocardiography in hypertensive patients
-
Cortigiani L., Zanetti L., Bigi R., Desideri A., Fiorentini C., and Nannini E. Safety and feasibility of dobutamine and dipyridamole stress echocardiography in hypertensive patients. J Hypertens 20 (2002) 1423-1429
-
(2002)
J Hypertens
, vol.20
, pp. 1423-1429
-
-
Cortigiani, L.1
Zanetti, L.2
Bigi, R.3
Desideri, A.4
Fiorentini, C.5
Nannini, E.6
-
28
-
-
1542542009
-
Safety of exercise and dobutamine stress echocardiography (results of 2383 tests)
-
Persianov-Dubrov I.V., Alekhin M.N., Gogin G.E., Glezer M.G., and Sidorenko B.A. Safety of exercise and dobutamine stress echocardiography (results of 2383 tests). Kardiologiia 43 (2003) 18-22
-
(2003)
Kardiologiia
, vol.43
, pp. 18-22
-
-
Persianov-Dubrov, I.V.1
Alekhin, M.N.2
Gogin, G.E.3
Glezer, M.G.4
Sidorenko, B.A.5
-
29
-
-
7044264397
-
Safety of dobutamine stress transesophageal echocardiography in obese patients for evaluation of potential ischemic heart disease
-
Siddiqui T.S., and Stoddard M.F. Safety of dobutamine stress transesophageal echocardiography in obese patients for evaluation of potential ischemic heart disease. Echocardiography 21 (2004) 603-608
-
(2004)
Echocardiography
, vol.21
, pp. 603-608
-
-
Siddiqui, T.S.1
Stoddard, M.F.2
-
30
-
-
9344262899
-
Comparison of safety and efficacy of the early injection of atropine during dobutamine stress echocardiography with the conventional protocol
-
Tsutsui J.M., Osório A.F., Lario F.A., Fernandes D.R., Sodre G., Andrade J.L., et al. Comparison of safety and efficacy of the early injection of atropine during dobutamine stress echocardiography with the conventional protocol. Am J Cardiol 94 (2004) 1367-1372
-
(2004)
Am J Cardiol
, vol.94
, pp. 1367-1372
-
-
Tsutsui, J.M.1
Osório, A.F.2
Lario, F.A.3
Fernandes, D.R.4
Sodre, G.5
Andrade, J.L.6
-
31
-
-
25144512849
-
Safety and feasibility of dobutamine-atropine stress echocardiography in octogenarian patients
-
Abreu J.S., Diógenes T.C., Farias A.G., Morais J.M., and Paes Júnior J.N. Safety and feasibility of dobutamine-atropine stress echocardiography in octogenarian patients. Arq Bras Cardiol 85 (2005) 198-204
-
(2005)
Arq Bras Cardiol
, vol.85
, pp. 198-204
-
-
Abreu, J.S.1
Diógenes, T.C.2
Farias, A.G.3
Morais, J.M.4
Paes Júnior, J.N.5
-
32
-
-
17144371517
-
Safety of dobutamine stress real-time myocardial contrast echocardiography
-
Tsutsui J.M., Elhendy A., Xie F., O'Leary E.L., McGrain A.C., Porter T.R., et al. Safety of dobutamine stress real-time myocardial contrast echocardiography. J Am Coll Cardiol 45 (2005) 1235-1242
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 1235-1242
-
-
Tsutsui, J.M.1
Elhendy, A.2
Xie, F.3
O'Leary, E.L.4
McGrain, A.C.5
Porter, T.R.6
-
33
-
-
23744461385
-
Sustained ventricular tachycardia induced by dobutamine stress echocardiography: a prospective study
-
Katritsis D.G., Karabinos I.K., Papadopoulos A., Simeonidis P., Korovesis S., Giazitzoglou E., et al. Sustained ventricular tachycardia induced by dobutamine stress echocardiography: a prospective study. Europace 7 (2005) 433-439
-
(2005)
Europace
, vol.7
, pp. 433-439
-
-
Katritsis, D.G.1
Karabinos, I.K.2
Papadopoulos, A.3
Simeonidis, P.4
Korovesis, S.5
Giazitzoglou, E.6
-
34
-
-
28144453909
-
Safety and cardiac chronotropic responsiveness to the early injection of atropine during dobutamine stress echocardiography in the elderly
-
Tsutsui J.M., Lario F.C., Fernandes D.R., Kowatsch I., Sbano J.C., Franchini Ramires J.A., et al. Safety and cardiac chronotropic responsiveness to the early injection of atropine during dobutamine stress echocardiography in the elderly. Heart 91 (2005) 1563-1567
-
(2005)
Heart
, vol.91
, pp. 1563-1567
-
-
Tsutsui, J.M.1
Lario, F.C.2
Fernandes, D.R.3
Kowatsch, I.4
Sbano, J.C.5
Franchini Ramires, J.A.6
-
35
-
-
12844265511
-
Safety of contrast dobutamine stress echocardiography: a single center experience
-
Timperley J., Mitchell A.R., Thibault H., Mirza I.H., and Becher H. Safety of contrast dobutamine stress echocardiography: a single center experience. J Am Soc Echocardiogr 18 (2005) 163-167
-
(2005)
J Am Soc Echocardiogr
, vol.18
, pp. 163-167
-
-
Timperley, J.1
Mitchell, A.R.2
Thibault, H.3
Mirza, I.H.4
Becher, H.5
-
36
-
-
33746156981
-
Prevalence of dangerous arrhythmia during pharmacological stress echocardiography
-
Wejner-Mik P., Drozdz J., Lipiec P., Krzemińska-Pakuła M., Ciesielczyk M., and Kasprzak J.D. Prevalence of dangerous arrhythmia during pharmacological stress echocardiography. Pol Merkur Lekarski 20 (2006) 635-638
-
(2006)
Pol Merkur Lekarski
, vol.20
, pp. 635-638
-
-
Wejner-Mik, P.1
Drozdz, J.2
Lipiec, P.3
Krzemińska-Pakuła, M.4
Ciesielczyk, M.5
Kasprzak, J.D.6
-
37
-
-
54949156274
-
Safety of myocardial flash-contrast echocardiography in combination with dobutamine stress testing for detection of ischemia in 5250 studies
-
May 12. [Epub ahead of print]
-
Aggeli C., Giannopoulos G., Roussakis G., Christoforatou E., Marinos G., Toli C., et al. Safety of myocardial flash-contrast echocardiography in combination with dobutamine stress testing for detection of ischemia in 5250 studies. Heart (2008) May 12. [Epub ahead of print]
-
(2008)
Heart
-
-
Aggeli, C.1
Giannopoulos, G.2
Roussakis, G.3
Christoforatou, E.4
Marinos, G.5
Toli, C.6
-
38
-
-
41249102820
-
Safety of stress echocardiography supervised by registered nurses: results of a 2-year audit of 15,404 patients
-
Kane G.C., Hepinstall M.J., Kidd G.M., Kuehl C.A., Murphy A.T., Nelson J.M., et al. Safety of stress echocardiography supervised by registered nurses: results of a 2-year audit of 15,404 patients. J Am Soc Echocardiogr 21 (2008) 337-341
-
(2008)
J Am Soc Echocardiogr
, vol.21
, pp. 337-341
-
-
Kane, G.C.1
Hepinstall, M.J.2
Kidd, G.M.3
Kuehl, C.A.4
Murphy, A.T.5
Nelson, J.M.6
-
39
-
-
42149099386
-
Complications of stress-echocardiography used for diagnosis of ischemic heart disease
-
Mikheev N.N. Complications of stress-echocardiography used for diagnosis of ischemic heart disease. Kardiologiia 48 (2008) 19-23
-
(2008)
Kardiologiia
, vol.48
, pp. 19-23
-
-
Mikheev, N.N.1
-
40
-
-
37349090421
-
Safety and predictors of complications with a new accelerated dobutamine stress echocardiography protocol
-
San Román J.A., Sanz-Ruiz R., Ortega J.R., Pérez-Paredes M., Rollán M.J., Muñoz A.C., et al. Safety and predictors of complications with a new accelerated dobutamine stress echocardiography protocol. J Am Soc Echocardiogr 21 (2008) 53-57
-
(2008)
J Am Soc Echocardiogr
, vol.21
, pp. 53-57
-
-
San Román, J.A.1
Sanz-Ruiz, R.2
Ortega, J.R.3
Pérez-Paredes, M.4
Rollán, M.J.5
Muñoz, A.C.6
-
41
-
-
38349062415
-
Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography
-
Minardi G., Manzara C., Pulignano G., Pino P.G., Pavaci H., and Sordi M. Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography. Cardiovasc Ultrasound 5 (2007) 40
-
(2007)
Cardiovasc Ultrasound
, vol.5
, pp. 40
-
-
Minardi, G.1
Manzara, C.2
Pulignano, G.3
Pino, P.G.4
Pavaci, H.5
Sordi, M.6
-
42
-
-
0041402646
-
Safety of dobutamine stress echocardiography in patients with aortic stenosis
-
Bountioukos M., Kertai M.D., Schinkel A.F., Vourvouri E.C., Rizzello V., Krenning B.J., et al. Safety of dobutamine stress echocardiography in patients with aortic stenosis. J Heart Valve Dis 12 (2003) 441-446
-
(2003)
J Heart Valve Dis
, vol.12
, pp. 441-446
-
-
Bountioukos, M.1
Kertai, M.D.2
Schinkel, A.F.3
Vourvouri, E.C.4
Rizzello, V.5
Krenning, B.J.6
-
43
-
-
0029548936
-
Incidence and correlates of complex ventricular arrhythmias during dobutamine stress echocardiography after acute myocardial infarction
-
Bigi R., Partesana N., Verzoni A., Bandini P., Maffi M., Longoni A., et al. Incidence and correlates of complex ventricular arrhythmias during dobutamine stress echocardiography after acute myocardial infarction. Eur Heart J 16 (1995) 1819-1824
-
(1995)
Eur Heart J
, vol.16
, pp. 1819-1824
-
-
Bigi, R.1
Partesana, N.2
Verzoni, A.3
Bandini, P.4
Maffi, M.5
Longoni, A.6
-
44
-
-
0030999884
-
Safety and accuracy of dobutamine-atropine stress echocardiography for the detection of residual stenosis of the infarct-related artery and multivessel disease during the first week after acute myocardial infarction
-
Smart S.C., Knickelbine T., Stoiber T.R., Carlos M., Wynsen J.C., and Sagar K.B. Safety and accuracy of dobutamine-atropine stress echocardiography for the detection of residual stenosis of the infarct-related artery and multivessel disease during the first week after acute myocardial infarction. Circulation 95 (1997) 1394-1401
-
(1997)
Circulation
, vol.95
, pp. 1394-1401
-
-
Smart, S.C.1
Knickelbine, T.2
Stoiber, T.R.3
Carlos, M.4
Wynsen, J.C.5
Sagar, K.B.6
-
45
-
-
0031782680
-
Safety and feasibility of dobutamine-atropine stress echocardiography for the diagnosis of coronary artery disease in diabetic patients unable to perform an exercise stress test
-
Elhendy A., van Domburg R.T., Poldermans D., Bax J.J., Nierop P.R., Geleijnse M.L., et al. Safety and feasibility of dobutamine-atropine stress echocardiography for the diagnosis of coronary artery disease in diabetic patients unable to perform an exercise stress test. Diabetes Care 21 (1998) 1797-1802
-
(1998)
Diabetes Care
, vol.21
, pp. 1797-1802
-
-
Elhendy, A.1
van Domburg, R.T.2
Poldermans, D.3
Bax, J.J.4
Nierop, P.R.5
Geleijnse, M.L.6
-
46
-
-
7144252531
-
Induction of torsades de pointes by dobutamine infusion in a patient with idiopathic long QT syndrome
-
Fujikawa H., Sato Y., Arakawa H., Mitsuhashi T., Minezaki K., Kuroki S., et al. Induction of torsades de pointes by dobutamine infusion in a patient with idiopathic long QT syndrome. Intern Med 37 (1998) 149-152
-
(1998)
Intern Med
, vol.37
, pp. 149-152
-
-
Fujikawa, H.1
Sato, Y.2
Arakawa, H.3
Mitsuhashi, T.4
Minezaki, K.5
Kuroki, S.6
-
47
-
-
25444475514
-
Complications during pharmacological stress echocardiography: a video-case series
-
Varga A., Kraft G., Lakatos F., Bigi R., Paya R., and Picano E. Complications during pharmacological stress echocardiography: a video-case series. Cardiovascular Ultrasound 3 (2005) 25
-
(2005)
Cardiovascular Ultrasound
, vol.3
, pp. 25
-
-
Varga, A.1
Kraft, G.2
Lakatos, F.3
Bigi, R.4
Paya, R.5
Picano, E.6
-
48
-
-
33644831915
-
Spontaneous coronary artery dissection during a dobutamine stress echocardiography
-
Karabinos I., Papadopoulos A., Koulouris S., Kranidis A., Korovesis S., Katritsis D., et al. Spontaneous coronary artery dissection during a dobutamine stress echocardiography. Echocardiography 23 (2006) 232-234
-
(2006)
Echocardiography
, vol.23
, pp. 232-234
-
-
Karabinos, I.1
Papadopoulos, A.2
Koulouris, S.3
Kranidis, A.4
Korovesis, S.5
Katritsis, D.6
-
49
-
-
34748842685
-
Ventricular fibrillation in late recovery after dobutamine stress echocardiography
-
Epub 2007 Jul 27
-
Jiamsripong P., Honda T., McCully R., Khandheria B., and Mookadam F. Ventricular fibrillation in late recovery after dobutamine stress echocardiography. J Am Soc Echocardiogr 20 (2007) 1220.e7-1220.e10 Epub 2007 Jul 27
-
(2007)
J Am Soc Echocardiogr
, vol.20
-
-
Jiamsripong, P.1
Honda, T.2
McCully, R.3
Khandheria, B.4
Mookadam, F.5
-
50
-
-
0037299764
-
Long term prognostic significance of complex ventricular arrhythmias induced during dobutamine stress echocardiography
-
Sutter J., Poldermans D., Vourvouri E., Van Donburg R., Elhendy A., Bax J., et al. Long term prognostic significance of complex ventricular arrhythmias induced during dobutamine stress echocardiography. Am J Cardiol 91 (2003) 242-244
-
(2003)
Am J Cardiol
, vol.91
, pp. 242-244
-
-
Sutter, J.1
Poldermans, D.2
Vourvouri, E.3
Van Donburg, R.4
Elhendy, A.5
Bax, J.6
-
51
-
-
4444346401
-
Myocardial ischemia and induction of sustained ventricular tachyarrhythmias: evaluation using dobutamine stress echocardiography-electrophysiologic testing
-
Stambler B.S., Akosah K.O., Mohanty P.K., Wood M.A., and Ellenbogen K.A. Myocardial ischemia and induction of sustained ventricular tachyarrhythmias: evaluation using dobutamine stress echocardiography-electrophysiologic testing. J Cardiovasc Electrophysiol 15 (2004) 901-907
-
(2004)
J Cardiovasc Electrophysiol
, vol.15
, pp. 901-907
-
-
Stambler, B.S.1
Akosah, K.O.2
Mohanty, P.K.3
Wood, M.A.4
Ellenbogen, K.A.5
-
52
-
-
0020676118
-
Electrophysiologic mechanism of exercise-induced sustained ventricular tachycardia
-
Sung R.J., Shen E.N., Morady F., Scheinman M.M., Hess D., and Botvinick E.H. Electrophysiologic mechanism of exercise-induced sustained ventricular tachycardia. Am J Cardiol 51 (1983) 525-530
-
(1983)
Am J Cardiol
, vol.51
, pp. 525-530
-
-
Sung, R.J.1
Shen, E.N.2
Morady, F.3
Scheinman, M.M.4
Hess, D.5
Botvinick, E.H.6
-
53
-
-
0019446622
-
Exercise triggered paroxysmal ventricular tachycardia. A repetitive rhythmic activity possibly related to after depolarization
-
Wu D., Kou H.C., and Hung J.S. Exercise triggered paroxysmal ventricular tachycardia. A repetitive rhythmic activity possibly related to after depolarization. Ann Intern Med 95 (1981) 410-414
-
(1981)
Ann Intern Med
, vol.95
, pp. 410-414
-
-
Wu, D.1
Kou, H.C.2
Hung, J.S.3
-
54
-
-
0023754674
-
Mechanism of death and prevalence of myocardial ischemic symptoms in the terminal event after acute myocardial infarction
-
Marcus F.I., Cobb L.A., Edwards J.E., Kuller L., Moss A.J., Bigger J.T., et al. Mechanism of death and prevalence of myocardial ischemic symptoms in the terminal event after acute myocardial infarction. Am J Cardiol 61 (1988) 8-15
-
(1988)
Am J Cardiol
, vol.61
, pp. 8-15
-
-
Marcus, F.I.1
Cobb, L.A.2
Edwards, J.E.3
Kuller, L.4
Moss, A.J.5
Bigger, J.T.6
-
55
-
-
0020352711
-
Exercise provocable right ventricular outflow tract tachycardia
-
Palileo E.V., Ashley W.W., Swiryn S., Bauernfeind R.A., Strasberg B., Petropoulos A.T., et al. Exercise provocable right ventricular outflow tract tachycardia. Am Heart J 104 (1982) 185
-
(1982)
Am Heart J
, vol.104
, pp. 185
-
-
Palileo, E.V.1
Ashley, W.W.2
Swiryn, S.3
Bauernfeind, R.A.4
Strasberg, B.5
Petropoulos, A.T.6
-
56
-
-
0025784227
-
Changes in plasma potassium during the dobutamine stress test
-
Coma-Canella I. Changes in plasma potassium during the dobutamine stress test. Int J Cardiol 33 (1991) 55-59
-
(1991)
Int J Cardiol
, vol.33
, pp. 55-59
-
-
Coma-Canella, I.1
-
57
-
-
0031809005
-
Platelet activation during dobutamine stress echocardiography
-
Galloway M.T., Paglieroni T.G., Wun T., Arena F.J., and Lewis W.R. Platelet activation during dobutamine stress echocardiography. Am Heart J 135 (1998) 888-900
-
(1998)
Am Heart J
, vol.135
, pp. 888-900
-
-
Galloway, M.T.1
Paglieroni, T.G.2
Wun, T.3
Arena, F.J.4
Lewis, W.R.5
-
58
-
-
0026717236
-
Electrophysiologic effects of selective B1 adrenergic stimulation in the late phase of myocardial infarct healing
-
Nelson S.D., and Coyne K. Electrophysiologic effects of selective B1 adrenergic stimulation in the late phase of myocardial infarct healing. Int J Cardiol 36 (1992) 95-102
-
(1992)
Int J Cardiol
, vol.36
, pp. 95-102
-
-
Nelson, S.D.1
Coyne, K.2
-
59
-
-
0025944283
-
Polymorphous ventricular tachycardia associated with acute myocardial infarction
-
Wolfe C.L., Nibley C., Bhandari A., Chatterjee K., and Scheinman M. Polymorphous ventricular tachycardia associated with acute myocardial infarction. Circulation 84 (1991) 1543-1551
-
(1991)
Circulation
, vol.84
, pp. 1543-1551
-
-
Wolfe, C.L.1
Nibley, C.2
Bhandari, A.3
Chatterjee, K.4
Scheinman, M.5
-
60
-
-
0018583871
-
Polymorphous ventricular tachycardia: clinical features and treatment
-
Sclarovsky S., Strasberg B., Lewin R.F., and Agmon J. Polymorphous ventricular tachycardia: clinical features and treatment. Am J Cardiol 44 (1979) 339
-
(1979)
Am J Cardiol
, vol.44
, pp. 339
-
-
Sclarovsky, S.1
Strasberg, B.2
Lewin, R.F.3
Agmon, J.4
-
61
-
-
0023872278
-
Reentry as a cause of ventricular tachycardia in patients with chronic ischemic heart disease: electrophysiologic and anatomic correlation
-
DeBakker J.M.T., Van Capelle G.J.L., Janse M.J., Wilde A.A., Coronel R., Becker A.E., et al. Reentry as a cause of ventricular tachycardia in patients with chronic ischemic heart disease: electrophysiologic and anatomic correlation. Circulation 77 (1988) 589-606
-
(1988)
Circulation
, vol.77
, pp. 589-606
-
-
DeBakker, J.M.T.1
Van Capelle, G.J.L.2
Janse, M.J.3
Wilde, A.A.4
Coronel, R.5
Becker, A.E.6
-
62
-
-
0030671242
-
Sudden death in coronary artery disease: acute ischemia versus myocardial substrate
-
Mehta D., Curwin J., Gomes J.A., and Fuster V. Sudden death in coronary artery disease: acute ischemia versus myocardial substrate. Circulation 96 (1997) 3215-3223
-
(1997)
Circulation
, vol.96
, pp. 3215-3223
-
-
Mehta, D.1
Curwin, J.2
Gomes, J.A.3
Fuster, V.4
-
63
-
-
0025068779
-
Surgical coronary revascularization in survivors of prehospital cardiac arrest: its effect on inducible ventricular arrhythmias and long-term survival
-
Kelly P., Ruskin J.N., Vlahakes G.J., Buckley Jr. M.J., Freeman C.S., and Garan H. Surgical coronary revascularization in survivors of prehospital cardiac arrest: its effect on inducible ventricular arrhythmias and long-term survival. J Am Coll Cardiol 15 (1990) 267-273
-
(1990)
J Am Coll Cardiol
, vol.15
, pp. 267-273
-
-
Kelly, P.1
Ruskin, J.N.2
Vlahakes, G.J.3
Buckley Jr., M.J.4
Freeman, C.S.5
Garan, H.6
-
64
-
-
0023266257
-
Coronary bypass surgery in exercise induced ventricular tachycardia
-
Rasmussen K., Lunde P.I., and Lie M. Coronary bypass surgery in exercise induced ventricular tachycardia. Eur Heart J 8 (1987) 44
-
(1987)
Eur Heart J
, vol.8
, pp. 44
-
-
Rasmussen, K.1
Lunde, P.I.2
Lie, M.3
-
65
-
-
0026091044
-
Arrhythmogenic effects of graded coronary blood flow reduction superimposed upon prior myocardial infarction in dogs
-
Furukawa T., Moroe K., Mayrovitz H.N., Sampsell R., Furukawa N., and Myerburg R.J. Arrhythmogenic effects of graded coronary blood flow reduction superimposed upon prior myocardial infarction in dogs. Circulation 84 (1991) 368-377
-
(1991)
Circulation
, vol.84
, pp. 368-377
-
-
Furukawa, T.1
Moroe, K.2
Mayrovitz, H.N.3
Sampsell, R.4
Furukawa, N.5
Myerburg, R.J.6
-
66
-
-
0023853925
-
Spontaneous and electrically induced ventricular arrhythmias during acute ischemia superimposed on 2 week old canine myocardial infarction
-
Garan H., McComb J.M., and Ruskin J.N. Spontaneous and electrically induced ventricular arrhythmias during acute ischemia superimposed on 2 week old canine myocardial infarction. J Am Coll Cardiol 11 (1988) 603-611
-
(1988)
J Am Coll Cardiol
, vol.11
, pp. 603-611
-
-
Garan, H.1
McComb, J.M.2
Ruskin, J.N.3
-
67
-
-
0021150196
-
Safety of maximal exercise testing in patients at high risk for ventricular arrhythmia
-
Young D.Z., Lampert S., Graboys T.B., and Lown B. Safety of maximal exercise testing in patients at high risk for ventricular arrhythmia. Circulation 70 (1984) 184-191
-
(1984)
Circulation
, vol.70
, pp. 184-191
-
-
Young, D.Z.1
Lampert, S.2
Graboys, T.B.3
Lown, B.4
-
68
-
-
0023390791
-
Catecholamine-sensitive ventricular tachycardia
-
Vlay S.C. Catecholamine-sensitive ventricular tachycardia. Am Heart J 114 (1987) 455-461
-
(1987)
Am Heart J
, vol.114
, pp. 455-461
-
-
Vlay, S.C.1
-
69
-
-
0018912691
-
National survey of exercise stress testing facilities
-
Stuart Jr. R.J., and Ellestad M.H. National survey of exercise stress testing facilities. Chest 77 (1980) 94-97
-
(1980)
Chest
, vol.77
, pp. 94-97
-
-
Stuart Jr., R.J.1
Ellestad, M.H.2
-
70
-
-
0033859526
-
A survey of exercise testing: methods, utilization, interpretation, and safety in the VAHCS
-
Myers J., Voodi L., Umann T., and Froelicher V.F. A survey of exercise testing: methods, utilization, interpretation, and safety in the VAHCS. J Cardiopulm Rehabil 20 (2000) 251-258
-
(2000)
J Cardiopulm Rehabil
, vol.20
, pp. 251-258
-
-
Myers, J.1
Voodi, L.2
Umann, T.3
Froelicher, V.F.4
-
71
-
-
0027490709
-
Comparison of dobutamine stress echocardiography, dipyridamole stress echocardiography and exercise stress testing for diagnosis of coronary artery disease
-
Previtali M., Lanzarini L., Fetiveau R., Poli A., Ferrario M., Falcone C., et al. Comparison of dobutamine stress echocardiography, dipyridamole stress echocardiography and exercise stress testing for diagnosis of coronary artery disease. Am J Cardiol 72 (1993) 865-870
-
(1993)
Am J Cardiol
, vol.72
, pp. 865-870
-
-
Previtali, M.1
Lanzarini, L.2
Fetiveau, R.3
Poli, A.4
Ferrario, M.5
Falcone, C.6
-
72
-
-
0037099285
-
Functional and prognostic significance of exercise-induced ventricular arrhythmias in patients with suspected coronary artery disease
-
Elhendy A., Chandrasekaran K., Gersh B.J., Mahoney D., Burger K.N., and Pellikka P.A. Functional and prognostic significance of exercise-induced ventricular arrhythmias in patients with suspected coronary artery disease. Am J Cardiol 90 (2002) 95-100
-
(2002)
Am J Cardiol
, vol.90
, pp. 95-100
-
-
Elhendy, A.1
Chandrasekaran, K.2
Gersh, B.J.3
Mahoney, D.4
Burger, K.N.5
Pellikka, P.A.6
-
73
-
-
0028967875
-
Safety of dipyridamole testing in 73806 patients: the Multicenter Dipyridamole Safety Study
-
Lette J., Tatum J.L., Fraser S., Miller D.D., Waters D.D., Heller G., et al. Safety of dipyridamole testing in 73806 patients: the Multicenter Dipyridamole Safety Study. J Nucl Cardiol 2 (1995) 3-17
-
(1995)
J Nucl Cardiol
, vol.2
, pp. 3-17
-
-
Lette, J.1
Tatum, J.L.2
Fraser, S.3
Miller, D.D.4
Waters, D.D.5
Heller, G.6
-
74
-
-
0026634802
-
Safety of intravenous high-dose dipyridamole echocardiography. The Echo-Persantine International Cooperative Study Group
-
Picano E., Marini C., Pirelli S., Maffei S., Bolognese L., Chiriatti G., et al. Safety of intravenous high-dose dipyridamole echocardiography. The Echo-Persantine International Cooperative Study Group. Am J Cardiol 70 (1992) 252-258
-
(1992)
Am J Cardiol
, vol.70
, pp. 252-258
-
-
Picano, E.1
Marini, C.2
Pirelli, S.3
Maffei, S.4
Bolognese, L.5
Chiriatti, G.6
-
75
-
-
39349089910
-
Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: a position statement
-
Marcassa C., Bax J., Bengel F., Hesse B., Petersen C., Reyes E., et al. Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: a position statement. Eur Heart J 29 (2008) 557-563
-
(2008)
Eur Heart J
, vol.29
, pp. 557-563
-
-
Marcassa, C.1
Bax, J.2
Bengel, F.3
Hesse, B.4
Petersen, C.5
Reyes, E.6
|