메뉴 건너뛰기




Volumn 7, Issue 5, 2005, Pages 433-439

Sustained ventricular tachycardia induced by dobutamine stress echocardiography: A prospective study

Author keywords

Dobutamine stress echocardiography; Sustained ventricular tachycardia

Indexed keywords

ATROPINE; DOBUTAMINE;

EID: 23744461385     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1016/j.eupc.2005.05.009     Document Type: Article
Times cited : (12)

References (23)
  • 1
    • 0027190017 scopus 로고
    • Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients
    • H. Mertes S.G. Sawada T. Ryan et al. Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients Circulation 88 1993 15-19
    • (1993) Circulation , vol.88 , pp. 15-19
    • Mertes, H.1    Sawada, S.G.2    Ryan, T.3
  • 2
    • 0027959932 scopus 로고
    • Safety and tolerability of dobutamine-atropine stress echocardiography: A prospective, multicentre study
    • Echo Dobutamine International Cooperative Study Group
    • E. Picano W. Mathias Jr. A. Pingitore R. Bigi M. Previtali Safety and tolerability of dobutamine-atropine stress echocardiography: A prospective, multicentre study. Echo Dobutamine International Cooperative Study Group Lancet 344 1994 1190-1192
    • (1994) Lancet , vol.344 , pp. 1190-1192
    • Picano, E.1    Mathias, W.2    Pingitore, A.3    Bigi, R.4    Previtali, M.5
  • 3
    • 0028327160 scopus 로고
    • Safety of dobutamine-atropine stress echocardiography in patients with suspected or proven coronary artery disease
    • D. Poldermans P.M. Fioretti E. Boersma et al. Safety of dobutamine-atropine stress echocardiography in patients with suspected or proven coronary artery disease Am J Cardiol 73 1994 456-459
    • (1994) Am. J. Cardiol. , vol.73 , pp. 456-459
    • Poldermans, D.1    Fioretti, P.M.2    Boersma, E.3
  • 4
    • 0030958384 scopus 로고    scopus 로고
    • Evolution of dobutamine echocardiography protocols and indications: Safety and side effects in 3,011 studies over 5 years
    • M.A. Secknus T.H. Marwick Evolution of dobutamine echocardiography protocols and indications: Safety and side effects in 3,011 studies over 5 years J Am Coll Cardiol 29 1997 1234-1240
    • (1997) J. Am. Coll. Cardiol. , vol.29 , pp. 1234-1240
    • Secknus, M.A.1    Marwick, T.H.2
  • 5
    • 0032834445 scopus 로고    scopus 로고
    • Safety of dobutamine-atropine stress echocardiography: A prospective experience of 4,033 consecutive studies
    • W. Mathias Jr. A. Arruda F.C. Santos et al. Safety of dobutamine-atropine stress echocardiography: A prospective experience of 4,033 consecutive studies J Am Soc Echocardiogr 12 1999 785-791
    • (1999) J. Am. Soc. Echocardiogr. , vol.12 , pp. 785-791
    • Mathias Jr., W.1    Arruda, A.2    Santos, F.C.3
  • 6
    • 0030999884 scopus 로고    scopus 로고
    • Safety and accuracy of dobutamine-atropine stress echocardiography for the detection of residual stenosis of the infarct-related artery and multivessel disease during the first week after acute myocardial infarction
    • S.C. Smart T. Knickelbine T.R. Stoiber M. Carlos J.C. Wynsen K.B. Sagar Safety and accuracy of dobutamine-atropine stress echocardiography for the detection of residual stenosis of the infarct-related artery and multivessel disease during the first week after acute myocardial infarction Circulation 95 1997 1394-1401
    • (1997) Circulation , vol.95 , pp. 1394-1401
    • Smart, S.C.1    Knickelbine, T.2    Stoiber, T.R.3    Carlos, M.4    Wynsen, J.C.5    Sagar, K.B.6
  • 7
    • 0033975462 scopus 로고    scopus 로고
    • Safety and prognostic value of early dobutamine-atropine stress echocardiography in patients with spontaneous chest pain and a non-diagnostic electrocardiogram
    • M.L. Geleijnse A. Elhendy J.D. Kasprzak et al. Safety and prognostic value of early dobutamine-atropine stress echocardiography in patients with spontaneous chest pain and a non-diagnostic electrocardiogram Eur Heart J 21 2000 397-406
    • (2000) Eur. Heart J. , vol.21 , pp. 397-406
    • Geleijnse, M.L.1    Elhendy, A.2    Kasprzak, J.D.3
  • 8
    • 0029655748 scopus 로고    scopus 로고
    • Sustained nonischemic ventricular tachycardia during dobutamine stress echocardiography
    • E.C. Madu A. Price T. Harris H. Badran C. Rouse K.B. Ramanathan Sustained nonischemic ventricular tachycardia during dobutamine stress echocardiography Cardiology 87 1996 82-85
    • (1996) Cardiology , vol.87 , pp. 82-85
    • Madu, E.C.1    Price, A.2    Harris, T.3    Badran, H.4    Rouse, C.5    Ramanathan, K.B.6
  • 9
    • 0029548936 scopus 로고
    • Incidence and correlates of complex ventricular arrhythmias during dobutamine stress echocardiography after acute myocardial infarction
    • R. Bigi N. Partesana A. Verzoni et al. Incidence and correlates of complex ventricular arrhythmias during dobutamine stress echocardiography after acute myocardial infarction Eur Heart J 16 1995 1819-1824
    • (1995) Eur. Heart J. , vol.16 , pp. 1819-1824
    • Bigi, R.1    Partesana, N.2    Verzoni, A.3
  • 10
    • 0025209836 scopus 로고
    • Identification of viable myocardium by echocardiography during dobutamine infusion in patients with myocardial infarction after thrombolytic therapy: Comparison with positron emission tomography
    • L.A. Pierard C.M. De Landsheere C. Berthe P. Rigo H.E. Kulbertus Identification of viable myocardium by echocardiography during dobutamine infusion in patients with myocardial infarction after thrombolytic therapy: Comparison with positron emission tomography J Am Coll Cardiol 15 1990 1021-1031
    • (1990) J. Am. Coll. Cardiol. , vol.15 , pp. 1021-1031
    • Pierard, L.A.1    De Landsheere, C.M.2    Berthe, C.3    Rigo, P.4    Kulbertus, H.E.5
  • 11
    • 0028919118 scopus 로고
    • Stress echocardiography. Part II. Dobutamine stress echocardiography: Techniques, implementation, clinical applications and correlations
    • P.A. Pellikka V.L. Roger J.K. Oh F.A. Miller J.B. Seward A.J. Tajik Stress echocardiography. Part II. Dobutamine stress echocardiography: techniques, implementation, clinical applications and correlations Mayo Clin Proc 70 1995 16-27
    • (1995) Mayo Clin. Proc. , vol.70 , pp. 16-27
    • Pellikka, P.A.1    Roger, V.L.2    Oh, J.K.3    Miller, F.A.4    Seward, J.B.5    Tajik, A.J.6
  • 12
    • 0024723470 scopus 로고
    • Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms
    • N.B. Schiller P.M. Shah M. Crawford et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms J Am Soc Echocardiogr 2 1989 358-367
    • (1989) J. Am. Soc. Echocardiogr. , vol.2 , pp. 358-367
    • Schiller, N.B.1    Shah, P.M.2    Crawford, M.3
  • 13
    • 0001904433 scopus 로고    scopus 로고
    • The diagnosis of tachyarrhythmias
    • D.G. Julian A.J. Camm K.M. Fox R.J.C. Hall P.A. Poole-Wilson editors. 2nd ed. Saunders
    • A.J. Camm D. Katritsis The diagnosis of tachyarrhythmias In: D.G. Julian A.J. Camm K.M. Fox R.J.C. Hall P.A. Poole-Wilson editors. Heart disease 2nd ed. 1996 Saunders 606-621
    • (1996) Heart Disease , pp. 606-621
    • Camm, A.J.1    Katritsis, D.2
  • 14
    • 3042537823 scopus 로고    scopus 로고
    • Non-sustained ventricular tachycardia. Where do we stand?
    • D. Katritsis A.J. Camm Non-sustained ventricular tachycardia. Where do we stand? Eur Heart J 25 2004 1093-1099
    • (2004) Eur. Heart J. , vol.25 , pp. 1093-1099
    • Katritsis, D.1    Camm, A.J.2
  • 15
    • 0021823936 scopus 로고
    • Programmed electrical stimulation of the heart in ventricular arrhythmias
    • P. Brugada H.J. Wellens Programmed electrical stimulation of the heart in ventricular arrhythmias Am J Cardiol 56 1985 187-190
    • (1985) Am. J. Cardiol. , vol.56 , pp. 187-190
    • Brugada, P.1    Wellens, H.J.2
  • 16
    • 4444346401 scopus 로고    scopus 로고
    • Myocardial ischemia and induction of sustained ventricular tachyarrhythmias: Evaluation using dobutamine stress echocardiography-electrophysiologic testing
    • B.S. Stambler K.O. Akosah P.K. Mohanty M.A. Wood K.A. Ellenbogen Myocardial ischemia and induction of sustained ventricular tachyarrhythmias: Evaluation using dobutamine stress echocardiography-electrophysiologic testing J Cardiovasc Electrophysiol 15 2004 901-907
    • (2004) J. Cardiovasc. Electrophysiol. , vol.15 , pp. 901-907
    • Stambler, B.S.1    Akosah, K.O.2    Mohanty, P.K.3    Wood, M.A.4    Ellenbogen, K.A.5
  • 18
    • 0019446622 scopus 로고
    • Exercise-triggered paroxysmal ventricular tachycardia. A repetitive rhythmic activity possibly related to afterdepolarization
    • D. Wu H.C. Kou J.S. Hung Exercise-triggered paroxysmal ventricular tachycardia. A repetitive rhythmic activity possibly related to afterdepolarization Ann Intern Med 95 1981 410-414
    • (1981) Ann. Intern. Med. , vol.95 , pp. 410-414
    • Wu, D.1    Kou, H.C.2    Hung, J.S.3
  • 19
    • 0032932021 scopus 로고    scopus 로고
    • Ventricular tachycardia during dobutamine stress myocardial contrast imaging
    • D. Poldermans F.J. ten Cate A. Elhendy et al. Ventricular tachycardia during dobutamine stress myocardial contrast imaging Chest 115 1999 307-308
    • (1999) Chest , vol.115 , pp. 307-308
    • Poldermans, D.1    ten Cate, F.J.2    Elhendy, A.3
  • 20
    • 0037220370 scopus 로고    scopus 로고
    • Catecholaminergic polymorphic ventricular tachycardia: Electrocardiographic characteristics and optimal therapeutic strategies to prevent sudden death
    • N. Sumitomo K. Harada M. Nagashima et al. Catecholaminergic polymorphic ventricular tachycardia: Electrocardiographic characteristics and optimal therapeutic strategies to prevent sudden death Heart 89 2003 66-70
    • (2003) Heart , vol.89 , pp. 66-70
    • Sumitomo, N.1    Harada, K.2    Nagashima, M.3
  • 21
    • 0141571322 scopus 로고    scopus 로고
    • Ryanodine receptor mutations associated with stress-induced ventricular tachycardia mediate increased calcium release in stimulated cardiomyocytes
    • C.H. George G.V. Higgs F.A. Lai Ryanodine receptor mutations associated with stress-induced ventricular tachycardia mediate increased calcium release in stimulated cardiomyocytes Circ Res 93 2003 531-540
    • (2003) Circ. Res. , vol.93 , pp. 531-540
    • George, C.H.1    Higgs, G.V.2    Lai, F.A.3
  • 22
    • 0017689665 scopus 로고
    • Predictive implications of ventricular premature contractions associated with treadmill stress testing
    • J.A. Udall M.H. Ellestad Predictive implications of ventricular premature contractions associated with treadmill stress testing Circulation 56 1977 985-989
    • (1977) Circulation , vol.56 , pp. 985-989
    • Udall, J.A.1    Ellestad, M.H.2
  • 23
    • 0034699625 scopus 로고    scopus 로고
    • Long-term outcome in asymptomatic men with exercise-induced premature ventricular depolarizations
    • X. Jouven M. Zureik M. Desnos D. Courbon P. Ducimetiere Long-term outcome in asymptomatic men with exercise-induced premature ventricular depolarizations N Engl J Med 343 2000 826-833
    • (2000) N. Engl. J. Med. , vol.343 , pp. 826-833
    • Jouven, X.1    Zureik, M.2    Desnos, M.3    Courbon, D.4    Ducimetiere, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.