메뉴 건너뛰기




Volumn 131, Issue 1, 2008, Pages 100-109

DOSIMAP: A high-resolution 2-D tissue equivalent dosemeter for linac QA and IMRT verification

Author keywords

[No Author keywords available]

Indexed keywords

POLYSTYRENE;

EID: 56349121147     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncn228     Document Type: Conference Paper
Times cited : (6)

References (18)
  • 3
    • 33947408376 scopus 로고    scopus 로고
    • Schreiner, L. J. Dosimetry in Modern Radiation Therapy: Limitations and Need. J. Phys., Conference Series, 56, 1-13 (2006).
    • Schreiner, L. J. Dosimetry in Modern Radiation Therapy: Limitations and Need. J. Phys., Conference Series, 56, 1-13 (2006).
  • 4
    • 33947400267 scopus 로고    scopus 로고
    • Jordan, K. Review of recent advances in non gel dosimetry. J. Phys., Conference Series, 56, 132-141 (2006).
    • Jordan, K. Review of recent advances in non gel dosimetry. J. Phys., Conference Series, 56, 132-141 (2006).
  • 5
    • 0036703563 scopus 로고    scopus 로고
    • Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by static multileaf collimator
    • Zhu, X. R., Jursinic, P. A., Grimm, D. F., Lopez, F., Rownd, J. J. and Gillin, M. T. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by static multileaf collimator. Med. Phys. 29, 1687-1692 (2002).
    • (2002) Med. Phys , vol.29 , pp. 1687-1692
    • Zhu, X.R.1    Jursinic, P.A.2    Grimm, D.F.3    Lopez, F.4    Rownd, J.J.5    Gillin, M.T.6
  • 7
    • 33947400268 scopus 로고    scopus 로고
    • Oldham, M. 3D dosimetry by optical CT scanning. J. Phys., Conference Series, 56, 58-71 (2006).
    • Oldham, M. 3D dosimetry by optical CT scanning. J. Phys., Conference Series, 56, 58-71 (2006).
  • 9
    • 1542603236 scopus 로고    scopus 로고
    • Evaluation of a 2D diode array for IMRT quality assurance
    • Letourneau, D., Gulam, M., Yan, D., Oldham, M. and Wong, J. W. Evaluation of a 2D diode array for IMRT quality assurance. Radiother Oncol 70(2), 199-206 (2003).
    • (2003) Radiother Oncol , vol.70 , Issue.2 , pp. 199-206
    • Letourneau, D.1    Gulam, M.2    Yan, D.3    Oldham, M.4    Wong, J.W.5
  • 11
    • 0026804696 scopus 로고
    • Water equivalent plastic scintillators detectors for high energy beam dosimetry: Part I physical characteristics and technical considerations
    • Beddar, A. S., Mackie, T. R. and Mattix, F. H. Water equivalent plastic scintillators detectors for high energy beam dosimetry: Part I physical characteristics and technical considerations. Phys. Med. Biol. 37, 1883-1900 (1992).
    • (1992) Phys. Med. Biol , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    Mackie, T.R.2    Mattix, F.H.3
  • 12
    • 56349120663 scopus 로고    scopus 로고
    • Plastic scintillator dosimetry: Optimal selection of scintillating fibers and scintillators
    • Archambauld, L., Arsenau, J., Gringas, L., Beddar, A. S., Roy, R. and Beaulieu, L. Plastic scintillator dosimetry: Optimal selection of scintillating fibers and scintillators, Med. Phys. 32, 3750-3754 (2005).
    • (2005) Med. Phys , vol.32 , pp. 3750-3754
    • Archambauld, L.1    Arsenau, J.2    Gringas, L.3    Beddar, A.S.4    Roy, R.5    Beaulieu, L.6
  • 14
    • 31044441058 scopus 로고    scopus 로고
    • Development and characterization of a tissue equivalent scintillator based dosimetry system
    • Petric, M. P., Robar, J. L. and Clark, B. Development and characterization of a tissue equivalent scintillator based dosimetry system. Med. Phys. 33, 96-105 (2006).
    • (2006) Med. Phys , vol.33 , pp. 96-105
    • Petric, M.P.1    Robar, J.L.2    Clark, B.3
  • 15
    • 42949134259 scopus 로고    scopus 로고
    • The DOSIMAP, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cenrekov discrimination methods
    • Frelin, A. M., Fontbonne, J. M., Ban, G., Colin, J., Labalme, M., Batalla, A., Vela, A., Boher, P., Braud, M. and Leroux, T. The DOSIMAP, a new 2D scintillating dosimeter for IMRT quality assurance: characterization of two Cenrekov discrimination methods. Med. Phys. 35(5), 1651-1662 (2008).
    • (2008) Med. Phys , vol.35 , Issue.5 , pp. 1651-1662
    • Frelin, A.M.1    Fontbonne, J.M.2    Ban, G.3    Colin, J.4    Labalme, M.5    Batalla, A.6    Vela, A.7    Boher, P.8    Braud, M.9    Leroux, T.10
  • 17
    • 56349170746 scopus 로고    scopus 로고
    • Leroux, T. and Boher, P. Device and method for discriminating Cerenkov and scintillation radiation. WO2007/131771 (2006).
    • Leroux, T. and Boher, P. Device and method for discriminating Cerenkov and scintillation radiation. WO2007/131771 (2006).
  • 18
    • 84907513176 scopus 로고
    • Tissue Substitutes in Radiation Dosimetry and Measurement
    • International Commission on Radiation Units and Measurements, Bethesda, MD, USA
    • International Commission on Radiation Units and Measurements. Tissue Substitutes in Radiation Dosimetry and Measurement. ICRU Report 44 (Bethesda, MD, USA) (1989).
    • (1989) ICRU Report , vol.44


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.