메뉴 건너뛰기




Volumn , Issue , 2007, Pages

A critical comparison of existing ventilation rate determination techniques for building openings and prospects for future

Author keywords

Air flow; Anemometers; Measurement; Natural ventilation; Tracer gas

Indexed keywords

AIR POLLUTION; AIR QUALITY; BUILDINGS; ELECTRONIC EQUIPMENT TESTING; WASTE MANAGEMENT;

EID: 56349120727     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (30)
  • 1
    • 0032724168 scopus 로고    scopus 로고
    • Computational study of natural ventilation
    • Ayad, S.S. 1999. Computational study of natural ventilation, J Wind Eng Ind Aerod. 82(1-3): 49-68.
    • (1999) J Wind Eng Ind Aerod , vol.82 , Issue.1-3 , pp. 49-68
    • Ayad, S.S.1
  • 2
    • 85016442595 scopus 로고
    • Sensor for continuous ventilating rate measurement in Livestock Buildings
    • Berckmans, D., Vandenbroeck, P. and Goedseels, V. 1991. Sensor for continuous ventilating rate measurement in Livestock Buildings. Indoor Air, 3 : 323-336.
    • (1991) Indoor Air , vol.3 , pp. 323-336
    • Berckmans, D.1    Vandenbroeck, P.2    Goedseels, V.3
  • 3
    • 0001840252 scopus 로고
    • Modelling of air exchange rate in a greenhouse equipped with continuous roof vents
    • Boulard, T. and Baille, A. 1995. Modelling of air exchange rate in a greenhouse equipped with continuous roof vents. J Agr. Eng Res. 61: 37-48.
    • (1995) J Agr. Eng Res , vol.61 , pp. 37-48
    • Boulard, T.1    Baille, A.2
  • 4
    • 0035358697 scopus 로고    scopus 로고
    • Effect of wall roughness changes on ultrasonic gas flowmeters
    • Calogirou, A., Boekhoven, J. and Henkes, R.A.W.M. 2001. Effect of wall roughness changes on ultrasonic gas flowmeters. Flow Meas Instrum, 12(3): 219-229.
    • (2001) Flow Meas Instrum , vol.12 , Issue.3 , pp. 219-229
    • Calogirou, A.1    Boekhoven, J.2    Henkes, R.A.W.M.3
  • 5
    • 0037242094 scopus 로고    scopus 로고
    • Determination of greenhouse-specific aspects of ventilation using three-dimensional computational fluid dynamics
    • Campen, J.B. and Bot, G.P.A. 2003. Determination of greenhouse-specific aspects of ventilation using three-dimensional computational fluid dynamics. Biosys Eng. 84(1): 69-77.
    • (2003) Biosys Eng , vol.84 , Issue.1 , pp. 69-77
    • Campen, J.B.1    Bot, G.P.A.2
  • 6
    • 3042600545 scopus 로고    scopus 로고
    • Ventilation performance measurement using constant concentration dosing strategy
    • Chao, C.Y., Wan, M.P. and. Law, A. K. 2004. Ventilation performance measurement using constant concentration dosing strategy. Build Environ 39: 1277-1288.
    • (2004) Build Environ , vol.39 , pp. 1277-1288
    • Chao, C.Y.1    Wan, M.P.2    Law, A.K.3
  • 7
    • 0002550578 scopus 로고    scopus 로고
    • Assessment of techniques for measuring the ventilation rate, using an experimental building section
    • Demmers, T. G. M., Burgess, L. R., Phillips, V. R., Clark, J. A. and Wathes, C. M. 2000. Assessment of techniques for measuring the ventilation rate, using an experimental building section, J Agr Eng Res. 76(1): 71-81.
    • (2000) J Agr Eng Res , vol.76 , Issue.1 , pp. 71-81
    • Demmers, T.G.M.1    Burgess, L.R.2    Phillips, V.R.3    Clark, J.A.4    Wathes, C.M.5
  • 10
    • 0032647807 scopus 로고    scopus 로고
    • COMIS - an international multizone air-flow and contaminant transport model
    • Feustel, H.E. 1999. COMIS - an international multizone air-flow and contaminant transport model, Energ Build. 30(1): 3-18.
    • (1999) Energ Build , vol.30 , Issue.1 , pp. 3-18
    • Feustel, H.E.1
  • 11
    • 0032097570 scopus 로고    scopus 로고
    • Natural ventilation for passive cooling: Measurement of discharge coefficients
    • Flourentzou, F., Van der Maas, J., Roulet, C.-A. 1998. Natural ventilation for passive cooling: measurement of discharge coefficients. Energ Buildings. 27: 283-292.
    • (1998) Energ Buildings , vol.27 , pp. 283-292
    • Flourentzou, F.1    Van der Maas, J.2    Roulet, C.-A.3
  • 12
    • 0026139671 scopus 로고
    • Mapping flow fields with a heated wire and an infrared imaging system
    • Gartenberg, E.and Roberts, A.S. 1990. Mapping flow fields with a heated wire and an infrared imaging system. J. Aircraft, Vol.28, No 2, pp 284-286.
    • (1990) J. Aircraft , vol.28 , Issue.2 , pp. 284-286
    • Gartenberg, E.1    Roberts, A.S.2
  • 13
    • 31144461378 scopus 로고    scopus 로고
    • Experimental investigation of air flow and temperature distribution in deep urban canyons for natural ventilation purposes
    • Georgakis, Ch. and Santamouris, M. 2006. Experimental investigation of air flow and temperature distribution in deep urban canyons for natural ventilation purposes. Energ Build. 38: 367-376.
    • (2006) Energ Build , vol.38 , pp. 367-376
    • Georgakis, C.1    Santamouris, M.2
  • 15
    • 0030234309 scopus 로고    scopus 로고
    • Analysis of installation effects by means of computational fluid dynamics - CFD vs experiments?, Flow Measurement and Instrumentation
    • Hilgenstock, A. and Ernst, R. 1996. Analysis of installation effects by means of computational fluid dynamics - CFD vs experiments?, Flow Measurement and Instrumentation, Opt Method Flow Meas. 7 (3-4): 161-171.
    • (1996) Opt Method Flow Meas , vol.7 , Issue.3-4 , pp. 161-171
    • Hilgenstock, A.1    Ernst, R.2
  • 16
    • 0000919544 scopus 로고    scopus 로고
    • A comprehensive experimental study of aerial pollutants in and emissions from livestock buildings. Part 1: Methods
    • Hinz, T. and Linke, S. 1998. A comprehensive experimental study of aerial pollutants in and emissions from livestock buildings. Part 1: Methods, J Agr Eng Res. 70 (1): 111-118.
    • (1998) J Agr Eng Res , vol.70 , Issue.1 , pp. 111-118
    • Hinz, T.1    Linke, S.2
  • 17
    • 0036646238 scopus 로고    scopus 로고
    • Simultaneous measurements of all three components of velocity and vorticity vectors in a lobed jet flow by means of dual-plane stereoscopic particle image velocimetry
    • Hu, H., Saga, T., Kobayashi, T. and Taniguchi, N. 2002. Simultaneous measurements of all three components of velocity and vorticity vectors in a lobed jet flow by means of dual-plane stereoscopic particle image velocimetry. Phys Fluids, 14 (7): 2128-2138.
    • (2002) Phys Fluids , vol.14 , Issue.7 , pp. 2128-2138
    • Hu, H.1    Saga, T.2    Kobayashi, T.3    Taniguchi, N.4
  • 18
    • 0030198115 scopus 로고    scopus 로고
    • Prediction of air temperature distribution in buildings with a zonal model
    • Inard, C., Bouia, H. and Dalicieux, P. 1996. Prediction of air temperature distribution in buildings with a zonal model, Energ Build. 24 (2): 125-132.
    • (1996) Energ Build , vol.24 , Issue.2 , pp. 125-132
    • Inard, C.1    Bouia, H.2    Dalicieux, P.3
  • 19
    • 0037360877 scopus 로고    scopus 로고
    • Buoyancy-driven single-sided natural ventilation in buildings with large openings
    • Jiang, Y. and Chen, Q. 2003. Buoyancy-driven single-sided natural ventilation in buildings with large openings. Int J Heat Mass Tran. 46(6): 973-988.
    • (2003) Int J Heat Mass Tran , vol.46 , Issue.6 , pp. 973-988
    • Jiang, Y.1    Chen, Q.2
  • 20
    • 0346816587 scopus 로고    scopus 로고
    • Characterization of fugitive mercury emissions from the cell building at a US chlor-alkali plant
    • Kinsey, J.S., Swift, J. and Bursey, J. 2004. Characterization of fugitive mercury emissions from the cell building at a US chlor-alkali plant, Atmos Environ. 38 (4): 623-631.
    • (2004) Atmos Environ , vol.38 , Issue.4 , pp. 623-631
    • Kinsey, J.S.1    Swift, J.2    Bursey, J.3
  • 21
    • 18844382690 scopus 로고    scopus 로고
    • The effect of the use of openings on interzonal air flows in buildings: An experimental and simulation approach
    • Koinakis, C.J. 2005. The effect of the use of openings on interzonal air flows in buildings: an experimental and simulation approach. Energ Build. 37: 813-823.
    • (2005) Energ Build , vol.37 , pp. 813-823
    • Koinakis, C.J.1
  • 22
    • 0037401854 scopus 로고    scopus 로고
    • Natural ventilation of light well in high-rise apartment building
    • Kotani, H., Satoh, R. and Yamanaka, T. 2003. Natural ventilation of light well in high-rise apartment building, Energ Build. 35(4): 427-434.
    • (2003) Energ Build , vol.35 , Issue.4 , pp. 427-434
    • Kotani, H.1    Satoh, R.2    Yamanaka, T.3
  • 23
    • 56349164784 scopus 로고    scopus 로고
    • The accuracy of computational simulation for naturally ventilated multi-span greenhouse
    • Chicago, IL
    • Lee, I, Sase, S., Okushima, L., Ikeguchi, A., and Park, W. 2002. The accuracy of computational simulation for naturally ventilated multi-span greenhouse. 2002 ASAE Annual Meeting. Chicago, IL.
    • (2002) ASAE Annual Meeting , pp. 2002
    • Lee, I.1    Sase, S.2    Okushima, L.3    Ikeguchi, A.4    Park, W.5
  • 24
    • 0034008868 scopus 로고    scopus 로고
    • Prediction of natural ventilation in buildings with large openings
    • Li, Y., Delsante, A. and Symons, J. 2000. Prediction of natural ventilation in buildings with large openings. Build Environ. 35(3): 191-206.
    • (2000) Build Environ , vol.35 , Issue.3 , pp. 191-206
    • Li, Y.1    Delsante, A.2    Symons, J.3
  • 27
    • 0021897550 scopus 로고
    • A quantitative estimate of the accuracy of tracer gas methods for the determination of the ventilation flow rate in buildings
    • Sandberg, M. and Blomqvist, C. 1985. A quantitative estimate of the accuracy of tracer gas methods for the determination of the ventilation flow rate in buildings, Build Environ. 20(3): 139-150.
    • (1985) Build Environ , vol.20 , Issue.3 , pp. 139-150
    • Sandberg, M.1    Blomqvist, C.2
  • 28
    • 23844512838 scopus 로고    scopus 로고
    • Application of integrating multi-zone model with CFD simulation to natural ventilation prediction
    • Tan, G. and Glicksman, L.R. 2005. Application of integrating multi-zone model with CFD simulation to natural ventilation prediction. Energ Buildings 37: 1049-1057.
    • (2005) Energ Buildings , vol.37 , pp. 1049-1057
    • Tan, G.1    Glicksman, L.R.2
  • 30
    • 0037365219 scopus 로고    scopus 로고
    • Nonlinear coupling between thermal mass and natural ventilation in buildings
    • Yam, J., Li, Y. and Zheng, Z. 2003. Nonlinear coupling between thermal mass and natural ventilation in buildings, Int J Heat Mass Tran. 46(7): 1251-1264.
    • (2003) Int J Heat Mass Tran , vol.46 , Issue.7 , pp. 1251-1264
    • Yam, J.1    Li, Y.2    Zheng, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.