메뉴 건너뛰기




Volumn 35, Issue 4, 2003, Pages 427-434

Natural ventilation of light well in high-rise apartment building

Author keywords

High rise apartment building; Light well; Stack effect; Wind tunnel test; Wind induced ventilation

Indexed keywords

COMPUTATIONAL FLUID DYNAMICS; EXHAUST GASES; TEMPERATURE DISTRIBUTION; VENTILATION; WATER HEATERS; WIND TUNNELS;

EID: 0037401854     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0378-7788(02)00166-4     Document Type: Article
Times cited : (44)

References (16)
  • 2
    • 0002539584 scopus 로고
    • Wind tunnel experiment on the natural ventilation of the court of a high rise residential building (in Japanese)
    • S. Hayakawa, Wind Tunnel Experiment on the Natural Ventilation of the Court of a High Rise Residential Building (in Japanese), in: Summaries of Technical Papers of Annual Meeting AIJ, vol. D, 1988, pp. 891-892.
    • (1988) Summaries of Technical Papers of Annual Meeting AIJ , vol.D , pp. 891-892
    • Hayakawa, S.1
  • 3
    • 0002337067 scopus 로고
    • Wind tunnel experiments on the air change rate of the court space of a tall building (in Japanese)
    • N. Kobayashi, Wind Tunnel Experiments on the Air Change Rate of the Court Space of a Tall Building (in Japanese), in: Summaries of Technical Papers of Annual Meeting AIJ, vol. D, 1989, pp. 511-512.
    • (1989) Summaries of Technical Papers of Annual Meeting AIJ , vol.D , pp. 511-512
    • Kobayashi, N.1
  • 4
    • 0012709459 scopus 로고    scopus 로고
    • Natural ventilation characteristics of courtyard buildings in Singapore
    • Reading, UK
    • N.H. Wong, H. Feriadi, K.W. Tham, C. Sekhar, K.W. Cheong, Natural Ventilation Characteristics of Courtyard Buildings in Singapore, in: Proceedings of ROOMVENT2000, vol. 2, Reading, UK, 2000, pp. 1213-1218.
    • (2000) Proceedings of ROOMVENT2000 , vol.2 , pp. 1213-1218
    • Wong, N.H.1    Feriadi, H.2    Tham, K.W.3    Sekhar, C.4    Cheong, K.W.5
  • 5
    • 0000220009 scopus 로고    scopus 로고
    • Ventilation behavior in a void space furnished with gas water-heaters
    • Yokohama, Japan
    • N. Ohira, T. Omori, Ventilation Behavior in a Void Space Furnished with Gas Water-heaters, in: Proceedings of ROOMVENT96, vol. 3, Yokohama, Japan, 1996, pp. 255-262.
    • (1996) Proceedings of ROOMVENT96 , vol.3 , pp. 255-262
    • Ohira, N.1    Omori, T.2
  • 6
    • 0000083248 scopus 로고    scopus 로고
    • Prediction of on-coil temperature of condensers installed at tall building re-entrant
    • Chow T.T., Lin Z. Prediction of on-coil temperature of condensers installed at tall building re-entrant. Applied Thermal Engineering. 19:1999;117-132.
    • (1999) Applied Thermal Engineering , vol.19 , pp. 117-132
    • Chow, T.T.1    Lin, Z.2
  • 7
    • 0033752061 scopus 로고    scopus 로고
    • Effect of building re-entrant shape on performance of air-cooled condensing units
    • Chow T.T., Lin Z., Wang Q.W. Effect of building re-entrant shape on performance of air-cooled condensing units. Energy and Buildings. 32:2000;143-152.
    • (2000) Energy and Buildings , vol.32 , pp. 143-152
    • Chow, T.T.1    Lin, Z.2    Wang, Q.W.3
  • 8
    • 0035372254 scopus 로고    scopus 로고
    • Flow analysis of condenser cooling air delivery via building light well
    • Chow T.T., Lin Z., Wang Q.W. Flow analysis of condenser cooling air delivery via building light well. Applied Thermal Engineering. 21:2001;831-843.
    • (2001) Applied Thermal Engineering , vol.21 , pp. 831-843
    • Chow, T.T.1    Lin, Z.2    Wang, Q.W.3
  • 9
    • 0036497476 scopus 로고    scopus 로고
    • Effect of condensing unit layout at building re-entrant shape on split-type air-conditioner performance
    • Chow T.T., Lin Z., Wang Q.W. Effect of condensing unit layout at building re-entrant shape on split-type air-conditioner performance. Energy and Buildings. 34:2002;237-244.
    • (2002) Energy and Buildings , vol.34 , pp. 237-244
    • Chow, T.T.1    Lin, Z.2    Wang, Q.W.3
  • 10
    • 0035451232 scopus 로고    scopus 로고
    • Flow and temperature outside a high-rise residential building due to heat rejection by its air-conditioners
    • Bojic M., Lee M., Yik F. Flow and temperature outside a high-rise residential building due to heat rejection by its air-conditioners. Energy and Buildings. 33:2001;737-751.
    • (2001) Energy and Buildings , vol.33 , pp. 737-751
    • Bojic, M.1    Lee, M.2    Yik, F.3
  • 11
    • 0036027682 scopus 로고    scopus 로고
    • Influence of a depth of a recessed space to flow due to air-conditioner heat rejection
    • Bojic M., Lee M., Yik F. Influence of a depth of a recessed space to flow due to air-conditioner heat rejection. Energy and Buildings. 34:2002;33-43.
    • (2002) Energy and Buildings , vol.34 , pp. 33-43
    • Bojic, M.1    Lee, M.2    Yik, F.3
  • 12
    • 0000324501 scopus 로고    scopus 로고
    • Natural ventilation caused by stack effect in large courtyard of high-rise building
    • Yokohama, Japan
    • Kotani, M. Narasaki, R. Satoh, T. Yamanaka, Natural Ventilation Caused by Stack Effect in Large Courtyard of High-Rise Building, in: Proceedings of ROOMVENT96, vol. 2, Yokohama, Japan, 1996, pp. 299-306.
    • (1996) Proceedings of ROOMVENT96 , vol.2 , pp. 299-306
    • Kotani, H.1    Narasaki, M.2    Satoh, R.3    Yamanaka, T.4
  • 14
    • 0012709461 scopus 로고    scopus 로고
    • Wind-induced ventilation of light well in high-rise apartment building - Influence of bottom opening condition on airflow rate
    • Reading, UK
    • H. Kotani, R. Sato, T. Yamanaka, Wind-induced Ventilation of Light Well in High-rise Apartment Building - Influence of Bottom Opening Condition on Airflow Rate, in: Proceedings of ROOMVENT2000, vol. 2, Reading, UK, 2000, pp. 1111-1116.
    • (2000) Proceedings of ROOMVENT2000 , vol.2 , pp. 1111-1116
    • Kotani, H.1    Sato, R.2    Yamanaka, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.