메뉴 건너뛰기




Volumn 2, Issue 3, 2008, Pages 184-192

Active high power conversion efficiency rectifier with built-in dual-mode back telemetry in standard CMOS technology

Author keywords

Back telemetry; CMOS; Full wave rectifier; Implantable microelectronic devices; Inductive link; Radio frequency identification (RFID); Wireless

Indexed keywords

CMOS INTEGRATED CIRCUITS; CONVERSION EFFICIENCY; DC GENERATORS; RADIO; RADIO FREQUENCY IDENTIFICATION (RFID); RADIO WAVES; SILICON; TELEMETERING EQUIPMENT;

EID: 56349085525     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2008.924444     Document Type: Conference Paper
Times cited : (47)

References (25)
  • 1
    • 4544328738 scopus 로고    scopus 로고
    • An inductive power system with integrated bidirectional data-transmission
    • M. Catrysse, B. Hermans, and R. Puers, "An inductive power system with integrated bidirectional data-transmission," Sens. Actuators A, vol. 115, pp. 221-229, 2004.
    • (2004) Sens. Actuators A , vol.115 , pp. 221-229
    • Catrysse, M.1    Hermans, B.2    Puers, R.3
  • 2
    • 77955074686 scopus 로고    scopus 로고
    • A wireless implantable multichannel microstimulating system-on-a-chip with modular architecture
    • Sep
    • M. Ghovanloo and K. Najafi, "A wireless implantable multichannel microstimulating system-on-a-chip with modular architecture," IEEE Trans. Neural Sys. Rehab. Engg., vol. 15, no. 3, pp. 449-457, Sep. 2007.
    • (2007) IEEE Trans. Neural Sys. Rehab. Engg , vol.15 , Issue.3 , pp. 449-457
    • Ghovanloo, M.1    Najafi, K.2
  • 4
    • 34648834153 scopus 로고    scopus 로고
    • Transcutaneous magnetic coupling of power and data
    • M. Akay, Ed. Hoboken, NJ: Wiley
    • M. Ghovanloo and G. Lazzi, "Transcutaneous magnetic coupling of power and data," in Wiley Encyclopedia of Biomedical Engineering, M. Akay, Ed. Hoboken, NJ: Wiley, 2006.
    • (2006) Wiley Encyclopedia of Biomedical Engineering
    • Ghovanloo, M.1    Lazzi, G.2
  • 6
    • 0029270102 scopus 로고
    • A low-power transponder IC for high-performance identification systems
    • Mar
    • U. Kaiser and W. Steinhaugen, "A low-power transponder IC for high-performance identification systems," IEEE J. Solid-State Circuits, vol. 30, no. 3, pp. 306-310, Mar. 1995.
    • (1995) IEEE J. Solid-State Circuits , vol.30 , Issue.3 , pp. 306-310
    • Kaiser, U.1    Steinhaugen, W.2
  • 7
    • 0035391629 scopus 로고    scopus 로고
    • A new contactless smart card IC using an on-chip antenna and an asynchronous microcontroller
    • Jul
    • A. Abrial, J. Bouvier, M. Renaudin, P. Senn, and P. Vivet, "A new contactless smart card IC using an on-chip antenna and an asynchronous microcontroller," IEEE J. Solid-State Circuits, vol. 36, no. 7, pp. 1101-1107, Jul. 2001.
    • (2001) IEEE J. Solid-State Circuits , vol.36 , Issue.7 , pp. 1101-1107
    • Abrial, A.1    Bouvier, J.2    Renaudin, M.3    Senn, P.4    Vivet, P.5
  • 8
    • 0141886007 scopus 로고    scopus 로고
    • Fully integrated passive UHF RFID transponder IC with 16.7- μW minimum RF input power
    • Oct
    • U. Karthaus and M. Fischer, "Fully integrated passive UHF RFID transponder IC with 16.7- μW minimum RF input power," IEEE J. Solid-State Circuits, vol. 38, no. 10, pp. 1602-1608, Oct. 2003.
    • (2003) IEEE J. Solid-State Circuits , vol.38 , Issue.10 , pp. 1602-1608
    • Karthaus, U.1    Fischer, M.2
  • 9
    • 14044253472 scopus 로고    scopus 로고
    • A wireless microsystem for the remote sensing of pressure, temperature, and relative humidity
    • Feb
    • A. D. DeHennis and K. D. Wise, "A wireless microsystem for the remote sensing of pressure, temperature, and relative humidity," IEEE J. Microelectromech. Syst., vol. 14, no. 1, pp. 12-22, Feb. 2005.
    • (2005) IEEE J. Microelectromech. Syst , vol.14 , Issue.1 , pp. 12-22
    • DeHennis, A.D.1    Wise, K.D.2
  • 10
    • 33645136169 scopus 로고    scopus 로고
    • Remote RF powering system for wireless MEMS strain sensors
    • Apr
    • N. Chaimanonart and D. J. Young, "Remote RF powering system for wireless MEMS strain sensors," IEEE J. Sens., vol. 6, no. 2, pp. 484-489, Apr. 2006.
    • (2006) IEEE J. Sens , vol.6 , Issue.2 , pp. 484-489
    • Chaimanonart, N.1    Young, D.J.2
  • 11
    • 10944259963 scopus 로고    scopus 로고
    • A wideband frequency shift keying wireless link for inductively powered biomedical implants
    • Dec
    • M. Ghovanloo and K. Najafi, "A wideband frequency shift keying wireless link for inductively powered biomedical implants," IEEE Trans. Circuits Syst. I, Reg. Papers, vol. 51, no. 12, pp. 2374-2383, Dec. 2004.
    • (2004) IEEE Trans. Circuits Syst. I, Reg. Papers , vol.51 , Issue.12 , pp. 2374-2383
    • Ghovanloo, M.1    Najafi, K.2
  • 12
    • 36348966760 scopus 로고    scopus 로고
    • A wideband power-efficient inductive wireless link for implantable microelectronic devices using multiple carriers
    • Oct
    • M. Ghovanloo and S. Atluri, "A wideband power-efficient inductive wireless link for implantable microelectronic devices using multiple carriers," IEEE Trans. Circuits Syst. I, Reg. Papers, vol. 54, no. 10, pp. 2211-2221, Oct. 2007.
    • (2007) IEEE Trans. Circuits Syst. I, Reg. Papers , vol.54 , Issue.10 , pp. 2211-2221
    • Ghovanloo, M.1    Atluri, S.2
  • 13
    • 0029294148 scopus 로고
    • Data transmission from an implantable biotelemeter by load-shift keying using circuit configuration modulator
    • May
    • Z. Tang, B. Smith, J. H. Schild, and P. H. Peckham, "Data transmission from an implantable biotelemeter by load-shift keying using circuit configuration modulator," IEEE Trans. Biomed. Eng., vol. 42, no. 5, pp. 524-528, May 1995.
    • (1995) IEEE Trans. Biomed. Eng , vol.42 , Issue.5 , pp. 524-528
    • Tang, Z.1    Smith, B.2    Schild, J.H.3    Peckham, P.H.4
  • 14
    • 39549085491 scopus 로고    scopus 로고
    • On-chip active power rectifiers for biomedical applications
    • T. Lehmann and Y. Moghe, "On-chip active power rectifiers for biomedical applications," in Proc. ISCAS IEEE Int. Symp. Circuits Syst., 2005, vol. 1, pp. 732-735.
    • (2005) Proc. ISCAS IEEE Int. Symp. Circuits Syst , vol.1 , pp. 732-735
    • Lehmann, T.1    Moghe, Y.2
  • 15
    • 33947410808 scopus 로고    scopus 로고
    • Integrated low-loss CMOS active rectfier for wirelessly powered devices
    • Dec
    • Y. H. Lam, W. H. Ki, and C. Y. Tsui, "Integrated low-loss CMOS active rectfier for wirelessly powered devices," IEEE Trans. Circuits Syst. II, Exp. Briefs, vol. 53, no. 12, pp. 1378-1382, Dec. 2006.
    • (2006) IEEE Trans. Circuits Syst. II, Exp. Briefs , vol.53 , Issue.12 , pp. 1378-1382
    • Lam, Y.H.1    Ki, W.H.2    Tsui, C.Y.3
  • 17
    • 34548359161 scopus 로고    scopus 로고
    • Efficiency enhanced CMOS rectifier for wireless telemetry
    • Aug. 31
    • C. L. Chen, K. H. Chen, and S. I. Liu, "Efficiency enhanced CMOS rectifier for wireless telemetry," Electron. Lett., vol. 43, no. 18, Aug. 31, 2007.
    • (2007) Electron. Lett , vol.43 , Issue.18
    • Chen, C.L.1    Chen, K.H.2    Liu, S.I.3
  • 18
    • 27744493038 scopus 로고    scopus 로고
    • Thermal effects of bioimplants
    • Sep
    • G. Lazzi, "Thermal effects of bioimplants," IEEE Eng. Med. Biol. Mag., vol. 24, no. 5, pp. 75-81, Sep. 2005.
    • (2005) IEEE Eng. Med. Biol. Mag , vol.24 , Issue.5 , pp. 75-81
    • Lazzi, G.1
  • 19
    • 34548852907 scopus 로고    scopus 로고
    • Incorporating back telemetry in a full-wave CMOS rectifier for RFID and biomedical applications
    • May
    • S. Atluri and M. Ghovanloo, "Incorporating back telemetry in a full-wave CMOS rectifier for RFID and biomedical applications," in Proc. IEEE Int. Symp. Circuits Syst., May 2007, pp. 801-804.
    • (2007) Proc. IEEE Int. Symp. Circuits Syst , pp. 801-804
    • Atluri, S.1    Ghovanloo, M.2
  • 20
    • 8344259144 scopus 로고    scopus 로고
    • Fully integrated wideband high-current rectifiers for wireless biomedical implants
    • Nov
    • M. Ghovanloo and K. Najafi, "Fully integrated wideband high-current rectifiers for wireless biomedical implants," IEEE J. Solid-State Circuits, vol. 39, no. 11, pp. 1976-1984, Nov. 2004.
    • (2004) IEEE J. Solid-State Circuits , vol.39 , Issue.11 , pp. 1976-1984
    • Ghovanloo, M.1    Najafi, K.2
  • 22
    • 51449094611 scopus 로고    scopus 로고
    • A high efficiency full wave rectifier in standard CMOS technology
    • Aug
    • G. Bawa, U. Jow, and M. Ghovanloo, "A high efficiency full wave rectifier in standard CMOS technology," in IEEE Midwest Symp. Circuits Syst., Aug. 2007, pp. 81-84.
    • (2007) IEEE Midwest Symp. Circuits Syst , pp. 81-84
    • Bawa, G.1    Jow, U.2    Ghovanloo, M.3
  • 23
    • 39549107342 scopus 로고    scopus 로고
    • Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission
    • Sep
    • U. Jow and M. Ghovanloo, "Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission," IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 3, pp. 193-202, Sep. 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst , vol.1 , Issue.3 , pp. 193-202
    • Jow, U.1    Ghovanloo, M.2
  • 24
    • 34247889987 scopus 로고    scopus 로고
    • FeedBack analysis and design of RF power links for low-power bionic systems
    • Mar
    • M. Baker and R. Sarpeshkar, "FeedBack analysis and design of RF power links for low-power bionic systems," IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 1, pp. 28-38, Mar. 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst , vol.1 , Issue.1 , pp. 28-38
    • Baker, M.1    Sarpeshkar, R.2
  • 25
    • 67651052901 scopus 로고    scopus 로고
    • Analysis, design and implementation of a high efficiency fullwave rectifier in standard CMOS technology
    • accepted for publication
    • G. Bawa and M. Ghovanloo, "Analysis, design and implementation of a high efficiency fullwave rectifier in standard CMOS technology," Analog Integr. Circuits Signal Process., accepted for publication.
    • Analog Integr. Circuits Signal Process
    • Bawa, G.1    Ghovanloo, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.