메뉴 건너뛰기




Volumn 216, Issue 2, 2008, Pages 132-139

Model-based identification and diagnosis of a porcine model of induced endotoxic shock with hemofiltration

Author keywords

Cardiovascular system; Endotoxin; Hemofiltration; Integral method; Parameter identification; Septic shock

Indexed keywords

CARDIOVASCULAR SYSTEM;

EID: 56049086839     PISSN: 00255564     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mbs.2008.08.014     Document Type: Article
Times cited : (34)

References (21)
  • 1
    • 0038013891 scopus 로고    scopus 로고
    • Unraveling severe sepsis: why did optimist fail and what's next?
    • Angus D.C., and Crowther M.A. Unraveling severe sepsis: why did optimist fail and what's next?. JAMA 290 2 (2003) 256
    • (2003) JAMA , vol.290 , Issue.2 , pp. 256
    • Angus, D.C.1    Crowther, M.A.2
  • 2
    • 0034958947 scopus 로고    scopus 로고
    • Epidemiology of severe sepsis in the united states: analysis of incidence, outcome, and associated costs of care
    • Angus D.C., Linde-Zwirble W.T., Lidicker J., Clermont G., Carcillo J., and Pinsky M.R. Epidemiology of severe sepsis in the united states: analysis of incidence, outcome, and associated costs of care. Crit. Care Med. 29 7 (2001) 1303
    • (2001) Crit. Care Med. , vol.29 , Issue.7 , pp. 1303
    • Angus, D.C.1    Linde-Zwirble, W.T.2    Lidicker, J.3    Clermont, G.4    Carcillo, J.5    Pinsky, M.R.6
  • 3
    • 0017625281 scopus 로고
    • Arteriovenous haemofiltration: a new and simple method for treatment of over-hydrated patients resistant to diuretics
    • Kramer P., Wigger W., Rieger J., Matthaei D., and Scheler F. Arteriovenous haemofiltration: a new and simple method for treatment of over-hydrated patients resistant to diuretics. Klin. Wochenschr. 55 22 (1977) 1121
    • (1977) Klin. Wochenschr. , vol.55 , Issue.22 , pp. 1121
    • Kramer, P.1    Wigger, W.2    Rieger, J.3    Matthaei, D.4    Scheler, F.5
  • 4
    • 31344444147 scopus 로고    scopus 로고
    • Integral-based identification of patient specific parameters for a minimal cardiac model
    • Hann C.E., Chase J.G., and Shaw G.M. Integral-based identification of patient specific parameters for a minimal cardiac model. Comput. Methods Programs Biomed. 81 2 (2006) 181
    • (2006) Comput. Methods Programs Biomed. , vol.81 , Issue.2 , pp. 181
    • Hann, C.E.1    Chase, J.G.2    Shaw, G.M.3
  • 10
    • 56049107181 scopus 로고    scopus 로고
    • B.W. Smith, Minimal haemodynamic modelling of the heart and circulation for clinical application, Ph.D. Thesis, University of Canterbury, 2004.
    • B.W. Smith, Minimal haemodynamic modelling of the heart and circulation for clinical application, Ph.D. Thesis, University of Canterbury, 2004.
  • 11
    • 0346249699 scopus 로고    scopus 로고
    • Minimal haemodynamic system model including ventricular interaction and valve dynamics
    • Smith B.W., Chase J.G., Nokes R.I., Shaw G.M., and Wake G. Minimal haemodynamic system model including ventricular interaction and valve dynamics. Med. Eng. Phys. 26 2 (2004) 131
    • (2004) Med. Eng. Phys. , vol.26 , Issue.2 , pp. 131
    • Smith, B.W.1    Chase, J.G.2    Nokes, R.I.3    Shaw, G.M.4    Wake, G.5
  • 13
    • 0033838606 scopus 로고    scopus 로고
    • A closed-loop model of the canine cardiovascular system that includes ventricular interaction
    • Olansen J.B., Clark J.W., Khoury D., Ghorbel F., and Bidani A. A closed-loop model of the canine cardiovascular system that includes ventricular interaction. Comput. Biomed. Res. 33 (2000) 260
    • (2000) Comput. Biomed. Res. , vol.33 , pp. 260
    • Olansen, J.B.1    Clark, J.W.2    Khoury, D.3    Ghorbel, F.4    Bidani, A.5
  • 14
    • 79961018753 scopus 로고    scopus 로고
    • T. Desaive, B. Lambermont, A. Ghuysen, P. Kolh, P.C. Dauby, C. Starfinger, C.E. Hann, J.G. Chase, G.M. Shaw, Cardiovascular modelling and identification in septic shock - experimental validation, in: Proceedings of the 17th IFAC World Congress July 6-11, 2008, Seoul, Korea, 2008.
    • T. Desaive, B. Lambermont, A. Ghuysen, P. Kolh, P.C. Dauby, C. Starfinger, C.E. Hann, J.G. Chase, G.M. Shaw, Cardiovascular modelling and identification in septic shock - experimental validation, in: Proceedings of the 17th IFAC World Congress July 6-11, 2008, Seoul, Korea, 2008.
  • 16
    • 0021854779 scopus 로고
    • Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts
    • Burkhoff D., van der Velde E., Kass D., Baan J., Maughan W.L., and Sagawa K. Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts. Circulation 72 2 (1985) 440
    • (1985) Circulation , vol.72 , Issue.2 , pp. 440
    • Burkhoff, D.1    van der Velde, E.2    Kass, D.3    Baan, J.4    Maughan, W.L.5    Sagawa, K.6
  • 20
    • 0022643180 scopus 로고
    • Biventricular function during volume loading in porcine E. coli septic shock, with emphasis on right ventricular function
    • Schneider A.J., Teule G.J., Kester A.D., Heidendal G.A., and Thijs L.G. Biventricular function during volume loading in porcine E. coli septic shock, with emphasis on right ventricular function. Circ. Shock 18 1 (1986) 53
    • (1986) Circ. Shock , vol.18 , Issue.1 , pp. 53
    • Schneider, A.J.1    Teule, G.J.2    Kester, A.D.3    Heidendal, G.A.4    Thijs, L.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.