메뉴 건너뛰기




Volumn 15, Issue 7, 2008, Pages 939-957

Smart system design for a 3D base-isolated benchmark building

Author keywords

Controllability; Hankel singular value; LQG control; MR damper; Placement index

Indexed keywords

BENCHMARK BUILDINGS; BENCHMARK PROBLEMS; CASE STUDIES; COMPLEX SYSTEMS; CONTROL ACTIONS; CONTROL DESIGNS; CONTROL DEVICES; CONTROL TECHNIQUES; CONTROL TECHNOLOGIES; HANKEL SINGULAR VALUE; ISOLATED BUILDINGS; ISOLATION SYSTEMS; LQG CONTROL; LQG CONTROL ALGORITHMS; MAGNETORHEOLOGICAL DAMPERS; MR DAMPER; NATURAL HAZARDS; OPTIMAL DECISIONS; PASSIVE ISOLATORS; PHASE I; PLACEMENT INDEX; SEMIACTIVE DEVICES; SENSOR PLACEMENTS; SIMULATION RESULTS; SMART BASE ISOLATIONS; SMART SYSTEMS; STRUCTURAL PERFORMANCES;

EID: 55749087500     PISSN: 15452255     EISSN: 15452263     Source Type: Journal    
DOI: 10.1002/stc.228     Document Type: Article
Times cited : (17)

References (39)
  • 3
    • 0042801873 scopus 로고
    • Secondary systems in base-isolated structures: Experimental investigation, stochastic response and stochastic sensitivity
    • Technical Report NCEER-90-0013, State University of New York at Buffalo, July
    • Manolis G, Juhn G, Constantinou M, Reinhorn A. Secondary systems in base-isolated structures: experimental investigation, stochastic response and stochastic sensitivity. Technical Report NCEER-90-0013, State University of New York at Buffalo, July, 1990.
    • (1990)
    • Manolis, G.1    Juhn, G.2    Constantinou, M.3    Reinhorn, A.4
  • 5
    • 0034298444 scopus 로고    scopus 로고
    • Response of base-isolated USC hospital building in Northridge earthquake
    • Nagarajaiah S, Xiaohong S. Response of base-isolated USC hospital building in Northridge earthquake. Journal of Structural Engineering (ASCE) 2000; 126(10):1177-1186.
    • (2000) Journal of Structural Engineering (ASCE) , vol.126 , Issue.10 , pp. 1177-1186
    • Nagarajaiah, S.1    Xiaohong, S.2
  • 7
    • 0024471369 scopus 로고
    • Seismic response of the superstructure and attached equipment in a base-isolated building
    • Tsai HC, Kelly JM. Seismic response of the superstructure and attached equipment in a base-isolated building. Earthquake Engineering and Structural Dynamics 1989; 18:551-564.
    • (1989) Earthquake Engineering and Structural Dynamics , vol.18 , pp. 551-564
    • Tsai, H.C.1    Kelly, J.M.2
  • 11
    • 0034255331 scopus 로고    scopus 로고
    • Semi-active control strategies for the MR damper: A comparative study
    • Jansen LM, Dyke SJ, Semi-active control strategies for the MR damper: a comparative study. Journal of Engineering Mechanics 2000; 126(8):795-803.
    • (2000) Journal of Engineering Mechanics , vol.126 , Issue.8 , pp. 795-803
    • Jansen, L.M.1    Dyke, S.J.2
  • 12
    • 27644557979 scopus 로고    scopus 로고
    • Investigation of nonlinear control strategies for the implementation of multiple magnetorheological dampers
    • Baltimore, ML, June 16
    • Jansen LM, Dyke SJ. Investigation of nonlinear control strategies for the implementation of multiple magnetorheological dampers. Proceedings of the 1999 ASCE Engineering Mechanics Conference, Baltimore, ML, June 16, 1999.
    • (1999) Proceedings of the 1999 ASCE Engineering Mechanics Conference
    • Jansen, L.M.1    Dyke, S.J.2
  • 15
  • 16
    • 18144430291 scopus 로고    scopus 로고
    • Response control of full scale irregular buildings using MR dampers
    • Yoshida O, Dyke SJ. Response control of full scale irregular buildings using MR dampers, Journal of Structural Engineering 2005; 131(5):734-742.
    • (2005) Journal of Structural Engineering , vol.131 , Issue.5 , pp. 734-742
    • Yoshida, O.1    Dyke, S.J.2
  • 18
    • 33847706985 scopus 로고    scopus 로고
    • Passive and hybrid control systems for seismic protection of a benchmark cable-stayed bridge
    • He WL, Agrawal AK. Passive and hybrid control systems for seismic protection of a benchmark cable-stayed bridge. Journal of Structural Control and Health Monitoring 2005; 14(1):1-26.
    • (2005) Journal of Structural Control and Health Monitoring , vol.14 , Issue.1 , pp. 1-26
    • He, W.L.1    Agrawal, A.K.2
  • 21
    • 0036605238 scopus 로고    scopus 로고
    • Selective controlled base isolation system with magnetorheological dampers
    • Ribakov Y, Gluck J. Selective controlled base isolation system with magnetorheological dampers. Earthquake Engineering and Structural Dynamics 2002; 31:1301-1324.
    • (2002) Earthquake Engineering and Structural Dynamics , vol.31 , pp. 1301-1324
    • Ribakov, Y.1    Gluck, J.2
  • 26
    • 55749089414 scopus 로고    scopus 로고
    • Smart base isolated benchmark building part a sample controller for bilinear isolation
    • DOI: 10.1002/stc.101
    • Erkus B, Johnson EA. Smart base isolated benchmark building part a sample controller for bilinear isolation. Journal of Structural Control and Health Monitoring 2004; DOI: 10.1002/stc.101.
    • (2004) Journal of Structural Control and Health Monitoring
    • Erkus, B.1    Johnson, E.A.2
  • 28
    • 0031147699 scopus 로고    scopus 로고
    • Rigidity-plasticity-viscosity: Can electrorheological damper protect base-isolated structures from near-source ground motions?
    • Makris N. Rigidity-plasticity-viscosity: can electrorheological damper protect base-isolated structures from near-source ground motions? Earthquake Engineering and Structural Dynamics 1997; 26(5):571-591.
    • (1997) Earthquake Engineering and Structural Dynamics , vol.26 , Issue.5 , pp. 571-591
    • Makris, N.1
  • 29
    • 4544348762 scopus 로고    scopus 로고
    • Efficiency of a simple approach to damper allocation in MDOF structures
    • Lopez G, Soong TT. Efficiency of a simple approach to damper allocation in MDOF structures, Journal of Structural Control 2002; 9(1):19-30.
    • (2002) Journal of Structural Control , vol.9 , Issue.1 , pp. 19-30
    • Lopez, G.1    Soong, T.T.2
  • 30
    • 0031282126 scopus 로고    scopus 로고
    • Optimal damper placement for minimum transfer function
    • Takewaki I. Optimal damper placement for minimum transfer function. Earthquake Engineering and Structural Dynamics' 1997; 26(11):1113-1124.
    • (1997) Earthquake Engineering and Structural Dynamics , vol.26 , Issue.11 , pp. 1113-1124
    • Takewaki, I.1
  • 31
    • 0036605662 scopus 로고    scopus 로고
    • Optimal design of active/passive control devices for tall buildings under earthquake excitation
    • Xu YL, Teng J. Optimal design of active/passive control devices for tall buildings under earthquake excitation. Structural Design of Tall Buildings 2002; 11(2):109-127.
    • (2002) Structural Design of Tall Buildings , vol.11 , Issue.2 , pp. 109-127
    • Xu, Y.L.1    Teng, J.2
  • 32
    • 0033082898 scopus 로고    scopus 로고
    • Optimal placement of DVFC controllers on buildings subjected to earthquake loading
    • Abdullah MM. Optimal placement of DVFC controllers on buildings subjected to earthquake loading. Earthquake Engineering and Structural Dynamics 1999; 28(2):127-141.
    • (1999) Earthquake Engineering and Structural Dynamics , vol.28 , Issue.2 , pp. 127-141
    • Abdullah, M.M.1
  • 34
    • 13844262588 scopus 로고    scopus 로고
    • Wongprasert N, Symms MD. Application of a genetic algorithm for optimal damper distribution within the nonlinear seismic benchmark building. Journal of Engineering Mechanics (ASCE), Special Issue on Structural Control Benchmark Problems for Dynamically Excited Buildings 2004; 130(4):401-406.
    • Wongprasert N, Symms MD. Application of a genetic algorithm for optimal damper distribution within the nonlinear seismic benchmark building. Journal of Engineering Mechanics (ASCE), Special Issue on Structural Control Benchmark Problems for Dynamically Excited Buildings 2004; 130(4):401-406.
  • 35
    • 0021529179 scopus 로고
    • Number and placement of control system components considering possible failures
    • Vander Velde WE, Carignan CR. Number and placement of control system components considering possible failures. Journal of Guidance, Control and Dynamics 1984; 7(6):703-709.
    • (1984) Journal of Guidance, Control and Dynamics , vol.7 , Issue.6 , pp. 703-709
    • Vander Velde, W.E.1    Carignan, C.R.2
  • 36
    • 0021786337 scopus 로고
    • Optimal actuators placement for the active control of flexible structures
    • Ibidapo O. Optimal actuators placement for the active control of flexible structures. Journal of Mathematical Analysis and Applications 1985; 105(1):12-25.
    • (1985) Journal of Mathematical Analysis and Applications , vol.105 , Issue.1 , pp. 12-25
    • Ibidapo, O.1
  • 37
    • 0031650814 scopus 로고    scopus 로고
    • Balanced shaker and sensor placement for modal testing of large flexible structures
    • Santa Barbara, CA
    • Panossian H, Gawronski W, Ossman J. Balanced shaker and sensor placement for modal testing of large flexible structures. Proceedings of the IMAC-XVI; Santa Barbara, CA, 1998.
    • (1998) Proceedings of the IMAC-XVI
    • Panossian, H.1    Gawronski, W.2    Ossman, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.