메뉴 건너뛰기




Volumn 52, Issue 5, 2008, Pages 517-524

Assessment of a daily online implanted fiducial marker-guided prostate radiotherapy process

Author keywords

Physics; Quality assurance; Radiation oncology imaging

Indexed keywords

ACCURACY; ARTICLE; BODY MOVEMENT; BODY POSITION; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; CONTROLLED STUDY; HUMAN; IMPLANTATION; MALE; MEDICAL ERROR; PRIORITY JOURNAL; PROSTATE CANCER; QUALITY CONTROL; TREATMENT DURATION;

EID: 55649104703     PISSN: 17549477     EISSN: 17549485     Source Type: Journal    
DOI: 10.1111/j.1440-1673.2008.02006.x     Document Type: Article
Times cited : (6)

References (16)
  • 1
    • 0028843714 scopus 로고
    • Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility
    • Balter JM, Lam KL, Sandler HM et al. Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility. Int J Radiat Oncol Biol Phys 1995 33 : 1281 6.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1281-6
    • Balter, J.M.1    Lam, K.L.2    Sandler, H.M.3
  • 2
    • 0027527197 scopus 로고
    • Localization of the prostatic apex for radiation therapy using implanted markers
    • Sandler HM, Bree RL, McLaughlin PW et al. Localization of the prostatic apex for radiation therapy using implanted markers. Int J Radiat Oncol Biol Phys 1993 27 : 915 19.
    • (1993) Int J Radiat Oncol Biol Phys , vol.27 , pp. 915-19
    • Sandler, H.M.1    Bree, R.L.2    McLaughlin, P.W.3
  • 3
    • 0037966410 scopus 로고    scopus 로고
    • Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation
    • Dehnad H, Nederveen AJ, Van Der Heide UA et al. Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation. Radiother Oncol 2003 67 : 295 302.
    • (2003) Radiother Oncol , vol.67 , pp. 295-302
    • Dehnad, H.1    Nederveen, A.J.2    Van Der Heide, U.A.3
  • 4
    • 0036223115 scopus 로고    scopus 로고
    • Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    • Kitamura K, Shirato H, Shimizu S et al. Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Radiother Oncol 2002 62 : 275 81.
    • (2002) Radiother Oncol , vol.62 , pp. 275-81
    • Kitamura, K.1    Shirato, H.2    Shimizu, S.3
  • 5
    • 0038210245 scopus 로고    scopus 로고
    • (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging device
    • Pouliot J, Aubin M, Langen KM et al. (Non)-migration of radiopaque markers used for on-line localization of the prostate with an electronic portal imaging device. Int J Radiat Oncol Biol Phys 2003 56 : 862 6.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 862-6
    • Pouliot, J.1    Aubin, M.2    Langen, K.M.3
  • 6
    • 22144456659 scopus 로고    scopus 로고
    • Intraprostatic fiducials for localization of the prostate gland: Monitoring intermarker distances during radiation therapy to test for marker stability
    • Kupelian PA, Willoughby TR, Meeks SL et al. Intraprostatic fiducials for localization of the prostate gland: Monitoring intermarker distances during radiation therapy to test for marker stability. Int J Radiat Oncol Biol Phys 2005 62 : 1291 6.
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 1291-6
    • Kupelian, P.A.1    Willoughby, T.R.2    Meeks, S.L.3
  • 7
    • 25844451193 scopus 로고    scopus 로고
    • Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging
    • Schallenkamp JM, Herman MG, Kruse JJ et al. Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging. Int J Radiat Oncol Biol Phys 2005 63 : 800 11.
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 800-11
    • Schallenkamp, J.M.1    Herman, M.G.2    Kruse, J.J.3
  • 8
    • 33846211921 scopus 로고    scopus 로고
    • Analysis of fiducial marker-based position verification in the external beam radiotherapy of patients with prostate cancer
    • van der Heide UA, Kotte ANTJ, Dehnad H et al. Analysis of fiducial marker-based position verification in the external beam radiotherapy of patients with prostate cancer. Radiother Oncol 2007 82 : 38 45.
    • (2007) Radiother Oncol , vol.82 , pp. 38-45
    • Van Der Heide, U.A.1    Antj, K.2    Dehnad, H.3
  • 9
    • 0345689460 scopus 로고    scopus 로고
    • Intrafractional stability of the prostate using a stereotactic radiotherapy technique
    • Madsen BL, Hsi RA, Pham HT et al. Intrafractional stability of the prostate using a stereotactic radiotherapy technique. Int J Radiat Oncol Biol Phys 2003 57 : 1285 91.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1285-91
    • Madsen, B.L.1    Hsi, R.A.2    Pham, H.T.3
  • 10
    • 4444270625 scopus 로고    scopus 로고
    • Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers
    • Aubry JF, Beaulieu L, Girouard LM et al. Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers. Int J Radiat Oncol Biol Phys 2004 60 : 30 39.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 30-39
    • Aubry, J.F.1    Beaulieu, L.2    Girouard, L.M.3
  • 11
    • 0036569622 scopus 로고    scopus 로고
    • Et al. Measurements and clinical consequences of prostate motion during a radiotherapy fraction
    • Nederveen AJ, van der Heide UA, Dehnad H et al. Measurements and clinical consequences of prostate motion during a radiotherapy fraction. Int J Radiat Oncol Biol Phys 2002 53 : 206 14.
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 206-14
    • Nederveen, A.J.1    Van Der Heide, U.A.2    Dehnad, H.3
  • 12
    • 33646487136 scopus 로고    scopus 로고
    • Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer
    • Willoughby TR, Kupelian PA, Pouliot J et al. Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. Int J Radiat Oncol Biol Phys 2006 65 : 528 34.
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 528-34
    • Willoughby, T.R.1    Kupelian, P.A.2    Pouliot, J.3
  • 13
    • 21044457706 scopus 로고    scopus 로고
    • Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)
    • Ghilezan MJ, Jaffray DA, Siewerdsen JH et al. Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). Int J Radiat Oncol Biol Phys 2005 62 : 406 17.
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 406-17
    • Ghilezan, M.J.1    Jaffray, D.A.2    Siewerdsen, J.H.3
  • 14
    • 0142043343 scopus 로고    scopus 로고
    • Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials
    • Nederveen AJ, Dehnad H, Van Der Heide UA et al. Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials. Radiother Oncol 2003 68 : 81 8.
    • (2003) Radiother Oncol , vol.68 , pp. 81-8
    • Nederveen, A.J.1    Dehnad, H.2    Van Der Heide, U.A.3
  • 15
    • 0142186646 scopus 로고    scopus 로고
    • Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device
    • Herman MG, Pisansky TM, Kruse JJ et al. Technical aspects of daily online positioning of the prostate for three-dimensional conformal radiotherapy using an electronic portal imaging device. Int J Radiat Oncol Biol Phys 2003 57 : 1131 40.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1131-40
    • Herman, M.G.1    Pisansky, T.M.2    Kruse, J.J.3
  • 16
    • 4444285372 scopus 로고    scopus 로고
    • On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma
    • Chung PWM, Haycocks T, Brown T et al. On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma. Int J Radiat Oncol Biol Phys 2004 60 : 329 34.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 329-34
    • Chung, P.W.M.1    Haycocks, T.2    Brown, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.